Muhammad Inam Khan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Muhammad Inam Khan has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Joseph Wang
University of California San Diego
5 shared publications - Omeed Djassemi
University of California San Diego
4 shared publications - Barak Sabbagh
University of California, San Diego
3 shared publications - Tamoghna Saha
Aiiso Yufeng Li Family Department of Chemical and NanoEngineering, University of California San Diego, La Jolla, USA
3 shared publications - Abdulhameed Abdal
Department of Mechanical Engineering, University of California San Diego, La Jolla, USA
2 shared publications Bumsik Choi
Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, 9500 Gilman Drive, La Jolla, 92093, CA, USA
2 shared publications
Latest Publications
- Open Access
- 11 November 2026
- Published by Springer Nature in Research Square
Continuous glucose monitoring earbuds for periodic metabolic sensing
The applications of continuous glucose monitoring (CGM) are expanding into wellness, sports and preventive health, where metabolic information is particularly valuable around specific physiological events. However, conventional CGMs remain tailored to diabetes management, requiring around-the-clock, fixed wear even when periodic monitoring is sufficient. Here, we introduce the continuous glucose in-ear monitor (cGEM), an earbud-integrated platform for periodic, on-demand glucose monitoring from in-ear sweat. The cGEM establishes a skin–sensor interface through simple insertion and removal, enabling repeated monitoring without adhesive fixation. The platform integrates osmotic sweat extraction, microfluidic sampling and electrochemical glucose sensing while retaining audio playback. Computational modelling and in vitro characterization demonstrated controlled fluid transport and reliable glucose sensing. Dual-channel adaptive noise cancellation and personalized calibration reduce on-body signal artifacts and account for individual differences in blood–sweat glucose relationships. Despite periodic use, the cGEM showed close agreement with a continuously worn commercial CGM, achieving a mean absolute relative difference (MARD) of 8.79% across more than 50 h of monitoring. Repeated 1.5–5 h sessions captured event-specific glucose responses with a Pearson correlation coefficient of r = 0.88 relative to the commercial CGM. By integrating molecular sensing into widely used wireless earbuds, cGEM opens new possibilities for widespread adoption of metabolic monitoring, making it as accessible and routine as listening to music.
- 11 November 2026
- Published by Springer Nature in Research Square
Open AccessContinuous glucose monitoring earbuds for periodic metabolic sensing
The applications of continuous glucose monitoring (CGM) are expanding into wellness, sports and preventive health, where metabolic information is particularly valuable around specific physiological events. However, conventional CGMs remain tailored to diabetes management, requiring around-the-clock, fixed wear even when periodic monitoring is sufficient. Here, we introduce the continuous glucose in-ear monitor (cGEM), an earbud-integrated platform for periodic, on-demand glucose monitoring from in-ear sweat. The cGEM establishes a skin–sensor interface through simple insertion and removal, enabling repeated monitoring without adhesive fixation. The platform integrates osmotic sweat extraction, microfluidic sampling and electrochemical glucose sensing while retaining audio playback. Computational modelling and in vitro characterization demonstrated controlled fluid transport and reliable glucose sensing. Dual-channel adaptive noise cancellation and personalized calibration reduce on-body signal artifacts and account for individual differences in blood–sweat glucose relationships. Despite periodic use, the cGEM showed close agreement with a continuously worn commercial CGM, achieving a mean absolute relative difference (MARD) of 8.79% across more than 50 h of monitoring. Repeated 1.5–5 h sessions captured event-specific glucose responses with a Pearson correlation coefficient of r = 0.88 relative to the commercial CGM. By integrating molecular sensing into widely used wireless earbuds, cGEM opens new possibilities for widespread adoption of metabolic monitoring, making it as accessible and routine as listening to music.
- Open Access
- 23 July 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 9003
A fully integrated smart ring for daily biochemical monitoring
Biochemical analysis complements biophysical measurements by capturing the underlying molecular and metabolic changes that drive physiological health. Here, we introduce a compact, fully integrated smart ring capable of simultaneously monitoring multiple chemical biomarkers in real-time — marking a true biochemical counterpart to existing smart rings. Our ring can continuously measure glucose, ketone, ascorbic acid, uric acid, lactate, and alcohol from passive osmotically extracted sweat, is powered by custom-built high-capacity flexible Zn-AgO batteries, and comprises ultra-compact, energy-efficient electronics for data processing and wireless transmission. It can support ~12 hours of continuous monitoring and preserves personalized calibration stability for ~2 months. The simultaneous biomarker monitoring was validated under diverse daily settings. Reliable, continuous monitoring of glucose and ketone levels showed strong agreement with commercial blood meters and continuous glucose monitors in both healthy and type 1 diabetic individuals, confirming the ring’s accuracy even for at-risk population. Overall, our ring extends beyond commercial smart rings focusing on only biophysical signals, by enabling continuous assessment of biochemical changes and advancing the development of next generation personalized and miniaturized healthcare technologies.
- 23 July 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 9003
Open AccessA fully integrated smart ring for daily biochemical monitoring
Biochemical analysis complements biophysical measurements by capturing the underlying molecular and metabolic changes that drive physiological health. Here, we introduce a compact, fully integrated smart ring capable of simultaneously monitoring multiple chemical biomarkers in real-time — marking a true biochemical counterpart to existing smart rings. Our ring can continuously measure glucose, ketone, ascorbic acid, uric acid, lactate, and alcohol from passive osmotically extracted sweat, is powered by custom-built high-capacity flexible Zn-AgO batteries, and comprises ultra-compact, energy-efficient electronics for data processing and wireless transmission. It can support ~12 hours of continuous monitoring and preserves personalized calibration stability for ~2 months. The simultaneous biomarker monitoring was validated under diverse daily settings. Reliable, continuous monitoring of glucose and ketone levels showed strong agreement with commercial blood meters and continuous glucose monitors in both healthy and type 1 diabetic individuals, confirming the ring’s accuracy even for at-risk population. Overall, our ring extends beyond commercial smart rings focusing on only biophysical signals, by enabling continuous assessment of biochemical changes and advancing the development of next generation personalized and miniaturized healthcare technologies.
- Open Access
- 25 February 2026
- Published by Springer Nature in Research Square
A Fully Integrated Smart Ring for Daily Biochemical Monitoring
Biochemical analysis complements biophysical measurements by capturing the underlying molecular and metabolic changes that drive physiological health. Here, we introduce a compact, fully integrated smart ring capable of simultaneously monitoring multiple chemical biomarkers in real-time — marking a true biochemical counterpart to existing smart rings. Our ring can continuously measure glucose, ketone, ascorbic acid, uric acid, lactate, and alcohol from passive osmotically extracted sweat, is powered by custom-built high-capacity flexible Zn-AgO batteries, and comprises ultra-compact, energy-efficient electronics for data processing and wireless transmission. It can support ~12 hours of continuous monitoring and preserves personalized calibration stability for ~2 months. The simultaneous biomarker monitoring was validated under diverse daily settings. Reliable, continuous monitoring of glucose and ketone levels showed strong agreement with commercial blood meters and continuous glucose monitors in both healthy and type 1 diabetic individuals, confirming the ring’s accuracy even for at-risk population. Overall, our ring extends beyond commercial smart rings focusing on only biophysical signals, by enabling continuous assessment of biochemical changes and advancing the development of next generation personalized and miniaturized healthcare technologies.
- 25 February 2026
- Published by Springer Nature in Research Square
Open AccessA Fully Integrated Smart Ring for Daily Biochemical Monitoring
Biochemical analysis complements biophysical measurements by capturing the underlying molecular and metabolic changes that drive physiological health. Here, we introduce a compact, fully integrated smart ring capable of simultaneously monitoring multiple chemical biomarkers in real-time — marking a true biochemical counterpart to existing smart rings. Our ring can continuously measure glucose, ketone, ascorbic acid, uric acid, lactate, and alcohol from passive osmotically extracted sweat, is powered by custom-built high-capacity flexible Zn-AgO batteries, and comprises ultra-compact, energy-efficient electronics for data processing and wireless transmission. It can support ~12 hours of continuous monitoring and preserves personalized calibration stability for ~2 months. The simultaneous biomarker monitoring was validated under diverse daily settings. Reliable, continuous monitoring of glucose and ketone levels showed strong agreement with commercial blood meters and continuous glucose monitors in both healthy and type 1 diabetic individuals, confirming the ring’s accuracy even for at-risk population. Overall, our ring extends beyond commercial smart rings focusing on only biophysical signals, by enabling continuous assessment of biochemical changes and advancing the development of next generation personalized and miniaturized healthcare technologies.
- 15 October 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 292, 118100
A smart cup for wireless, biofuel-powered, sweat-based vitamin C sensing
- 15 October 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 292, 118100
A smart cup for wireless, biofuel-powered, sweat-based vitamin C sensing