AGAravinda Ganapathy

Aravinda Ganapathy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Aravinda Ganapathy has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Bedside Small-Bowel Challenge vs. Fluoroscopic Series for SBO: A Cost Effectiveness Analysis

    by Aravinda Krishna Ganapathy, Liam Cunningham, M. Hunter Lanier, Selasi Nakhaima, Madelyn Thiel, Daniel Hoffman, Obeid Ilahi, David H. Ballard, Vincent M. Mellnick

    Background: Small bowel obstruction (SBO) accounts for 12–16% of surgical hospital admissions and can lead to complications such as bowel ischemia. Traditional management requires transporting patients to the Radiology Department (RD) for a fluoroscopic small bowel series, occupying resources and time. This study evaluates the efficacy and efficiency of the Small Bowel Challenge Exam, a bedside alternative. Methods: A retrospective analysis was performed on 85 SBO patients from January 2018 to December 2023 at an academic tertiary care facility, comparing the traditional fluoroscopic series (37 patients) to the bedside Small Bowel Challenge Exam (48 patients). Key metrics analyzed included hospital resource utilization, overall costs, and length of stay. Results: Gender and race distributions were similar between groups (p = 0.268 and p = 0.808, respectively). Median total costs were lower in the challenge group (USD 1243 vs. USD 1472; p = 0.1229), significantly so when excluding CT scan costs (USD 993.5 vs. USD 1270; p = 0.0500). Core costs also significantly favored the challenge group (USD 389.6 vs. USD 615; p < 0.0001). Length of stay and variable costs showed no significant differences (p = 0.3846 and p = 0.8065, respectively). Additional imaging frequencies were comparable (p = 0.96 for CT scans; p = 0.97 for XR exams). Conclusions: The Small Bowel Challenge Exam reduces certain costs and logistical burdens without prolonging length of stay, suggesting more efficient use of hospital resources. Further research is recommended to evaluate broader implementation and long-term impacts.

  • Open Access

    Customization of Computed Tomography Radio-Opacity in 3D-Printed Contrast-Injectable Tumor Phantoms

    by Yuktesh Kalidindi, Aravinda Krishna Ganapathy, Liam Cunningham, Adriene Lovato, Brian Albers, Anup S. Shetty, David H. Ballard

    Medical Imaging Phantoms (MIPs) calibrate imaging devices, train medical professionals, and can help procedural planning. Traditional MIPs are costly and limited in customization. Additive manufacturing allows for customizable, patient-specific phantoms. This study examines the CT attenuation characteristics of contrast-injectable, chambered 3D-printed phantoms to optimize tissue-mimicking capabilities. A MIP was constructed from a CT of a complex pelvic tumor near the iliac bifurcation. A 3D reconstruction of these structures composed of three chambers (aorta, inferior vena cava, tumor) with ports for contrast injection was 3D printed. Desired attenuations were 200 HU (arterial I), 150 HU (venous I), 40 HU (tumor I), 150 HU (arterial II), 90 HU (venous II), and 400 HU (tumor II). Solutions of Optiray 350 and water were injected, and the phantom was scanned on CT. Attenuations were measured using ROIs. Mean attenuation for the six phases was as follows: 37.49 HU for tumor I, 200.50 HU for venous I, 227.92 HU for arterial I, 326.20 HU for tumor II, 91.32 HU for venous II, and 132.08 HU for arterial II. Although the percent differences between observed and goal attenuation were high, the observed relative HU differences between phases were similar to goal HU differences. The observed attenuations reflected the relative concentrations of contrast solutions used, exhibiting a strong positive correlation with contrast concentration. The contrast-injectable tumor phantom exhibited a useful physiologic range of attenuation values, enabling the modification of tissue-mimicking 3D-printed phantoms even after the manufacturing process.


  • Open Access

    Quantification of Visceral Fat at the L5 Vertebral Body Level in Patients with Crohn’s Disease Using T2-Weighted MRI

    by Favour Garuba, Aravinda Ganapathy, Spencer McKinley, Karan H. Jani, Adriene Lovato, Satish E. Viswanath, Scott McHenry, Parakkal Deepak, David H. Ballard

    The umbilical or L3 vertebral body level is often used for body fat quantification using computed tomography. To explore the feasibility of using clinically acquired pelvic magnetic resonance imaging (MRI) for visceral fat measurement, we examined the correlation of visceral fat parameters at the umbilical and L5 vertebral body levels. We retrospectively analyzed T2-weighted half-Fourier acquisition single-shot turbo spin echo (HASTE) MR axial images from Crohn’s disease patients who underwent MRI enterography of the abdomen and pelvis over a three-year period. We determined the area/volume of subcutaneous and visceral fat from the umbilical and L5 levels and calculated the visceral fat ratio (VFR = visceral fat/subcutaneous fat) and visceral fat index (VFI = visceral fat/total fat). Statistical analyses involved correlation analysis between both levels, inter-rater analysis between two investigators, and inter-platform analysis between two image-analysis platforms. Correlational analysis of 32 patients yielded significant associations for VFI (r = 0.85; p < 0.0001) and VFR (r = 0.74; p < 0.0001). Intraclass coefficients for VFI and VFR were 0.846 and 0.875 (good agreement) between investigators and 0.831 and 0.728 (good and moderate agreement) between platforms. Our study suggests that the L5 level on clinically acquired pelvic MRIs may serve as a reference point for visceral fat quantification.


  • Open Access

    Reverse Engineering and 3D Printing of Medical Devices for Drug Delivery and Drug-Embedded Anatomic Implants

    by Anusha Elumalai, Yash Nayak, Aravinda K. Ganapathy, David Chen, Karthik Tappa, Udayabhanu Jammalamadaka, Grace Bishop, David H. Ballard

    In recent years, 3D printing (3DP) has advanced traditional medical treatments. This review explores the fusion of reverse engineering and 3D printing of medical implants, with a specific focus on drug delivery applications. The potential for 3D printing technology to create patient-specific implants and intricate anatomical models is discussed, along with its ability to address challenges in medical treatment. The article summarizes the current landscape, challenges, benefits, and emerging trends of using 3D-printed formulations for medical implantation and drug delivery purposes.


  • Open Access

    Computed Tomography Attenuation of Three-Dimensional (3D) Printing Materials—Depository to Aid in Constructing 3D-Printed Phantoms

    by Yuktesh Kalidindi, Aravinda Krishna Ganapathy, Yash Nayak, Anusha Elumalai, David Z. Chen, Grace Bishop, Adrian Sanchez, Brian Albers, Anup S. Shetty, David H. Ballard

    Three-dimensionally printed phantoms are increasingly used in medical imaging and research due to their cost-effectiveness and customizability, offering valuable alternatives to commercial phantoms. The purpose of this study was to assess the computed tomography (CT) attenuation characteristics of 27 resin materials from Formlabs, a 3D printing equipment and materials manufacturer. Cube phantoms (both solid and hollow constructions) produced with each resin were subjected to CT scanning under varying tube current–time products with attenuation measurements recorded in Hounsfield units (HU). The resins exhibited a wide range of attenuation values (−3.33 to 2666.27 HU), closely mimicking a range of human tissues, from fluids to dense bone structures. The resins also demonstrated consistent attenuation regardless of changes in the tube current. The CT attenuation analysis of FormLabs resins produced an archive of radiological imaging characteristics of photopolymers that can be utilized to construct more accurate tissue mimicking medical phantoms and improve the evaluation of imaging device performance.


  • Open Access

    Global variations in treatment and outcomes reported for anterior shoulder instability: a systematic review of the literature

    by Derrick M. Knapik, Andrew W. Kuhn, Aravinda Ganapathy, Joseph T. Gibian, Lauren H. Yaeger, Matthew J. Matava, Matthew V. Smith, Robert H. Brophy


  • Open Access

    Analysis of Superficial Subcutaneous Fat Camper’s and Scarpa’s Fascia in a United States Cohort

    by David Z. Chen, Aravinda Ganapathy, Yash Nayak, Christopher Mejias, Grace L. Bishop, Vincent M. Mellnick, David H. Ballard

    Together, the Camper’s and Scarpa’s fasciae form the superficial fat layer of the abdominal wall. Though they have clinical and surgical relevance, little is known about their role in body composition across diverse patient populations. This study aimed to determine the relationship between patient characteristics, including sex and body mass index, and the distribution of Camper’s and Scarpa’s fascial layers in the abdominal wall. A total of 458 patients’ abdominal CT examinations were segmented via CoreSlicer 1.0 to determine the surface area of each patient’s Camper’s, Scarpa’s, and visceral fascia layers. The reproducibility of segmentation was corroborated by an inter-rater analysis of segmented data for 20 randomly chosen patients divided between three study investigators. Pearson correlation and Student’s t-test analyses were performed to characterize the relationship between fascia distribution and demographic factors. The ratios of Camper’s fascia, both as a proportion of superficial fat (r = −0.44 and p < 0.0001) and as a proportion of total body fat (r = −0.34 and p < 0.0001), showed statistically significant negative correlations with BMI. In contrast, the ratios of Scarpa’s fascia, both as a proportion of superficial fat (r = 0.44 and p < 0.0001) and as a proportion of total body fat (r = 0.41 and p < 0.0001), exhibited statistically significant positive correlations with BMI. Between sexes, the females had a higher ratio of Scarpa’s facia to total body fat compared to the males (36.9% vs. 31% and p < 0.0001). The ICC values for the visceral fat, Scarpa fascia, and Camper fascia were 0.995, 0.991, and 0.995, respectively, which were all within the ‘almost perfect’ range (ICC = 0.81–1.00). These findings contribute novel insights by revealing that as BMI increases the proportion of Camper’s fascia decreases, while the ratio of Scarpa’s fascia increases. Such insights expand the scope of body composition studies, which typically focus solely on superficial and visceral fat ratios.


  • Open Access

    Orthopaedic Surgery Training and Education During COVID-19

    by Zachary D. Randall, Aravinda Ganapathy, Andrew W. Kuhn, Richard M. Silverman, Paul M. Inclan, Alexander W. Aleem

    Background: COVID-19 forced surgical resident training programs to adapt to meet educational requirements within the constraints of various guidelines. Some of the changes implemented during the pandemic have imparted a lasting effect on orthopaedic education. As such, the purpose of this article was to review how orthopaedic training and education were affected during the COVID-19 pandemic. Methods: The published literature was queried using search strategies devised by a medical librarian, according to the Preferred Reporting Items for Systematic Review and Meta-Analyses guidelines. Studies eligible for inclusion were studies related to COVID-19, orthopaedic surgical training, and medical education. Studies were excluded if they (1) were abstracts, conference proceedings, letters, perspective pieces, reviews, or editorials; (2) evaluated medical student education; (3) included other specialties; or (4) were unrelated to COVID-19 and/or orthopaedic training. Results: Eighty-three (n = 83) studies were included. Five themes emerged including (I) Fellowship Application, Interview, and Match Processes; (II) Social Media and Websites for Program Information; (III) Changes in Trainee Surgical Volume; (IV) Trainee Mental Health and Well-being; and (V) Innovations in Education. The pandemic decreased opportunities for medical students to gain exposure to orthopaedic surgery. Social media use, particularly Instagram, among orthopaedic residencies increased during the pandemic. Between the cancellation of away rotations and in-person interviews, applicants saved over $6,000; however, both residency applicants and interviewers preferred in-person interviews. The pandemic led to decreased surgical volume and in-person didactics for trainees, thus relying more on virtual learning. Orthopaedic trainees had mixed feelings regarding online virtual education. Although some respondents reported that they preferred the convenience of online learning, others expressed dissatisfaction with the quality of virtual education. Conclusions: The shift to virtual learning affected how applicants learned about residency programs, with many relying on virtual away rotations and social media to compare different programs. The pandemic also highlighted issues of diversity and accessibility within orthopaedic surgery, with cost savings from virtual interviews and canceled away rotations potentially benefiting applicants from lower socioeconomic backgrounds. Although some innovative approaches and adaptations to orthopaedic education and training have shown promise and may continue to be used in the future after the COVID-19 pandemic, the role of others, such as virtual interviews, is less clear.


  • Open Access

    Pilot Study on the Influence of Incentive Spirometry on Percutaneous Image-Guided Intra-Abdominal Drainage Catheter Pressure: A Potential Method to Enhance Drainage

    by Aravinda Ganapathy, David H. Ballard, Grace L. Bishop, Mark J. Hoegger, Nihil Abraham, Horacio B. D’agostino

    Background: To report the evaluation of incentive spirometry (IS)-induced pressure changes in intra-abdominal drainage catheters and consider its use for maintaining catheter patency and enhancing drainage. Methods: Prospective study of patients with indwelling intra-abdominal drainage catheters for abdominal fluid collections who had their intra-abdominal pressures measured while performing incentive spirometry. Patients were instructed in the use of an incentive spirometer. Within a week after initial drainage, pressure changes with IS were evaluated three times at 1500 cc and three times at maximum inspiratory effort. Intra-abdominal pressure (IAP) was measured using a pressure monitor connected to the drainage catheter. Results: Twenty patients (men, 12; women, 8). Fluid collection locations were pelvis, Right-upper quadrant (RUQ), Left-upper quadrant (LUQ), Left-lower quadrant (LLQ), and Right-lower quadrant (RLQ). A total of 16 of 20 patients showed an elevation of IAP with IS. At 1500 cc, the pressure increased by an average of 41.24 mmH2O. At maximal inspiratory effort, the pressure increased by an average of 48.26 mmH2O. Pressure increase was greater in upper abdomen catheters. Four patients with lower abdominal and pelvic collections showed minimal pressure changes with IS. Conclusion: IS increases IAP and fluid flow through abdominal drainage catheters. Future studies are warranted to determine whether the use of IS enhances catheter performance and facilitates drainage via its effect on IAP.


  • Guide for starting or optimizing a 3D printing clinical service

    by Aravinda Ganapathy, David Chen, Anusha Elumalai, Brian Albers, Karthik Tappa, Udayabhanu Jammalamadaka, Mark J. Hoegger, David H. Ballard