Effect of Gingival Hemostatic Agents on the Surface Detail Reproduction and Dimension Stability of Three Elastomeric Impression Materials
Open Access
- 29 July 2023
- journal article
- research article
- Published by Wiley in International Journal of Dentistry
- Vol. 2023, 1-7
Abstract
This study aimed to evaluate the effects of aluminum chloride based hemostatic agents on the surface detail reproduction and dimension stability. Three impression materials were investigated after contaminated with three commercial astringents with different concentration of aluminum chloride. The specimens from three impression materials were fabricated with a stainless-steel mold that followed the American Dental Association specification no.19. The mold was preliminarily contaminated with three hemostatic agents racestyptine, Dryz, and Expasyl™—and 80 specimens from each impression material—polyvinylsiloxane (PVS), polyether, and polyvinylsiloxane ether (PVSE), were fabricated and subjected to each astringent. The surface detail reproduction was examined using a stereomicroscope at 4x magnification, and the dimensional stability was analyzed at 24 hr with a measuring microscope. The surface detail data were statistically analyzed with Fisher’s test at a significance level of 0.05. The dimensional stability data were analyzed using two-way ANOVA and Tukey’s test at a significance level of 0.05. Aluminum chloride hemostatic agents can affect the surface detail reproduction of impression materials differently ( ). Thus, the first null hypothesis was rejected. PVS showed the highest percentage of satisfactory surface detail regardless of the hemostatic agent used in this study. PVSE showed a reduced percentage of satisfactory surface detail when the concentration of aluminum chloride was high. The three hemostatic agents affected the dimensional stability of each material differently ( ). Therefore, the second null hypothesis was also rejected.Keywords
Funding Information
- Srinakharinwirot University (281/2564)
This publication has 18 references indexed in Scilit:
- Topical Hemostatic Agents2013
- Effects of sulfur-based hemostatic agents and gingival retraction cords handled with latex gloves on the polymerization of polyvinyl siloxane impression materialsJournal of Applied Oral Science, 2011
- Accuracy of the newly formulated vinyl siloxanether elastomeric impression materialThe Journal of Prosthetic Dentistry, 2010
- Effect of conventional and experimental gingival retraction solutions on the tensile strength and inhibition of polymerization of four types of impression materialsJournal of Applied Oral Science, 2008
- Moisture Effect on Polyether and Polyvinylsiloxane Dimensional Accuracy and Detail ReproductionJournal of Prosthodontics, 2005
- A review of contemporary impression materials and techniquesDental Clinics of North America, 2004
- Disturbance of the dentinal smear layer by acidic hemostatic agentsThe Journal of Prosthetic Dentistry, 1994
- Inhibition of polymerization of polyvinyl siloxanes by medicaments used on gingival retraction cordsThe Journal of Prosthetic Dentistry, 1993
- Review and survey of medicaments used with gingival retraction cordsThe Journal of Prosthetic Dentistry, 1985
- Silicones1982