Meng Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Meng Zhou has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Jinyu Wen
Huazhong University of Science and Technology
4 shared publications - Wang Xiang
State Key Laboratory of Advanced Electromagnetic Technology, Huazhong University of Science and Technology, Wuhan, China
4 shared publications - Weixing Lin
TBEA SunOasis Co,. Ltd, Urumuchi 830011, Xinjiang, China
3 shared publications - Wenping Zuo
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
3 shared publications - Binye Ni
School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, 12443 Wuhan, Hubei China 430074
1 shared publication - Ganghua Zhang
School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
1 shared publication
Latest Publications
- 10 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2441-2453
DC Impedance Modeling of Push-Pull DC Auto-Transformer for MMC and LCC HVDC Interconnections
The push-pull DC autotransformer (PPDAT) is a potential power equipment to interconnect the MMC and LCC HVDC systems. However, the harmonic stability of the PPDAT remains an unsolved challenge. In this paper, considering the dual closed-loop control and bidirectional DC voltage operation of the PPDAT, its DC impedance models are proposed using the harmonic transfer function (HTF) method. Both the DC impedance models at the high/low voltage side considering the harmonic coupling and internal dynamics of the hybrid MMC/LCC HVDC system are deduced. The accuracy of the detailed DC impedance models is validated in PSCAD/EMTDC simulations. The impedance analysis under bidirectional DC voltage operation scenarios reveals that the DC voltage polarity affects the low frequency region. Besides, the main impact of PPDAT's parameters on the wideband impedance characteristics is disclosed. It shows that unreasonable parameter design will bring negative damping characteristics near the resonance point (RP). Moreover, stability analysis considering the interaction of PPDAT and LCC-HVDC at the high-voltage side is conducted. The results indicate that the potential resonances can be readily predicted through the Nyquist diagrams and the negative damping of the PPDAT may cause instability at RP.
- 10 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2441-2453
DC Impedance Modeling of Push-Pull DC Auto-Transformer for MMC and LCC HVDC Interconnections
The push-pull DC autotransformer (PPDAT) is a potential power equipment to interconnect the MMC and LCC HVDC systems. However, the harmonic stability of the PPDAT remains an unsolved challenge. In this paper, considering the dual closed-loop control and bidirectional DC voltage operation of the PPDAT, its DC impedance models are proposed using the harmonic transfer function (HTF) method. Both the DC impedance models at the high/low voltage side considering the harmonic coupling and internal dynamics of the hybrid MMC/LCC HVDC system are deduced. The accuracy of the detailed DC impedance models is validated in PSCAD/EMTDC simulations. The impedance analysis under bidirectional DC voltage operation scenarios reveals that the DC voltage polarity affects the low frequency region. Besides, the main impact of PPDAT's parameters on the wideband impedance characteristics is disclosed. It shows that unreasonable parameter design will bring negative damping characteristics near the resonance point (RP). Moreover, stability analysis considering the interaction of PPDAT and LCC-HVDC at the high-voltage side is conducted. The results indicate that the potential resonances can be readily predicted through the Nyquist diagrams and the negative damping of the PPDAT may cause instability at RP.
- Open Access
- 3 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (5) , 5631-5645
A Differential Pilot Protection Scheme for MMC-Based DC Grid Resilient to Communication Failure
Primary single-end line protection strategies of MMC HVDC systems are difficult to make a tradeoff between fast detection speed and high reliability. To improve reliability, the pilot protection schemes based on communication and data exchange can be adopted. However, the communication-based schemes suffer from potential communication failure problems, such as data error, data loss and time synchronization error. To avoid blocking of protection devices during communication failures, a resilience-oriented differential pilot protection method is proposed in this paper. To address the problem of synchronization error, a startup element based on the multi-resolution morphological gradient (MMG) of traveling wave is proposed. For the problems of data error and data loss in communication, the sampled data are preprocessed by the morphological filtering (MF). And the correlation of traveling waves is used to identify the internal and external faults; the ratio of the morphological gradient of pole voltages is adopted to discriminate the faulty poles. A four-terminal MMC based DC grid model is built in PSCAD/EMTDC interfaced with the optical fiber-based communication system built in MATLAB/Simulink. The simulation results show that the protection scheme can effectively identify the faults against serious communication problems of 1% bit error rate and 5% data loss.
- 3 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (5) , 5631-5645
Open AccessA Differential Pilot Protection Scheme for MMC-Based DC Grid Resilient to Communication Failure
Primary single-end line protection strategies of MMC HVDC systems are difficult to make a tradeoff between fast detection speed and high reliability. To improve reliability, the pilot protection schemes based on communication and data exchange can be adopted. However, the communication-based schemes suffer from potential communication failure problems, such as data error, data loss and time synchronization error. To avoid blocking of protection devices during communication failures, a resilience-oriented differential pilot protection method is proposed in this paper. To address the problem of synchronization error, a startup element based on the multi-resolution morphological gradient (MMG) of traveling wave is proposed. For the problems of data error and data loss in communication, the sampled data are preprocessed by the morphological filtering (MF). And the correlation of traveling waves is used to identify the internal and external faults; the ratio of the morphological gradient of pole voltages is adopted to discriminate the faulty poles. A four-terminal MMC based DC grid model is built in PSCAD/EMTDC interfaced with the optical fiber-based communication system built in MATLAB/Simulink. The simulation results show that the protection scheme can effectively identify the faults against serious communication problems of 1% bit error rate and 5% data loss.
- 25 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 920-931
An Adaptive Fault Current Limiting Control for MMC and Its Application in DC Grid
This paper proposes an adaptive fault current limiting control (AFCLC) for modular multilevel converters (MMC). Without introducing extra current limiting devices, this control scheme enables fast fault current suppression during DC faults. The AFCLC will be triggered automatically once DC faults occur. By adaptively reducing the output DC voltages of MMCs, the fault current can be suppressed. Compared with the existing current limiting methods, the proposed AFCLC has a better performance on fault current limiting, since it only depends on the real-time operating condition and no fault detection delay is imposed. Firstly, the principle of the proposed AFCLC together with the mathematical analysis is disclosed. Then, the sensitivity analysis of the impact of key control parameters on the current limiting effect is investigated. Finally, the effectiveness of AFCLC is demonstrated in a four-terminal HVDC grid test model. The simulation results show that the proposed AFCLC can reduce the interrupted current and energy absorption of a DCCB from 10.39 kA and 38.24 MJ to 4.62 kA and 8.32 MJ, respectively. The simulation results also prove that the AFCLC will not affect the accuracy of the DC fault detection algorithms under DC faults.
- 25 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 920-931
An Adaptive Fault Current Limiting Control for MMC and Its Application in DC Grid
This paper proposes an adaptive fault current limiting control (AFCLC) for modular multilevel converters (MMC). Without introducing extra current limiting devices, this control scheme enables fast fault current suppression during DC faults. The AFCLC will be triggered automatically once DC faults occur. By adaptively reducing the output DC voltages of MMCs, the fault current can be suppressed. Compared with the existing current limiting methods, the proposed AFCLC has a better performance on fault current limiting, since it only depends on the real-time operating condition and no fault detection delay is imposed. Firstly, the principle of the proposed AFCLC together with the mathematical analysis is disclosed. Then, the sensitivity analysis of the impact of key control parameters on the current limiting effect is investigated. Finally, the effectiveness of AFCLC is demonstrated in a four-terminal HVDC grid test model. The simulation results show that the proposed AFCLC can reduce the interrupted current and energy absorption of a DCCB from 10.39 kA and 38.24 MJ to 4.62 kA and 8.32 MJ, respectively. The simulation results also prove that the AFCLC will not affect the accuracy of the DC fault detection algorithms under DC faults.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 30, 1339-1342
Research on the Single Current Regulator Flux-Weakening Control for Permanent Magnet Linear Synchronous Motor
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 30, 1339-1342
Research on the Single Current Regulator Flux-Weakening Control for Permanent Magnet Linear Synchronous Motor
- Open Access
A Unidirectional DC-DC Autotransformer for DC Grid Application
Conventional unidirectional DC-DC converters for DC grid application employ DC-AC-DC two-stage conversion technology and suffer from high converter cost and power loss. To solve these issues, a unidirectional step-up DC-DC autotransformer (UUDAT) and a unidirectional step-down DC-DC autotransformer (DUDAT) are studied. The UUDAT and DUDAT are composed of a series connection of diode bridges and voltage source converters. Topologies of UUDAT and DUDAT are detailed. The harmonic and un-controllability issues are discussed. Control and possible application scenarios for UUDAT and DUDAT are depicted. DC fault isolation mechanism and the methods of dimensioning the voltage and power ratings of the components in UUDAT and DUDAT are studied. Extensive simulations on power system level and experiments on a UUDAT and DUDAT prototype verified their technical feasibility.
Open AccessA Unidirectional DC-DC Autotransformer for DC Grid Application
Conventional unidirectional DC-DC converters for DC grid application employ DC-AC-DC two-stage conversion technology and suffer from high converter cost and power loss. To solve these issues, a unidirectional step-up DC-DC autotransformer (UUDAT) and a unidirectional step-down DC-DC autotransformer (DUDAT) are studied. The UUDAT and DUDAT are composed of a series connection of diode bridges and voltage source converters. Topologies of UUDAT and DUDAT are detailed. The harmonic and un-controllability issues are discussed. Control and possible application scenarios for UUDAT and DUDAT are depicted. DC fault isolation mechanism and the methods of dimensioning the voltage and power ratings of the components in UUDAT and DUDAT are studied. Extensive simulations on power system level and experiments on a UUDAT and DUDAT prototype verified their technical feasibility.