Xiulian Dmd Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiulian Dmd Hu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Hui Wu
1 shared publicationJian-Hui Li
1 shared publication- Ping Di
Department of Oral Implantology, Peking University School and Hospital of Stomatology, Beijing 100081, China
1 shared publication Xian Zhou
Master Degree Candidate, Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, Beijing, China
1 shared publicationYe Dmd Lin
Professor, Department of Oral Implantology, Peking University School and Hospital of Stomatology, Beijing, China
1 shared publicationYe Lin
1 shared publication
Latest Publications
- 1 April 2018
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 27 (2) , 202-208
Coating of Sandblasted and Acid-Etched Dental Implants With Tantalum Using Vacuum Plasma Spraying
Purpose: The objective was to prepare tantalum (Ta)-coated sandblasted and acid-etched (SLA) dental implants using vacuum plasma spraying (VPS) and to analyze their morphologies. Materials and Methods: Twelve SLA implants were coated with Ta using VPS. The topographies of the coatings and Ta/SLA surface interfaces were examined using scanning electron microscopy. The thickness at 4 locations for 6 Ta-coated and 6 uncoated SLA implants and pore sizes of the neck, central, and root areas of Ta-coated implants were measured. SPSS v20.0 was used for statistical analysis. Results: The Ta coatings were rough and consisted of pitted structures with various pore sizes; no cracks were observed. The Ta/SLA surface interface was tightly bonded. The 95% confidence interval of the Ta coating thickness was (114.0759, 129.3574). The maximal pore diameter was concentrated at 200 to 400 nm. Conclusion: SLA dental implants were successfully coated with Ta using VPS. The nanoporous structure of these implants may facilitate osseointegration compared with uncoated SLA implants.
- 1 April 2018
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 27 (2) , 202-208
Coating of Sandblasted and Acid-Etched Dental Implants With Tantalum Using Vacuum Plasma Spraying
Purpose: The objective was to prepare tantalum (Ta)-coated sandblasted and acid-etched (SLA) dental implants using vacuum plasma spraying (VPS) and to analyze their morphologies. Materials and Methods: Twelve SLA implants were coated with Ta using VPS. The topographies of the coatings and Ta/SLA surface interfaces were examined using scanning electron microscopy. The thickness at 4 locations for 6 Ta-coated and 6 uncoated SLA implants and pore sizes of the neck, central, and root areas of Ta-coated implants were measured. SPSS v20.0 was used for statistical analysis. Results: The Ta coatings were rough and consisted of pitted structures with various pore sizes; no cracks were observed. The Ta/SLA surface interface was tightly bonded. The 95% confidence interval of the Ta coating thickness was (114.0759, 129.3574). The maximal pore diameter was concentrated at 200 to 400 nm. Conclusion: SLA dental implants were successfully coated with Ta using VPS. The nanoporous structure of these implants may facilitate osseointegration compared with uncoated SLA implants.
- 1 April 2008
- Vol. 43 (4) , 226-9
[Clinical study of sinus elevation by water balloon and implant placement].
To evaluate the clinical results and technique of minimally invasive sinus membrane water balloon elevation followed by bone augmentation and implant placement simultaneously. From May 2006 to November 2007, 31 patients (male: 16, female: 15; mean age: 41.2 +/- 11.8) were involved in the study. Clinical examination and radiographs were conducted. The mean residual ridge height was (4.79 +/- 1.18) mm and the mean elevated height was (10.60 +/- 2.06) mm. A total of 31 implants were placed and restored with the mean follow-up period of (14.2 +/- 3.6) months. Only minor complications were observed postoperatively. One implant was lost due to infection two weeks after operation. The procedure of minimally invasive sinus membrane water balloon elevation achieves an excellent success rate, low complication, minimal discomfort, and the short-term result is predictable.
- 1 April 2008
- Vol. 43 (4) , 226-9
[Clinical study of sinus elevation by water balloon and implant placement].
To evaluate the clinical results and technique of minimally invasive sinus membrane water balloon elevation followed by bone augmentation and implant placement simultaneously. From May 2006 to November 2007, 31 patients (male: 16, female: 15; mean age: 41.2 +/- 11.8) were involved in the study. Clinical examination and radiographs were conducted. The mean residual ridge height was (4.79 +/- 1.18) mm and the mean elevated height was (10.60 +/- 2.06) mm. A total of 31 implants were placed and restored with the mean follow-up period of (14.2 +/- 3.6) months. Only minor complications were observed postoperatively. One implant was lost due to infection two weeks after operation. The procedure of minimally invasive sinus membrane water balloon elevation achieves an excellent success rate, low complication, minimal discomfort, and the short-term result is predictable.