Rentian Zhang
Research Subjects
Rentian Zhang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Honggeng Zhu
Yangzhou University
2 shared publications - Bin Xi
Yangzhou University, Yangzhou, Jiangsu, China
1 shared publication - Dapeng Hu
State Key Laboratory of Fine Chemicals, Frontier Science Center for Smart Materials, School of Chemical Engineering, Dalian University of Technology, Dalian 116024, China
1 shared publication - Fan Yang
College of Hydraulic Science and Engineering Yangzhou University, Yangzhou, 225009, China
1 shared publication - Fangping Tang
College of Hydraulic Science and Engineering, Yangzhou University 3 , Yangzhou 225009
1 shared publication Ge Bo
Jiangsu Surveying and Design Institution of Water Resources Co. Ltd
1 shared publication
Latest Publications
- Open Access
- 7 August 2018
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2018, 1-9
Pump Selection and Performance Prediction for the Technical Innovation of an Axial-Flow Pump Station
Axial-flow pumps are widely used in every sector of China. After many years of operation, the aging of mechanical and electrical facilities poses threats to their steady and safe operation. Taking the technical innovation of an axial-flow pump station as an example, the study is focused on the pump selection and performance prediction. The pump similarity law and specific speed were applied to guide the pump selection based on the designed head and discharge. The performances of pump models were compared and it is suggested for the technical innovation that when the selected model pump is adopted, the impeller diameter is kept at 3100 mm and the rotational speed is reduced from 150r/min to 136.4r/min to improve its cavitation performance. A three-dimensional pumping system model was established by using software Pro/E and CFD analyses were conducted to predict the hydraulic performance of the pumping system for the evaluation of technical innovation. It is shown through the comparison of computed results with model test results that the designed flow rate corresponding to the designed head can be fully satisfied with the selected pump and stronger pumping capacity can be prospected at the designed and mean lifting head. The pumping system model tests, in comparison between the original and the selected model pump, indicate that when the innovated pump station operates under characteristic heads, the pumping system efficiency can be raised by more than 3 percentages, and the cavitation allowance can be decreased by 0.90m; thus, better engineering and economic benefits can be prospected through the technical innovation.
- 7 August 2018
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2018, 1-9
Open AccessPump Selection and Performance Prediction for the Technical Innovation of an Axial-Flow Pump Station
Axial-flow pumps are widely used in every sector of China. After many years of operation, the aging of mechanical and electrical facilities poses threats to their steady and safe operation. Taking the technical innovation of an axial-flow pump station as an example, the study is focused on the pump selection and performance prediction. The pump similarity law and specific speed were applied to guide the pump selection based on the designed head and discharge. The performances of pump models were compared and it is suggested for the technical innovation that when the selected model pump is adopted, the impeller diameter is kept at 3100 mm and the rotational speed is reduced from 150r/min to 136.4r/min to improve its cavitation performance. A three-dimensional pumping system model was established by using software Pro/E and CFD analyses were conducted to predict the hydraulic performance of the pumping system for the evaluation of technical innovation. It is shown through the comparison of computed results with model test results that the designed flow rate corresponding to the designed head can be fully satisfied with the selected pump and stronger pumping capacity can be prospected at the designed and mean lifting head. The pumping system model tests, in comparison between the original and the selected model pump, indicate that when the innovated pump station operates under characteristic heads, the pumping system efficiency can be raised by more than 3 percentages, and the cavitation allowance can be decreased by 0.90m; thus, better engineering and economic benefits can be prospected through the technical innovation.
- Open Access
- 17 April 2018
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 10 (4)
Numerical calculation of axial-flow pump’s pressure fluctuation and model test analysis
To study the significance of internal pressure pulsation characteristics between prototype and model pump devices, monitoring of computational fluid dynamics and dynamic measurement of a model were carried out under different working conditions and measuring points. The results of computational fluid dynamics calculation and model test are as follows. First, the positions of main frequency and subfrequency are almost the same, whereas the amplitude has a slight deviation. Second, the amplitude of inlet impeller is larger, and the main frequency is three times of rotating frequency. Third, the inlet speaker has mainly low pulsation, which is almost distributed in blade frequency and 1/3 times of rotating frequency. Moreover, the pressure pulsation of symmetrical points in each condition has a good symmetry. As the flow rate decreases, both the mixing and blade frequency amplitudes in the inlet speaker and impeller first decrease and then increase. The minimum mixing amplitude appears in the design condition of 253 L/s, whereas the blade frequencies are 203 and 253 L/s. The numerical calculation results are almost the same as those of prototype and model devices. Therefore, numerical calculations and experimental studies on pressure pulsation can guide the design and stable operation of similar pump stations.
- 17 April 2018
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 10 (4)
Open AccessNumerical calculation of axial-flow pump’s pressure fluctuation and model test analysis
To study the significance of internal pressure pulsation characteristics between prototype and model pump devices, monitoring of computational fluid dynamics and dynamic measurement of a model were carried out under different working conditions and measuring points. The results of computational fluid dynamics calculation and model test are as follows. First, the positions of main frequency and subfrequency are almost the same, whereas the amplitude has a slight deviation. Second, the amplitude of inlet impeller is larger, and the main frequency is three times of rotating frequency. Third, the inlet speaker has mainly low pulsation, which is almost distributed in blade frequency and 1/3 times of rotating frequency. Moreover, the pressure pulsation of symmetrical points in each condition has a good symmetry. As the flow rate decreases, both the mixing and blade frequency amplitudes in the inlet speaker and impeller first decrease and then increase. The minimum mixing amplitude appears in the design condition of 253 L/s, whereas the blade frequencies are 203 and 253 L/s. The numerical calculation results are almost the same as those of prototype and model devices. Therefore, numerical calculations and experimental studies on pressure pulsation can guide the design and stable operation of similar pump stations.
- 7 July 2013
- Published by ASME International
Internal Flow Mechanism of Axial-Flow Pump With Adjustable Guide Vanes
Axial-flow pumps are widely used in many fields where low pumping head and large flow rate are required such as irrigation and drainage, flood control, bio-environmental protection and inter-basin water diversion. Conventional axial-flow pump diffuser is designed with post fixed guide vanes to eliminate circulation, diffuse water and decrease flow velocity while converting dynamic energy to pressure energy. Under designed flow rate the inlet setting angle of the fixed guide vanes is designed to be equal to the outlet flow angle of the impeller blades which is regarded to be the best operating condition. Under off-design conditions the outlet flow angle of the impeller blades does not match the inlet setting angle of guide vanes any more. As a result hydraulic losses are increased, flow separation appeared and vortex generated inside the diffuser, the operation conditions of pump is deteriorated, bringing in bad cavitation characteristics, more energy consumption and lower pumping efficiency. The proposal of Axial-flow pumps with adjustable guide vanes are put forward in this paper, in which the inlet setting angle of guide vanes can be adjusted to coordinate with the change of flow rate and impeller blade setting angle and guarantee the outlet flow angle of impeller blades matching the inlet setting angle of guide vanes. The three-dimensional time-averaged N-S equations, closed by the standard κ–ε turbulence model, are adopted to simulate the internal flow fields of axial-flow pumps with fixed and adjustable guide vanes, and their performances are predicted. The internal flow mechanism of an axial-flow pump with adjustable guide vanes is investigated, and computational fluid dynamics is adopted to simulate and analyze the internal flow fields. Computation results indicate that the value of the highest pumping efficiency is slight changed while the vane setting angle is adjusted when the inlet setting angles of blades are fixed and the setting angles of guide vanes are regulated. Under off-design conditions the flow conditions inside the diffuser of axial-flow pump with adjustable guide vanes can be improved, the hydraulic loss reduced and the pumping efficiency can be raised effectively.
- 7 July 2013
- Published by ASME International
Internal Flow Mechanism of Axial-Flow Pump With Adjustable Guide Vanes
Axial-flow pumps are widely used in many fields where low pumping head and large flow rate are required such as irrigation and drainage, flood control, bio-environmental protection and inter-basin water diversion. Conventional axial-flow pump diffuser is designed with post fixed guide vanes to eliminate circulation, diffuse water and decrease flow velocity while converting dynamic energy to pressure energy. Under designed flow rate the inlet setting angle of the fixed guide vanes is designed to be equal to the outlet flow angle of the impeller blades which is regarded to be the best operating condition. Under off-design conditions the outlet flow angle of the impeller blades does not match the inlet setting angle of guide vanes any more. As a result hydraulic losses are increased, flow separation appeared and vortex generated inside the diffuser, the operation conditions of pump is deteriorated, bringing in bad cavitation characteristics, more energy consumption and lower pumping efficiency. The proposal of Axial-flow pumps with adjustable guide vanes are put forward in this paper, in which the inlet setting angle of guide vanes can be adjusted to coordinate with the change of flow rate and impeller blade setting angle and guarantee the outlet flow angle of impeller blades matching the inlet setting angle of guide vanes. The three-dimensional time-averaged N-S equations, closed by the standard κ–ε turbulence model, are adopted to simulate the internal flow fields of axial-flow pumps with fixed and adjustable guide vanes, and their performances are predicted. The internal flow mechanism of an axial-flow pump with adjustable guide vanes is investigated, and computational fluid dynamics is adopted to simulate and analyze the internal flow fields. Computation results indicate that the value of the highest pumping efficiency is slight changed while the vane setting angle is adjusted when the inlet setting angles of blades are fixed and the setting angles of guide vanes are regulated. Under off-design conditions the flow conditions inside the diffuser of axial-flow pump with adjustable guide vanes can be improved, the hydraulic loss reduced and the pumping efficiency can be raised effectively.