BSBarak Sabbagh

Barak Sabbagh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Barak Sabbagh has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Continuous glucose monitoring earbuds for periodic metabolic sensing

    by Joseph Wang, Barak Sabbagh, Christian Gosti, Ellen V Stadler, Madeleine McSwain, Lauren Chiu, Muhammad Inam Khan, Qinyu Yu, Victor Perez, Tamoghna Saha, et al.

    The applications of continuous glucose monitoring (CGM) are expanding into wellness, sports and preventive health, where metabolic information is particularly valuable around specific physiological events. However, conventional CGMs remain tailored to diabetes management, requiring around-the-clock, fixed wear even when periodic monitoring is sufficient. Here, we introduce the continuous glucose in-ear monitor (cGEM), an earbud-integrated platform for periodic, on-demand glucose monitoring from in-ear sweat. The cGEM establishes a skin–sensor interface through simple insertion and removal, enabling repeated monitoring without adhesive fixation. The platform integrates osmotic sweat extraction, microfluidic sampling and electrochemical glucose sensing while retaining audio playback. Computational modelling and in vitro characterization demonstrated controlled fluid transport and reliable glucose sensing. Dual-channel adaptive noise cancellation and personalized calibration reduce on-body signal artifacts and account for individual differences in blood–sweat glucose relationships. Despite periodic use, the cGEM showed close agreement with a continuously worn commercial CGM, achieving a mean absolute relative difference (MARD) of 8.79% across more than 50 h of monitoring. Repeated 1.5–5 h sessions captured event-specific glucose responses with a Pearson correlation coefficient of r = 0.88 relative to the commercial CGM. By integrating molecular sensing into widely used wireless earbuds, cGEM opens new possibilities for widespread adoption of metabolic monitoring, making it as accessible and routine as listening to music.

  • Open Access

    A fully integrated smart ring for daily biochemical monitoring

    by Tamoghna Saha, Shichao Ding, Siyu Qin, Hannah Fishman, Rosie Pham, Te Gu, Muyang Lin, Yushan Xian, Barak Sabbagh, Abdulhameed Abdal, et al.

    Biochemical analysis complements biophysical measurements by capturing the underlying molecular and metabolic changes that drive physiological health. Here, we introduce a compact, fully integrated smart ring capable of simultaneously monitoring multiple chemical biomarkers in real-time — marking a true biochemical counterpart to existing smart rings. Our ring can continuously measure glucose, ketone, ascorbic acid, uric acid, lactate, and alcohol from passive osmotically extracted sweat, is powered by custom-built high-capacity flexible Zn-AgO batteries, and comprises ultra-compact, energy-efficient electronics for data processing and wireless transmission. It can support ~12 hours of continuous monitoring and preserves personalized calibration stability for ~2 months. The simultaneous biomarker monitoring was validated under diverse daily settings. Reliable, continuous monitoring of glucose and ketone levels showed strong agreement with commercial blood meters and continuous glucose monitors in both healthy and type 1 diabetic individuals, confirming the ring’s accuracy even for at-risk population. Overall, our ring extends beyond commercial smart rings focusing on only biophysical signals, by enabling continuous assessment of biochemical changes and advancing the development of next generation personalized and miniaturized healthcare technologies.


  • Self-Correction of pH-Induced Signal Variations in Methylene Blue-Labeled Aptamer Electrochemical Biosensors: Wearable Cortisol Detection in Sweat

    by Barak Sabbagh, Muhammad Inam Khan, Gyeongho Kim, Ponnusamy Nandhakumar, Lauren Chiu, Hao Zheng, Avani Jakasania, Victor Perez, Tamoghna Saha, Minjoon Park, et al.

    Common electrochemical aptamer-based (E-AB) biosensors employing methylene blue (MB) redox reporters suffer from significant pH-induced signal variations. Consequently, dynamic pH fluctuations in biofluids, such as in sweat, can greatly distort the measured signal and lead to inaccurate target quantification. Here, we introduce a self-correction strategy that enables accurate analyte quantification by compensating for pH-induced signal variations in MB-based aptasensors using the Nernstian shift of the MB peak potential. The highly reproducible reversible pH dependence of the MB peak potential enables real-time monitoring of the sample pH that provides a continuously synchronized built-in compensation of the pH interference, thereby eliminating the need for external pH sensors or additional measurement steps. This precise yet simple and effective self-correction of pH effects ensures that the Square Wave Voltammetry (SWV) signal reliably reflects real-time analyte variations, as demonstrated using a cortisol MB-labeled E-AB biosensor in both in vitro and on-body settings. In vitro measurements in artificial sweat across pH 5.5-7.5 showed excellent correlation with real-time pH and cortisol changes, confirming the reliability of the peak potential-based correction. On-body measurements using an epidermal wearable patch showed cortisol changes in sweat that would have been missed without this signal-correction method. This approach is broadly applicable to other MB-labeled E-AB biosensors and biofluids, providing a robust strategy for continuous on-body monitoring.


  • Open Access

    A Fully Integrated Smart Ring for Daily Biochemical Monitoring

    by Joseph Wang, Tamoghna Saha, Shichao Ding, Siyu Qin, Hannah Fishman, Rosie Pham, Te Gu, Muyang Lin, Yushan Xian, Barak Sabbagh, et al.

    Biochemical analysis complements biophysical measurements by capturing the underlying molecular and metabolic changes that drive physiological health. Here, we introduce a compact, fully integrated smart ring capable of simultaneously monitoring multiple chemical biomarkers in real-time — marking a true biochemical counterpart to existing smart rings. Our ring can continuously measure glucose, ketone, ascorbic acid, uric acid, lactate, and alcohol from passive osmotically extracted sweat, is powered by custom-built high-capacity flexible Zn-AgO batteries, and comprises ultra-compact, energy-efficient electronics for data processing and wireless transmission. It can support ~12 hours of continuous monitoring and preserves personalized calibration stability for ~2 months. The simultaneous biomarker monitoring was validated under diverse daily settings. Reliable, continuous monitoring of glucose and ketone levels showed strong agreement with commercial blood meters and continuous glucose monitors in both healthy and type 1 diabetic individuals, confirming the ring’s accuracy even for at-risk population. Overall, our ring extends beyond commercial smart rings focusing on only biophysical signals, by enabling continuous assessment of biochemical changes and advancing the development of next generation personalized and miniaturized healthcare technologies.

  • Open Access

    Toward an ion-based large-scale integrated circuit: design, simulation, and integration

    by Noa Edri Fraiman, Barak Sabbagh, Gilad Yossifon, Alexander Fish

    Iontronics combines ions as information carriers with electronic-like operations, enabling the creation of ion-based integrated circuits that offer unique signal processing, chemical regulation, and enhanced bio-integrability. Existing simulation tools encounter difficulties in effectively modeling integrated iontronic components, highlighting the need for specialized design and simulation methodologies. Here we present a design approach toward ion-based large-scale integrated circuits, inspired by electronic integrated circuit abstraction levels. We develop a compact model for the iontronic bipolar diode, with a conceptual framework applicable to other iontronic components. The model is implemented using standard Electronic Design Automation tools, allowing simulation of static and dynamic properties of iontronic circuits. Simulated results match measurements from fabricated small-scale iontronic circuits. The proposed simulation approach employs Monte Carlo methodology and enables exploration of how component non-uniformity influences circuit behavior. We demonstrate the model’s utility by simulating ion-based integrated circuits, including an iontronic decoder and diode bridge. Expanding traditional circuit design tools to support iontronics could advance the development of hybrid systems that leverage both electronic and ionic functionalities.


  • Open Access

    Enhancing commercially available immunoassays through a customized electrokinetic biomolecular preconcentration device

    by Barak Sabbagh, Sinwook Park, Gilad Yossifon

    Ion concentration polarization (ICP) based molecular preconcentration.


  • Open Access

    Toward an Ion-Based Large-Scale Integrated Circuit: Circuit Level Design, Simulation, and Integration of Iontronic Components

    by Noa Edri Fraiman, Barak Sabbagh, Gilad Yossifon, Alexander Fish

    Iontronics combines ions as charge carriers with electronic-like operations, enabling unique information processing, chemical regulation, and enhanced bio-integrability. This paper presents a design approach for iontronic integrated circuits, inspired by electronic abstraction layer methodology. As a fundamental step, we develop a compact model to the iontronic bipolar diode, with a conceptual framework applicable to other iontronic components. The model, grounded in the diode’s physical properties and observed behavior, is implemented using standard VLSI (Very Large-Scale Integration) electronic design tools. Our simulations demonstrate diode-based circuit behaviors, highlighting how component parameters affect circuit interactions and performance. To improve accuracy, we integrate Monte Carlo techniques, addressing circuit variations. Expanding simulation tools to include iontronic components offers insights into circuit design potential, with tested applications in energy harvesting and logic circuits. By improving component uniformity, optimizing diode parameters, and understanding diode characteristics, we can achieve more complex and efficient iontronic systems, moving closer to practical and groundbreaking applications in the field.


  • Open Access

    Geometrically Scalable Iontronic Memristors: Employing Bipolar Polyelectrolyte Gels for Neuromorphic Systems

    by Zhenyu Zhang, Barak Sabbagh, Yunfei Chen, Gilad Yossifon

    Iontronics that are capable of mimicking the functionality of biological systems within an artificial fluidic network have long been pursued for biomedical applications and ion-based intelligence systems. Here, we report on facile and robust realization of iontronic bipolar memristors featuring a three-layer polyelectrolyte gel structure. Significant memristive hysteresis of ion currents was successfully accomplished, and the memory time proved geometrically scalable from 200 to 4000 s. These characteristics were enabled by the ion concentration polarization-induced rectification ratio within the polyelectrolyte gels. The memristors exhibited memory dynamics akin to those observed in unipolar devices, while the bipolar structure notably enabled prolonged memory time and enhanced the ion conductance switching ratio with mesoscale (10-1000 μm) geometry precision. These properties endow the devices with the capability of effective neuromorphic processing with pulse-based input voltage signals. Owing to their simple fabrication process and superior memristive performance, the presented iontronic bipolar memristors are versatile and can be easily integrated into small-scale iontronic circuits, thereby facilitating advanced neuromorphic computing functionalities.


  • Open Access

    Logic gating of low-abundance molecules using polyelectrolyte-based diodes

    by Barak Sabbagh, Zhenyu Zhang, Gilad Yossifon

    Bioinspired artificial ionic components are extensively utilized to mimic biological systems, as the vast majority of biological signaling is mediated by ions and molecules. Particular attention is given to nanoscale fluidic components where the ion transport can be regulated by the induced ion permselectivity. As a step from fundamentals toward ion-controlled devices, this study presents the use of ionic diodes made of oppositely charged polyelectrolytes, as a gate for low-abundance molecules. The use of ionic diodes that exhibited nonlinear current–voltage responses enabled realization of a basic Boolean operation of an ionic OR logic gate. Aside from the electrical response, the asymmetric ion transport through the diode was shown to affect the transport of low-abundance molecules across the diode, only allowing crossing when the diode was forward-biased. Integration of multiple diodes enabled implementation of an OR logic operation on both the voltage and the molecule transport, while obtaining electrical and optical output readouts that were associated with low and high logic levels. Similarly to electronics, implementation of logic gates opens up new functionalities of on-chip ionic computation via integrated circuits consisting of multiple basic logic gates.