Hongda Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hongda Tang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Biao Tang
Electric Power Research Institute of Yunnan Power Grid Co., Ltd., Kunming 650200, China
1 shared publication - Fang Zeng
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication - Hongchun Shu
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication - Mengmeng Zhu
Electric Power Research Institute of Yunnan Power Grid Co., Ltd., Kunming 650200, China
1 shared publication - Pulin Cao
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication - Qunqun Zhang
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication
Latest Publications
- Open Access
Field Test Method and Equivalence Analysis of Delay Characteristics of DC Electronic Current Transformer
DC electronic current transformer is the data source of the system control and protection device, so its measurement delay has always been concerned. In this paper, the DC current transformer is modelled equivalently and the key factors affecting the delay of shunt and the remote module are analyzed. A field test method for the delay characteristics of the DC electronic current transformer is proposed. Moreover, a complex multi-state large current generator and integrated test system are developed. On the basis of the IEC 60044-8 standard transmission protocol, the accuracy of standard signal acquisition with the shunt is better than 0.2%. The maximum output current of the established testing system is 600 A. Based on the field test in an actual HVDC project, transient step and various frequency signal components are applied for analyzing.
Open AccessField Test Method and Equivalence Analysis of Delay Characteristics of DC Electronic Current Transformer
DC electronic current transformer is the data source of the system control and protection device, so its measurement delay has always been concerned. In this paper, the DC current transformer is modelled equivalently and the key factors affecting the delay of shunt and the remote module are analyzed. A field test method for the delay characteristics of the DC electronic current transformer is proposed. Moreover, a complex multi-state large current generator and integrated test system are developed. On the basis of the IEC 60044-8 standard transmission protocol, the accuracy of standard signal acquisition with the shunt is better than 0.2%. The maximum output current of the established testing system is 600 A. Based on the field test in an actual HVDC project, transient step and various frequency signal components are applied for analyzing.