Nattida Chokwattanapornchai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nattida Chokwattanapornchai has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Katanyoo Limchaikul
Department of Conservative and Prosthodontics, Faculty of Dentistry, Srinakharinwirot University, Bangkok 10110, Thailand
1 shared publication - Sirichan Chiaraputt
School of Dentistry, King Mongkut's Institute of Technology, Ladkrabang (KMITL), Bangkok, Thailand
1 shared publication - Tool Sriamporn
Department of Prosthodontics, College of Dental Medicine, Rangsit University, Pathum Thani, Thailand
1 shared publication - Vibul Paisarnkobrit
Department of Conservative and Prosthodontics, Faculty of Dentistry, Srinakharinwirot University, Bangkok 10110, Thailand
1 shared publication
Latest Publications
- Open Access
- 29 July 2023
- Published by Wiley in International Journal of Dentistry
- Vol. 2023, 1-7
Effect of Gingival Hemostatic Agents on the Surface Detail Reproduction and Dimension Stability of Three Elastomeric Impression Materials
This study aimed to evaluate the effects of aluminum chloride based hemostatic agents on the surface detail reproduction and dimension stability. Three impression materials were investigated after contaminated with three commercial astringents with different concentration of aluminum chloride. The specimens from three impression materials were fabricated with a stainless-steel mold that followed the American Dental Association specification no.19. The mold was preliminarily contaminated with three hemostatic agents racestyptine, Dryz, and Expasyl™—and 80 specimens from each impression material—polyvinylsiloxane (PVS), polyether, and polyvinylsiloxane ether (PVSE), were fabricated and subjected to each astringent. The surface detail reproduction was examined using a stereomicroscope at 4x magnification, and the dimensional stability was analyzed at 24 hr with a measuring microscope. The surface detail data were statistically analyzed with Fisher’s test at a significance level of 0.05. The dimensional stability data were analyzed using two-way ANOVA and Tukey’s test at a significance level of 0.05. Aluminum chloride hemostatic agents can affect the surface detail reproduction of impression materials differently ( ). Thus, the first null hypothesis was rejected. PVS showed the highest percentage of satisfactory surface detail regardless of the hemostatic agent used in this study. PVSE showed a reduced percentage of satisfactory surface detail when the concentration of aluminum chloride was high. The three hemostatic agents affected the dimensional stability of each material differently ( ). Therefore, the second null hypothesis was also rejected.
- 29 July 2023
- Published by Wiley in International Journal of Dentistry
- Vol. 2023, 1-7
Open AccessEffect of Gingival Hemostatic Agents on the Surface Detail Reproduction and Dimension Stability of Three Elastomeric Impression Materials
This study aimed to evaluate the effects of aluminum chloride based hemostatic agents on the surface detail reproduction and dimension stability. Three impression materials were investigated after contaminated with three commercial astringents with different concentration of aluminum chloride. The specimens from three impression materials were fabricated with a stainless-steel mold that followed the American Dental Association specification no.19. The mold was preliminarily contaminated with three hemostatic agents racestyptine, Dryz, and Expasyl™—and 80 specimens from each impression material—polyvinylsiloxane (PVS), polyether, and polyvinylsiloxane ether (PVSE), were fabricated and subjected to each astringent. The surface detail reproduction was examined using a stereomicroscope at 4x magnification, and the dimensional stability was analyzed at 24 hr with a measuring microscope. The surface detail data were statistically analyzed with Fisher’s test at a significance level of 0.05. The dimensional stability data were analyzed using two-way ANOVA and Tukey’s test at a significance level of 0.05. Aluminum chloride hemostatic agents can affect the surface detail reproduction of impression materials differently ( ). Thus, the first null hypothesis was rejected. PVS showed the highest percentage of satisfactory surface detail regardless of the hemostatic agent used in this study. PVSE showed a reduced percentage of satisfactory surface detail when the concentration of aluminum chloride was high. The three hemostatic agents affected the dimensional stability of each material differently ( ). Therefore, the second null hypothesis was also rejected.