Brian Albers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Brian Albers has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Aravinda Ganapathy
School of Medicine, Washington University in St. Louis, St. Louis, MO 63110, USA
3 shared publications - David Hilton Ballard
Mallinckrodt Institute of Radiology, Washington University School of Medicine in St. Louis, St. Louis, MO, USA
3 shared publications - Anup Shashindra Shetty
From the Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, Campus Box 8131, St Louis, MO 63110
2 shared publications - Anusha Elumalai
D Printing Lab, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA
2 shared publications - David Chen
D Printing Lab, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA
2 shared publications - Yuktesh Kalidindi
School of Medicine, Saint Louis University, St. Louis, MO 63104, USA
2 shared publications
Latest Publications
- Open Access
- 31 July 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (8) , 992
Customization of Computed Tomography Radio-Opacity in 3D-Printed Contrast-Injectable Tumor Phantoms
Medical Imaging Phantoms (MIPs) calibrate imaging devices, train medical professionals, and can help procedural planning. Traditional MIPs are costly and limited in customization. Additive manufacturing allows for customizable, patient-specific phantoms. This study examines the CT attenuation characteristics of contrast-injectable, chambered 3D-printed phantoms to optimize tissue-mimicking capabilities. A MIP was constructed from a CT of a complex pelvic tumor near the iliac bifurcation. A 3D reconstruction of these structures composed of three chambers (aorta, inferior vena cava, tumor) with ports for contrast injection was 3D printed. Desired attenuations were 200 HU (arterial I), 150 HU (venous I), 40 HU (tumor I), 150 HU (arterial II), 90 HU (venous II), and 400 HU (tumor II). Solutions of Optiray 350 and water were injected, and the phantom was scanned on CT. Attenuations were measured using ROIs. Mean attenuation for the six phases was as follows: 37.49 HU for tumor I, 200.50 HU for venous I, 227.92 HU for arterial I, 326.20 HU for tumor II, 91.32 HU for venous II, and 132.08 HU for arterial II. Although the percent differences between observed and goal attenuation were high, the observed relative HU differences between phases were similar to goal HU differences. The observed attenuations reflected the relative concentrations of contrast solutions used, exhibiting a strong positive correlation with contrast concentration. The contrast-injectable tumor phantom exhibited a useful physiologic range of attenuation values, enabling the modification of tissue-mimicking 3D-printed phantoms even after the manufacturing process.
- 31 July 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (8) , 992
Open AccessCustomization of Computed Tomography Radio-Opacity in 3D-Printed Contrast-Injectable Tumor Phantoms
Medical Imaging Phantoms (MIPs) calibrate imaging devices, train medical professionals, and can help procedural planning. Traditional MIPs are costly and limited in customization. Additive manufacturing allows for customizable, patient-specific phantoms. This study examines the CT attenuation characteristics of contrast-injectable, chambered 3D-printed phantoms to optimize tissue-mimicking capabilities. A MIP was constructed from a CT of a complex pelvic tumor near the iliac bifurcation. A 3D reconstruction of these structures composed of three chambers (aorta, inferior vena cava, tumor) with ports for contrast injection was 3D printed. Desired attenuations were 200 HU (arterial I), 150 HU (venous I), 40 HU (tumor I), 150 HU (arterial II), 90 HU (venous II), and 400 HU (tumor II). Solutions of Optiray 350 and water were injected, and the phantom was scanned on CT. Attenuations were measured using ROIs. Mean attenuation for the six phases was as follows: 37.49 HU for tumor I, 200.50 HU for venous I, 227.92 HU for arterial I, 326.20 HU for tumor II, 91.32 HU for venous II, and 132.08 HU for arterial II. Although the percent differences between observed and goal attenuation were high, the observed relative HU differences between phases were similar to goal HU differences. The observed attenuations reflected the relative concentrations of contrast solutions used, exhibiting a strong positive correlation with contrast concentration. The contrast-injectable tumor phantom exhibited a useful physiologic range of attenuation values, enabling the modification of tissue-mimicking 3D-printed phantoms even after the manufacturing process.
- Open Access
- 14 October 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (10) , 1928
Computed Tomography Attenuation of Three-Dimensional (3D) Printing Materials—Depository to Aid in Constructing 3D-Printed Phantoms
Three-dimensionally printed phantoms are increasingly used in medical imaging and research due to their cost-effectiveness and customizability, offering valuable alternatives to commercial phantoms. The purpose of this study was to assess the computed tomography (CT) attenuation characteristics of 27 resin materials from Formlabs, a 3D printing equipment and materials manufacturer. Cube phantoms (both solid and hollow constructions) produced with each resin were subjected to CT scanning under varying tube current–time products with attenuation measurements recorded in Hounsfield units (HU). The resins exhibited a wide range of attenuation values (−3.33 to 2666.27 HU), closely mimicking a range of human tissues, from fluids to dense bone structures. The resins also demonstrated consistent attenuation regardless of changes in the tube current. The CT attenuation analysis of FormLabs resins produced an archive of radiological imaging characteristics of photopolymers that can be utilized to construct more accurate tissue mimicking medical phantoms and improve the evaluation of imaging device performance.
- 14 October 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (10) , 1928
Open AccessComputed Tomography Attenuation of Three-Dimensional (3D) Printing Materials—Depository to Aid in Constructing 3D-Printed Phantoms
Three-dimensionally printed phantoms are increasingly used in medical imaging and research due to their cost-effectiveness and customizability, offering valuable alternatives to commercial phantoms. The purpose of this study was to assess the computed tomography (CT) attenuation characteristics of 27 resin materials from Formlabs, a 3D printing equipment and materials manufacturer. Cube phantoms (both solid and hollow constructions) produced with each resin were subjected to CT scanning under varying tube current–time products with attenuation measurements recorded in Hounsfield units (HU). The resins exhibited a wide range of attenuation values (−3.33 to 2666.27 HU), closely mimicking a range of human tissues, from fluids to dense bone structures. The resins also demonstrated consistent attenuation regardless of changes in the tube current. The CT attenuation analysis of FormLabs resins produced an archive of radiological imaging characteristics of photopolymers that can be utilized to construct more accurate tissue mimicking medical phantoms and improve the evaluation of imaging device performance.