Barak Sabbagh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Barak Sabbagh has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Gilad Yossifon
Tel Aviv University
5 shared publications - Joseph Wang
University of California San Diego
4 shared publications - Muhammad Inam Khan
University of California San Diego
3 shared publications - Omeed Djassemi
University of California San Diego
3 shared publications - Tamoghna Saha
Aiiso Yufeng Li Family Department of Chemical and NanoEngineering, University of California San Diego, La Jolla, USA
3 shared publications - Abdulhameed Abdal
Department of Mechanical Engineering, University of California San Diego, La Jolla, USA
2 shared publications
Latest Publications
- Open Access
- 11 November 2026
- Published by Springer Nature in Research Square
Continuous glucose monitoring earbuds for periodic metabolic sensing
The applications of continuous glucose monitoring (CGM) are expanding into wellness, sports and preventive health, where metabolic information is particularly valuable around specific physiological events. However, conventional CGMs remain tailored to diabetes management, requiring around-the-clock, fixed wear even when periodic monitoring is sufficient. Here, we introduce the continuous glucose in-ear monitor (cGEM), an earbud-integrated platform for periodic, on-demand glucose monitoring from in-ear sweat. The cGEM establishes a skin–sensor interface through simple insertion and removal, enabling repeated monitoring without adhesive fixation. The platform integrates osmotic sweat extraction, microfluidic sampling and electrochemical glucose sensing while retaining audio playback. Computational modelling and in vitro characterization demonstrated controlled fluid transport and reliable glucose sensing. Dual-channel adaptive noise cancellation and personalized calibration reduce on-body signal artifacts and account for individual differences in blood–sweat glucose relationships. Despite periodic use, the cGEM showed close agreement with a continuously worn commercial CGM, achieving a mean absolute relative difference (MARD) of 8.79% across more than 50 h of monitoring. Repeated 1.5–5 h sessions captured event-specific glucose responses with a Pearson correlation coefficient of r = 0.88 relative to the commercial CGM. By integrating molecular sensing into widely used wireless earbuds, cGEM opens new possibilities for widespread adoption of metabolic monitoring, making it as accessible and routine as listening to music.
- 11 November 2026
- Published by Springer Nature in Research Square
Open AccessContinuous glucose monitoring earbuds for periodic metabolic sensing
The applications of continuous glucose monitoring (CGM) are expanding into wellness, sports and preventive health, where metabolic information is particularly valuable around specific physiological events. However, conventional CGMs remain tailored to diabetes management, requiring around-the-clock, fixed wear even when periodic monitoring is sufficient. Here, we introduce the continuous glucose in-ear monitor (cGEM), an earbud-integrated platform for periodic, on-demand glucose monitoring from in-ear sweat. The cGEM establishes a skin–sensor interface through simple insertion and removal, enabling repeated monitoring without adhesive fixation. The platform integrates osmotic sweat extraction, microfluidic sampling and electrochemical glucose sensing while retaining audio playback. Computational modelling and in vitro characterization demonstrated controlled fluid transport and reliable glucose sensing. Dual-channel adaptive noise cancellation and personalized calibration reduce on-body signal artifacts and account for individual differences in blood–sweat glucose relationships. Despite periodic use, the cGEM showed close agreement with a continuously worn commercial CGM, achieving a mean absolute relative difference (MARD) of 8.79% across more than 50 h of monitoring. Repeated 1.5–5 h sessions captured event-specific glucose responses with a Pearson correlation coefficient of r = 0.88 relative to the commercial CGM. By integrating molecular sensing into widely used wireless earbuds, cGEM opens new possibilities for widespread adoption of metabolic monitoring, making it as accessible and routine as listening to music.
- Open Access
- 23 July 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 9003
A fully integrated smart ring for daily biochemical monitoring
Biochemical analysis complements biophysical measurements by capturing the underlying molecular and metabolic changes that drive physiological health. Here, we introduce a compact, fully integrated smart ring capable of simultaneously monitoring multiple chemical biomarkers in real-time — marking a true biochemical counterpart to existing smart rings. Our ring can continuously measure glucose, ketone, ascorbic acid, uric acid, lactate, and alcohol from passive osmotically extracted sweat, is powered by custom-built high-capacity flexible Zn-AgO batteries, and comprises ultra-compact, energy-efficient electronics for data processing and wireless transmission. It can support ~12 hours of continuous monitoring and preserves personalized calibration stability for ~2 months. The simultaneous biomarker monitoring was validated under diverse daily settings. Reliable, continuous monitoring of glucose and ketone levels showed strong agreement with commercial blood meters and continuous glucose monitors in both healthy and type 1 diabetic individuals, confirming the ring’s accuracy even for at-risk population. Overall, our ring extends beyond commercial smart rings focusing on only biophysical signals, by enabling continuous assessment of biochemical changes and advancing the development of next generation personalized and miniaturized healthcare technologies.
- 23 July 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 9003
Open AccessA fully integrated smart ring for daily biochemical monitoring
Biochemical analysis complements biophysical measurements by capturing the underlying molecular and metabolic changes that drive physiological health. Here, we introduce a compact, fully integrated smart ring capable of simultaneously monitoring multiple chemical biomarkers in real-time — marking a true biochemical counterpart to existing smart rings. Our ring can continuously measure glucose, ketone, ascorbic acid, uric acid, lactate, and alcohol from passive osmotically extracted sweat, is powered by custom-built high-capacity flexible Zn-AgO batteries, and comprises ultra-compact, energy-efficient electronics for data processing and wireless transmission. It can support ~12 hours of continuous monitoring and preserves personalized calibration stability for ~2 months. The simultaneous biomarker monitoring was validated under diverse daily settings. Reliable, continuous monitoring of glucose and ketone levels showed strong agreement with commercial blood meters and continuous glucose monitors in both healthy and type 1 diabetic individuals, confirming the ring’s accuracy even for at-risk population. Overall, our ring extends beyond commercial smart rings focusing on only biophysical signals, by enabling continuous assessment of biochemical changes and advancing the development of next generation personalized and miniaturized healthcare technologies.
- 7 April 2026
- Published by American Chemical Society (ACS) in ACS Sensors
Self-Correction of pH-Induced Signal Variations in Methylene Blue-Labeled Aptamer Electrochemical Biosensors: Wearable Cortisol Detection in Sweat
Common electrochemical aptamer-based (E-AB) biosensors employing methylene blue (MB) redox reporters suffer from significant pH-induced signal variations. Consequently, dynamic pH fluctuations in biofluids, such as in sweat, can greatly distort the measured signal and lead to inaccurate target quantification. Here, we introduce a self-correction strategy that enables accurate analyte quantification by compensating for pH-induced signal variations in MB-based aptasensors using the Nernstian shift of the MB peak potential. The highly reproducible reversible pH dependence of the MB peak potential enables real-time monitoring of the sample pH that provides a continuously synchronized built-in compensation of the pH interference, thereby eliminating the need for external pH sensors or additional measurement steps. This precise yet simple and effective self-correction of pH effects ensures that the Square Wave Voltammetry (SWV) signal reliably reflects real-time analyte variations, as demonstrated using a cortisol MB-labeled E-AB biosensor in both in vitro and on-body settings. In vitro measurements in artificial sweat across pH 5.5-7.5 showed excellent correlation with real-time pH and cortisol changes, confirming the reliability of the peak potential-based correction. On-body measurements using an epidermal wearable patch showed cortisol changes in sweat that would have been missed without this signal-correction method. This approach is broadly applicable to other MB-labeled E-AB biosensors and biofluids, providing a robust strategy for continuous on-body monitoring.
- 7 April 2026
- Published by American Chemical Society (ACS) in ACS Sensors
Self-Correction of pH-Induced Signal Variations in Methylene Blue-Labeled Aptamer Electrochemical Biosensors: Wearable Cortisol Detection in Sweat
Common electrochemical aptamer-based (E-AB) biosensors employing methylene blue (MB) redox reporters suffer from significant pH-induced signal variations. Consequently, dynamic pH fluctuations in biofluids, such as in sweat, can greatly distort the measured signal and lead to inaccurate target quantification. Here, we introduce a self-correction strategy that enables accurate analyte quantification by compensating for pH-induced signal variations in MB-based aptasensors using the Nernstian shift of the MB peak potential. The highly reproducible reversible pH dependence of the MB peak potential enables real-time monitoring of the sample pH that provides a continuously synchronized built-in compensation of the pH interference, thereby eliminating the need for external pH sensors or additional measurement steps. This precise yet simple and effective self-correction of pH effects ensures that the Square Wave Voltammetry (SWV) signal reliably reflects real-time analyte variations, as demonstrated using a cortisol MB-labeled E-AB biosensor in both in vitro and on-body settings. In vitro measurements in artificial sweat across pH 5.5-7.5 showed excellent correlation with real-time pH and cortisol changes, confirming the reliability of the peak potential-based correction. On-body measurements using an epidermal wearable patch showed cortisol changes in sweat that would have been missed without this signal-correction method. This approach is broadly applicable to other MB-labeled E-AB biosensors and biofluids, providing a robust strategy for continuous on-body monitoring.
- Open Access
- 25 February 2026
- Published by Springer Nature in Research Square
A Fully Integrated Smart Ring for Daily Biochemical Monitoring
Biochemical analysis complements biophysical measurements by capturing the underlying molecular and metabolic changes that drive physiological health. Here, we introduce a compact, fully integrated smart ring capable of simultaneously monitoring multiple chemical biomarkers in real-time — marking a true biochemical counterpart to existing smart rings. Our ring can continuously measure glucose, ketone, ascorbic acid, uric acid, lactate, and alcohol from passive osmotically extracted sweat, is powered by custom-built high-capacity flexible Zn-AgO batteries, and comprises ultra-compact, energy-efficient electronics for data processing and wireless transmission. It can support ~12 hours of continuous monitoring and preserves personalized calibration stability for ~2 months. The simultaneous biomarker monitoring was validated under diverse daily settings. Reliable, continuous monitoring of glucose and ketone levels showed strong agreement with commercial blood meters and continuous glucose monitors in both healthy and type 1 diabetic individuals, confirming the ring’s accuracy even for at-risk population. Overall, our ring extends beyond commercial smart rings focusing on only biophysical signals, by enabling continuous assessment of biochemical changes and advancing the development of next generation personalized and miniaturized healthcare technologies.
- 25 February 2026
- Published by Springer Nature in Research Square
Open AccessA Fully Integrated Smart Ring for Daily Biochemical Monitoring
Biochemical analysis complements biophysical measurements by capturing the underlying molecular and metabolic changes that drive physiological health. Here, we introduce a compact, fully integrated smart ring capable of simultaneously monitoring multiple chemical biomarkers in real-time — marking a true biochemical counterpart to existing smart rings. Our ring can continuously measure glucose, ketone, ascorbic acid, uric acid, lactate, and alcohol from passive osmotically extracted sweat, is powered by custom-built high-capacity flexible Zn-AgO batteries, and comprises ultra-compact, energy-efficient electronics for data processing and wireless transmission. It can support ~12 hours of continuous monitoring and preserves personalized calibration stability for ~2 months. The simultaneous biomarker monitoring was validated under diverse daily settings. Reliable, continuous monitoring of glucose and ketone levels showed strong agreement with commercial blood meters and continuous glucose monitors in both healthy and type 1 diabetic individuals, confirming the ring’s accuracy even for at-risk population. Overall, our ring extends beyond commercial smart rings focusing on only biophysical signals, by enabling continuous assessment of biochemical changes and advancing the development of next generation personalized and miniaturized healthcare technologies.
- Open Access
- 22 October 2025
- Published by Springer Nature in Communications Engineering
- Vol. 4 (1) , 1-12
Toward an ion-based large-scale integrated circuit: design, simulation, and integration
Iontronics combines ions as information carriers with electronic-like operations, enabling the creation of ion-based integrated circuits that offer unique signal processing, chemical regulation, and enhanced bio-integrability. Existing simulation tools encounter difficulties in effectively modeling integrated iontronic components, highlighting the need for specialized design and simulation methodologies. Here we present a design approach toward ion-based large-scale integrated circuits, inspired by electronic integrated circuit abstraction levels. We develop a compact model for the iontronic bipolar diode, with a conceptual framework applicable to other iontronic components. The model is implemented using standard Electronic Design Automation tools, allowing simulation of static and dynamic properties of iontronic circuits. Simulated results match measurements from fabricated small-scale iontronic circuits. The proposed simulation approach employs Monte Carlo methodology and enables exploration of how component non-uniformity influences circuit behavior. We demonstrate the model’s utility by simulating ion-based integrated circuits, including an iontronic decoder and diode bridge. Expanding traditional circuit design tools to support iontronics could advance the development of hybrid systems that leverage both electronic and ionic functionalities.
- 22 October 2025
- Published by Springer Nature in Communications Engineering
- Vol. 4 (1) , 1-12
Open AccessToward an ion-based large-scale integrated circuit: design, simulation, and integration
Iontronics combines ions as information carriers with electronic-like operations, enabling the creation of ion-based integrated circuits that offer unique signal processing, chemical regulation, and enhanced bio-integrability. Existing simulation tools encounter difficulties in effectively modeling integrated iontronic components, highlighting the need for specialized design and simulation methodologies. Here we present a design approach toward ion-based large-scale integrated circuits, inspired by electronic integrated circuit abstraction levels. We develop a compact model for the iontronic bipolar diode, with a conceptual framework applicable to other iontronic components. The model is implemented using standard Electronic Design Automation tools, allowing simulation of static and dynamic properties of iontronic circuits. Simulated results match measurements from fabricated small-scale iontronic circuits. The proposed simulation approach employs Monte Carlo methodology and enables exploration of how component non-uniformity influences circuit behavior. We demonstrate the model’s utility by simulating ion-based integrated circuits, including an iontronic decoder and diode bridge. Expanding traditional circuit design tools to support iontronics could advance the development of hybrid systems that leverage both electronic and ionic functionalities.
- Open Access
- 9 September 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (18) , 4765-4775
Enhancing commercially available immunoassays through a customized electrokinetic biomolecular preconcentration device
Ion concentration polarization (ICP) based molecular preconcentration.
- 9 September 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (18) , 4765-4775
Open AccessEnhancing commercially available immunoassays through a customized electrokinetic biomolecular preconcentration device
Ion concentration polarization (ICP) based molecular preconcentration.
- Open Access
- 1 April 2025
- Published by Springer Nature in Research Square
Toward an Ion-Based Large-Scale Integrated Circuit: Circuit Level Design, Simulation, and Integration of Iontronic Components
Iontronics combines ions as charge carriers with electronic-like operations, enabling unique information processing, chemical regulation, and enhanced bio-integrability. This paper presents a design approach for iontronic integrated circuits, inspired by electronic abstraction layer methodology. As a fundamental step, we develop a compact model to the iontronic bipolar diode, with a conceptual framework applicable to other iontronic components. The model, grounded in the diode’s physical properties and observed behavior, is implemented using standard VLSI (Very Large-Scale Integration) electronic design tools. Our simulations demonstrate diode-based circuit behaviors, highlighting how component parameters affect circuit interactions and performance. To improve accuracy, we integrate Monte Carlo techniques, addressing circuit variations. Expanding simulation tools to include iontronic components offers insights into circuit design potential, with tested applications in energy harvesting and logic circuits. By improving component uniformity, optimizing diode parameters, and understanding diode characteristics, we can achieve more complex and efficient iontronic systems, moving closer to practical and groundbreaking applications in the field.
- 1 April 2025
- Published by Springer Nature in Research Square
Open AccessToward an Ion-Based Large-Scale Integrated Circuit: Circuit Level Design, Simulation, and Integration of Iontronic Components
Iontronics combines ions as charge carriers with electronic-like operations, enabling unique information processing, chemical regulation, and enhanced bio-integrability. This paper presents a design approach for iontronic integrated circuits, inspired by electronic abstraction layer methodology. As a fundamental step, we develop a compact model to the iontronic bipolar diode, with a conceptual framework applicable to other iontronic components. The model, grounded in the diode’s physical properties and observed behavior, is implemented using standard VLSI (Very Large-Scale Integration) electronic design tools. Our simulations demonstrate diode-based circuit behaviors, highlighting how component parameters affect circuit interactions and performance. To improve accuracy, we integrate Monte Carlo techniques, addressing circuit variations. Expanding simulation tools to include iontronic components offers insights into circuit design potential, with tested applications in energy harvesting and logic circuits. By improving component uniformity, optimizing diode parameters, and understanding diode characteristics, we can achieve more complex and efficient iontronic systems, moving closer to practical and groundbreaking applications in the field.
- Open Access
- 28 May 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (23) , 15025-15034
Geometrically Scalable Iontronic Memristors: Employing Bipolar Polyelectrolyte Gels for Neuromorphic Systems
Iontronics that are capable of mimicking the functionality of biological systems within an artificial fluidic network have long been pursued for biomedical applications and ion-based intelligence systems. Here, we report on facile and robust realization of iontronic bipolar memristors featuring a three-layer polyelectrolyte gel structure. Significant memristive hysteresis of ion currents was successfully accomplished, and the memory time proved geometrically scalable from 200 to 4000 s. These characteristics were enabled by the ion concentration polarization-induced rectification ratio within the polyelectrolyte gels. The memristors exhibited memory dynamics akin to those observed in unipolar devices, while the bipolar structure notably enabled prolonged memory time and enhanced the ion conductance switching ratio with mesoscale (10-1000 μm) geometry precision. These properties endow the devices with the capability of effective neuromorphic processing with pulse-based input voltage signals. Owing to their simple fabrication process and superior memristive performance, the presented iontronic bipolar memristors are versatile and can be easily integrated into small-scale iontronic circuits, thereby facilitating advanced neuromorphic computing functionalities.
- 28 May 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (23) , 15025-15034
Open AccessGeometrically Scalable Iontronic Memristors: Employing Bipolar Polyelectrolyte Gels for Neuromorphic Systems
Iontronics that are capable of mimicking the functionality of biological systems within an artificial fluidic network have long been pursued for biomedical applications and ion-based intelligence systems. Here, we report on facile and robust realization of iontronic bipolar memristors featuring a three-layer polyelectrolyte gel structure. Significant memristive hysteresis of ion currents was successfully accomplished, and the memory time proved geometrically scalable from 200 to 4000 s. These characteristics were enabled by the ion concentration polarization-induced rectification ratio within the polyelectrolyte gels. The memristors exhibited memory dynamics akin to those observed in unipolar devices, while the bipolar structure notably enabled prolonged memory time and enhanced the ion conductance switching ratio with mesoscale (10-1000 μm) geometry precision. These properties endow the devices with the capability of effective neuromorphic processing with pulse-based input voltage signals. Owing to their simple fabrication process and superior memristive performance, the presented iontronic bipolar memristors are versatile and can be easily integrated into small-scale iontronic circuits, thereby facilitating advanced neuromorphic computing functionalities.
- Open Access
- 2 August 2023
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 246, 141-156
Logic gating of low-abundance molecules using polyelectrolyte-based diodes
Bioinspired artificial ionic components are extensively utilized to mimic biological systems, as the vast majority of biological signaling is mediated by ions and molecules. Particular attention is given to nanoscale fluidic components where the ion transport can be regulated by the induced ion permselectivity. As a step from fundamentals toward ion-controlled devices, this study presents the use of ionic diodes made of oppositely charged polyelectrolytes, as a gate for low-abundance molecules. The use of ionic diodes that exhibited nonlinear current–voltage responses enabled realization of a basic Boolean operation of an ionic OR logic gate. Aside from the electrical response, the asymmetric ion transport through the diode was shown to affect the transport of low-abundance molecules across the diode, only allowing crossing when the diode was forward-biased. Integration of multiple diodes enabled implementation of an OR logic operation on both the voltage and the molecule transport, while obtaining electrical and optical output readouts that were associated with low and high logic levels. Similarly to electronics, implementation of logic gates opens up new functionalities of on-chip ionic computation via integrated circuits consisting of multiple basic logic gates.
- 2 August 2023
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 246, 141-156
Open AccessLogic gating of low-abundance molecules using polyelectrolyte-based diodes
Bioinspired artificial ionic components are extensively utilized to mimic biological systems, as the vast majority of biological signaling is mediated by ions and molecules. Particular attention is given to nanoscale fluidic components where the ion transport can be regulated by the induced ion permselectivity. As a step from fundamentals toward ion-controlled devices, this study presents the use of ionic diodes made of oppositely charged polyelectrolytes, as a gate for low-abundance molecules. The use of ionic diodes that exhibited nonlinear current–voltage responses enabled realization of a basic Boolean operation of an ionic OR logic gate. Aside from the electrical response, the asymmetric ion transport through the diode was shown to affect the transport of low-abundance molecules across the diode, only allowing crossing when the diode was forward-biased. Integration of multiple diodes enabled implementation of an OR logic operation on both the voltage and the molecule transport, while obtaining electrical and optical output readouts that were associated with low and high logic levels. Similarly to electronics, implementation of logic gates opens up new functionalities of on-chip ionic computation via integrated circuits consisting of multiple basic logic gates.