Samarjit Sengupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Samarjit Sengupta has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Debopoma Kar Ray
MCKV Institute of Engineering
1 shared publication - Surajit Chattopadhyay
Department of Electrical Engineering, Ghani Khan Choudhury Institute of Engineering and Technology, Malda, West Bengal, India
1 shared publication
Latest Publications
- 6 August 2018
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 66 (4) , 491-504
Multi-Resolution-Analysis-based Line-to-Ground Fault Detection in a VSC-Based HVDC System
This paper deals with the identification of single line-to-ground (LG) fault in a voltage source controller based high voltage direct current (HVDC) link, monitoring the multi-resolution-analysis (MRA)-based discrete wavelet transform (DWT) coefficients. A prototype model has been developed to assess the system at normal and at LG fault at the receiving end of the HVDC link, monitoring the AC sending end current in the system. This study also deals with the assessment of locations of LG faults in the HVDC link at different positions, from the sending end. Case studies have been carried out using field data and different DWT-based statistical parameters have been estimated and their variations due to fault have been observed. Then DWT-level-based optimization and parametric optimization have been done. An algorithm has been developed for fault assessment. Based on the specific outcome of the case studies, distance relaying scheme has been proposed, which has been validated with software simulation based on real field data.
- 6 August 2018
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 66 (4) , 491-504
Multi-Resolution-Analysis-based Line-to-Ground Fault Detection in a VSC-Based HVDC System
This paper deals with the identification of single line-to-ground (LG) fault in a voltage source controller based high voltage direct current (HVDC) link, monitoring the multi-resolution-analysis (MRA)-based discrete wavelet transform (DWT) coefficients. A prototype model has been developed to assess the system at normal and at LG fault at the receiving end of the HVDC link, monitoring the AC sending end current in the system. This study also deals with the assessment of locations of LG faults in the HVDC link at different positions, from the sending end. Case studies have been carried out using field data and different DWT-based statistical parameters have been estimated and their variations due to fault have been observed. Then DWT-level-based optimization and parametric optimization have been done. An algorithm has been developed for fault assessment. Based on the specific outcome of the case studies, distance relaying scheme has been proposed, which has been validated with software simulation based on real field data.