XZXiaohong Zheng

Xiaohong Zheng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xiaohong Zheng has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Concise Grid-Based Model Revealing the Temporal Dynamics in Indoor Infection Risk

    by Pengcheng Zhao, Xiaohong Zheng

    Determining the transmission routes of pathogens in indoor environments is challenging, with most studies limited to specific case analyses and pilot experiments. When pathogens are instantaneously released by a patient in an indoor environment, the peak infection risk may not occur immediately but may instead appear at a specific moment during the pathogen’s spread. We developed a concise model to describe the temporal crest of infection risk. The model incorporates the transmission and degradation characteristics of aerosols and surface particles to predict infection risks via air and surface routes. Only four real-world outbreaks met the criteria for validating this phenomenon. Based on the available data, norovirus is likely to transmit primarily via surface touch (i.e., the fomite route). In contrast, crests of infection risk were not observed in outbreaks of respiratory diseases (e.g., SARS-CoV-2), suggesting a minimal probability of surface transmission in such cases. The new model can serve as a preliminary indicator for identifying different indoor pathogen transmission routes (e.g., food, air, or fomite). Further analyses of pathogens’ transmission routes require additional evidence.


  • Open Access

    Assessment on the Impact Factors of Outdoor Thermal Comfort Among the Elderly Across Diverse Climate Zones in China

    by Jianing Fu, Hua Qian, Chenxue Song, Pengcheng Zhao, Ruotong Wang, Zhelin Li, Xiaohong Zheng


  • Positive or negative? The pressure control impact in hybrid ventilated hospitals

    by Kai Lu, Zhen Ding, Hua Qian, Xiaohong Zheng

    The outbreak of coronavirus disease 2019 (COVID-19) has had a significant impact on human life. Hybrid ventilated hospitals have emerged as multi-zone sites, necessitating ventilation strategies to mitigate viral concentration. This paper integrates multi-zone infiltration and exfiltration (MIX) model of natural ventilation, spatial flow impact factor (SFIF) model and pollutant concentration model to analyze the inter-zonal impact. Results indicate that elevated outdoor temperature corresponds to an increased influence of rooms on corridors. Adopting mechanical ventilation in rooms diminishes the influence of room pollutants on corridors but exerts minimal impact on other rooms. Mechanical air supply reduces the interaction between corridors, and the reduction is most significant when wind direction is the same as stairwell orientation. The corridors do not affect the upstream rooms when the source is in the corridor. When wind speed is below a threshold, mechanical air supply is recommended; for wind speed reaching this threshold, mechanical air exhaust volumes should be adjusted regarding the wind speed. The study reveals that corridor and room window openings exert disparate effects on corridor concentration under mechanical air supply conditions. All the findings offer valuable insights for selecting ventilation strategies in hybrid ventilated hospitals, with the aim of mitigating COVID-19 transmission.

  • Study on the effect of humidity on formaldehyde emission parameters of wood-based panels

    by Jiani Chen, Xiaohong Zheng, Chenxue Song, Hua Qian

    Wood-based panels are a significant source of indoor volatile organic compounds (VOCs), crucial for managing indoor pollution. The emissions from wood-based panels are influenced by both intrinsic factors, including their composition and manufacturing process, and extrinsic environmental conditions, such as temperature and humidity. In this paper, the emission of formaldehyde in plywood was studied under different temperature conditions (15°C, 23°C, 32°C and 37°C) and different humidity conditions (40%, 60% and 80%) by environmental chamber method. To understand the influence of relative humidity on the key parameters of panels from a mechanism perspective, this paper investigates the influence of relative humidity on the initial emittable concentration of formaldehyde, based on the hydrolysis reaction of urea-formaldehyde resin. Concurrently, the molecular dynamics and porous panels model were amalgamated to assess the influence of relative humidity on both the partition and diffusion coefficient. To simulate the emission process in a real environment, a control equation that allows for variations in both temperature and humidity is needed. This paper employs the method of variable separation to derive a simplified control equation. Subsequently, experimental data was utilized to validate the derived equation’s effectiveness within the practical indoor environmental range.


  • Can air handling equipment be beneficial to children’s health? Results from a cross-sectional survey in 2010 and 2019 in China

    by Yawei Xu, Xiaohong Zheng, Zhuohui Zhao, Hua Qian

    A growing number of studies have shown that the indoor residential environment is associated with respiratory and allergic diseases in children. This study aimed to investigate the prevalence of respiratory and allergic diseases among children in China and its correlation with using air handling equipment, based on the cross-sectional survey results of the China Children Homes Health Project in 2010 and 2019. The binary logistic regression model was used to explore the association between asthma, rhinitis, eczema and pneumonia and the use of air handling equipment in children. The prevalence of children’s respiratory and allergic diseases has decreased, and the usage rate of portable air purifiers and split air conditioners has increased in 2019 compared to 2010. The results showed that using a fresh air system with filters was negatively correlated with children’s pneumonia (adjusted odds ratio (aOR): 0.767, 95% confidence interval (95% CI): 0.704–0.835). The use of portable air purifiers was positively correlated with most diseases’ symptoms in two undertaken surveys. In 2019, the positive correlation between using split air conditioners and asthma-related symptoms decreased compared with 2010, while it was positively correlated with rhinitis, eczema and pneumonia. To avoid children’s allergic diseases and reduce respiratory symptoms, parents should choose appropriate air handling equipment.


  • Open Access

    Dental professionals' use of personal protective equipment during COVID-19: a cross-sectional study in China

    by Qinjie Wan, Lei Han, Xin Yang, Shaoling Yu, Xiaohong Zheng

    Background: Appropriate use of personal protective equipment (PPE) could significantly reduce the risk of viral transmission and infection. This study aimed to assess the use of PPE among dentists during the COVID-19 pandemic in China, explore its influencing factors, and provide some practical recommendations.Methods: An online cross-sectional survey was conducted among 384 Chinese dentists in September 2022. The questionnaire comprised a series of questions about demographic characteristics, compliance with proper PPE use, personal barriers to use, and exposure risk estimation.Results: Of the 384 respondents, 57.3% had unacceptable compliance with the proper use of PPE during COVID-19. Medical surgical mask is the most common for dental professionals to wear (93.8%), followed by goggles or face shield (63.8%), and isolation gown (53.1%). Unexpectedly, only 63.3% of respondents always change masks with guidelines. The condition for changing goggles/face shields and isolation gowns is even worse (45.6 and 37.0%, respectively). Visual barriers, physical discomfort, complex procedures, and heavy workload were the most common personal barriers to use. According to the results of Chi-square test and correlation analysis, PPE use compliance was associated with age, years of practice, medical institution type, and exposure risk estimation.Conclusion: Chinese dental professionals need to improve their compliance with the proper use of PPE, especially those in the 31–40 age group, with 11–15 experience years and working in private dental clinics. Increasing compliance with PPE may be achieved by addressing personal barriers to use, human resource shortages, and perceptions of exposure risk.


  • Open Access

    Study on Interparticle Interaction Force Model to Correct Saturation Density of Real Cryogenic Fluid for LBM Simulation

    by Wenqing Liang, Zhiyong Shu, Fuming Lu, Yong Wang, Xiaohong Zheng, Hua Qian

    Cryogenic liquefaction energy storage is an important form of storage for sustainable energy liquid hydrogen and other gases. The weighting parameter A in the parameter-adjusted two-phase LBM model is important for the deviation of simulation results. The aim of this paper is to discover the appropriate parameter to eliminate the deviation, and to solve the problem of large deviation between the theoretical solution and the simulated value that is caused by using different equations of state in LBM simulation. The modified PT equation of state, which is suitable for cryogenic fluids, is combined with the parameter-adjustable two-phase model to simulate the saturation density at different temperatures. Four typical cryogenic fluids—nitrogen, hydrogen, oxygen, and helium—are exploratively simulated to find the suitable parameters to eliminate errors by analyzing the results with theoretical solutions. This is an efficient solution to the deviation between the simulated value and the theoretical solutions, which is caused by the different equation of state in LBM. The optimal A-value of the model based on the PT equation of state was obtained as −0.21, while droplets and bubbles were set into the calculation region, and an inverse relationship between the interface density gradient and temperature was analyzed. The analysis and comparison of the simulation results under the optimal value and the experimental values have laid an important foundation for the phase change simulation of the real cryogenic fluids at the mesoscopic scale.


  • Open Access

    Exposure Risk to Medical Staff in a Nasopharyngeal Swab Sampling Cabin under Four Different Ventilation Strategies

    by Jianchao Ma, Hua Qian, Fan Liu, Guodong Sui, Xiaohong Zheng

    Medical staff working in a nasopharyngeal swab sampling cabin are exposed to a higher exposure risk of COVID-19. In this study, computational fluid dynamics (CFD) are used to evaluate the exposure risk to medical staff in a nasopharyngeal swab sampling cabin of Chinese customs under four different ventilation strategies, i.e., multiple supply fans ventilation (MSFV), multiple exhaust fans ventilation (MEFV), single exhaust fan and outer windows closed ventilation (SEFV), and single exhaust fan and outer windows opened ventilation (SEFV-W). The impact of physical partitions on exposure risk is also discussed. The results show that MSFV performed best in reducing exposure risk. No significant difference was found between MEFV and SEFV. SEFV-W performed better than SEFV with a ventilation rate of 10–50 L/(s∙Person), while it performed worse with a ventilation rate of 50–90 L/(s∙Person). The exposure risk to medical staff did not decrease linearly with the increase in the ventilation flow rate under the four ventilation strategies. For MSFV, the installation of partitions is conducive to the reduction in the exposure risk. This study is expected to provide some guidance for ventilation designs in sampling cabins.


  • Open Access

    Indoor transmission of SARS-CoV-2

    by Hua Qian, Te Miao, Li Liu, Xiaohong Zheng, Danting Luo, Yuguo Li

    Background: By early April 2020, the COVID-19 pandemic had infected nearly one million people and had spread to nearly all countries worldwide. It is essential to understand where and how SARS-CoV-2 is transmitted. Methods: Case reports were extracted from the local Municipal Health Commissions of 320 prefectural cities (municipalities) in China, not including Hubei province, between 4 January and 11 February 2020. We identified all outbreaks involving three or more cases and reviewed the major characteristics of the enclosed spaces in which the outbreaks were reported and associated indoor environmental issues. Results: Three hundred and eighteen outbreaks with three or more cases were identified, involving 1245 confirmed cases in 120 prefectural cities. We divided the venues in which the outbreaks occurred into six categories: homes, transport, food, entertainment, shopping, and miscellaneous. Among the identified outbreaks, 53·8% involved three cases, 26·4% involved four cases, and only 1·6% involved ten or more cases. Home outbreaks were the dominant category (254 of 318 outbreaks; 79·9%), followed by transport (108; 34·0%; note that many outbreaks involved more than one venue category). Most home outbreaks involved three to five cases. We identified only a single outbreak in an outdoor environment, which involved two cases. Conclusions: All identified outbreaks of three or more cases occurred in an indoor environment, which confirms that sharing indoor space is a major SARS-CoV-2 infection risk. Funding: The work was supported by the Research Grants Council of Hong (no 17202719, C7025-16G), and National Natural Science Foundation of China (no 41977370).


  • Open Access

    Plum Rain-Season-Oriented Modelling and Intervention of Indoor Humidity with and without Human Occupancy

    by Jin Ye, Hua Qian, Xiaohong Zheng, Guoqing Cao

    The plum rain season, caused by precipitation along a persistent stationary Mei-Yu front in East Asia, creates favorable temperatures and relative humidity (RH) for mold growth indoors. This paper investigates the effects of human occupancy on indoor humidity and investigates the efficient RH reduction methods to prevent mold growth in moist climates. The research is carried out based on a case study which compares a family-occupied home and another unoccupied one during typical plum rain season in Nanjing. Firstly, by analyzing the factors that can influence the indoor air RH, this paper develops a comprehensive model to evaluate the efficiency of various RH intervention methods. Secondly, this paper collects the meteorological data in Nanjing at different time scales, from days to hours. Thirdly, a specific case study is carried out based on the model and data. The results show that dehumidification and heating can always reduce RH below the critical value under which the mold growth could be inhibited. However, the effects of ventilation are more sophisticated and depend upon the human occupancy, outdoor air temperature, and air change per hour (ACH). In certain unoccupied cases, the ventilation may be inappropriate and may continuously bring moisture outside into the indoor environment, which has adverse effects on mold suppression. In the occupied cases, the condition changes significantly because the human is deemed as an internal source of heat and moist. Special care should be exercised for occupied ventilation in order to determine the optimal ACH and appropriate outdoor temperatures. Finally, some guidance is given to prevent mold growth in the general area that suffers from the plum rain season.