Samuel Pereira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Samuel Pereira has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- André Carvalho
University of Victoria
1 shared publication - Diogo Montalvão
Bournemouth University
1 shared publication - Luis Reis
University of Lisbon Lisbon Portugal
1 shared publication - Manuel de Freitas
Atlântica – Instituto Universitário Barcarena Portugal
1 shared publication
Latest Publications
- Open Access
- 27 June 2019
- Published by Gruppo Italiano Frattura in Fracture and Structural Integrity
- Vol. 13 (49) , 450-462
Characterisation and Evaluation of the Mechanical Behaviour of Endodontic-grade NiTi Wires
With the introduction of new materials and advances in medical science, the endodontic files have changed since the early days of root canal treatments. In the late days, we have seen an increasing use of Nickel-Titanium (NiTi) alloys, to the detriment of more conventional alloys. At body temperature, NiTi alloys present a superelastic behaviour, which allows to be more effective in the removal of the tooth pulp tissue, and in the protection of the tooth structure. Anyhow, these NiTi instruments will eventually fracture, usually without any visual signal of degradation. Thus, there is a need of studying these alloys, as they present a high hysteresis cycle and non-linearities in the Elastic domain. Currently, there is no international standard to test NiTi endodontic files, so various authors have attempted to design systems that can test them under fatigue loads, usually based on empirical setups. Following a systematic approach, this work presents the results of rotary fatigue tests for two Alfa Aesar® Nitinol wires with different diameters (0.58mm and 0.25mm).The formulation is presented, where the material strength reduction can be quantified from the determination of the strain and the number of cycles until failure, as well numerical FEM simulation to verify the analytical model predictions.
- 27 June 2019
- Published by Gruppo Italiano Frattura in Fracture and Structural Integrity
- Vol. 13 (49) , 450-462
Open AccessCharacterisation and Evaluation of the Mechanical Behaviour of Endodontic-grade NiTi Wires
With the introduction of new materials and advances in medical science, the endodontic files have changed since the early days of root canal treatments. In the late days, we have seen an increasing use of Nickel-Titanium (NiTi) alloys, to the detriment of more conventional alloys. At body temperature, NiTi alloys present a superelastic behaviour, which allows to be more effective in the removal of the tooth pulp tissue, and in the protection of the tooth structure. Anyhow, these NiTi instruments will eventually fracture, usually without any visual signal of degradation. Thus, there is a need of studying these alloys, as they present a high hysteresis cycle and non-linearities in the Elastic domain. Currently, there is no international standard to test NiTi endodontic files, so various authors have attempted to design systems that can test them under fatigue loads, usually based on empirical setups. Following a systematic approach, this work presents the results of rotary fatigue tests for two Alfa Aesar® Nitinol wires with different diameters (0.58mm and 0.25mm).The formulation is presented, where the material strength reduction can be quantified from the determination of the strain and the number of cycles until failure, as well numerical FEM simulation to verify the analytical model predictions.