FJFuchang Jiang

Fuchang Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fuchang Jiang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cumulative Transfer Function for Assessment of MRI-Induced RF Heating Risk in Pediatric Patients Implanted with Bifurcated Leads

    by Fuchang Jiang, Jasmine Vu, Bhumi Bhusal, Yifeng Qian, Safa Hameed, Daniel Kim, Gregory Webster, Giorgio Bonmassar, Laleh Golestanirad

    Purpose: RF-induced heating remains a major barrier to MRI access for patients with epicardial cardiac implantable electronic devices (CIEDs). Although ISO/TS 10974 Tier-3 transfer function (TF) methods are established for unbranched leads, no analogous framework exists for bifurcated leads, in which branch asymmetry and inter-branch coupling may substantially alter heating. We developed and validated a cumulative transfer function (cTF) framework to address this gap. Methods: Following ISO/TS 10974 Tier-3 formalism, we measured, calibrated, and validated cTFs for a commercial 35 cm bipolar epicardial lead at 1.5 T. The framework explicitly accounts for branch-specific response and cross-branch coupling. Validation was performed with 24 canonical lead configurations in a homogeneous phantom and, without recalibration, in a heterogeneous anthropomorphic pediatric phantom with clinically derived trajectories. A single-branch TF approximation served as a comparator. The validated cTF was applied to predict RF heating across adult and pediatric human models at multiple imaging landmarks. Results: Compared with the single-branch TF approximation, the cTF reduced prediction error by nearly 70% in the primary validation dataset. In secondary validation, the cTF maintained low error across clinically relevant trajectories and imaging landmarks. In human models, the framework revealed marked anatomy- and landmark-dependent variation in predicted heating for the tested 35 cm lead, with low predicted heating in pediatric models and substantially higher heating in selected adult chest and upper abdominal imaging scenarios. Conclusion: The cTF provides a validated framework for RF-heating assessment of bifurcated leads and substantially improves prediction accuracy over single-branch TF approximations that neglect branch coupling.

  • Open Access

    Experimental Validation of Finite Element Models for Directional DBS: The Critical Role of Boundary Conditions on VTA Accuracy

    by Kaylee R. Henry, Fuchang Jiang, William A Wartman, Dexuan Tang, Yifeng Qian, Behzad Elahi, Sergey N. Makaroff, Laleh Golestani Rad

    Objective: Computational models and visualization toolboxes for Deep Brain Stimulation (DBS) increasingly rely on pre-computed electric field libraries to estimate the Volume of Tissue Activated (VTA). However, the boundary conditions (BCs) and source models used to generate these fields vary widely across studies, and there is currently no experimental consensus regarding which parameters most accurately reflect the physical device output. The objective of this study was to experimentally validate the electric potential distribution of directional DBS leads in order to determine the optimal Finite Element Method (FEM) configuration. Approach: The voltage distribution surrounding a Boston Scientific Vercise Gevia directional lead was mapped in a saline phantom using a custom high-precision robotic scanning system. Experimental measurements were compared against six FEM configurations that varied in source formulation (Dirichlet vs. Neumann boundary conditions) and ground definitions. For each configuration, the resulting VTA volume was computed to assess the clinical impact of modeling assumptions. Results: The FEM configuration implementing a Dirichlet (voltage) boundary condition on the active contact with a grounded implantable pulse generator (IPG) surface demonstrated the highest accuracy, achieving a Symmetric Mean Absolute Percent Error (SMAPE) of less than 9% across all contact levels. In contrast, conventional current-controlled simulations employing Neumann boundary conditions with disparate ground definitions substantially overestimated electric field spread. Suboptimal boundary condition selection resulted in an approximate 67% overestimation of VTA volume (137 mm3 vs. 82 mm3) relative to the experimentally validated model. Significance: Although clinical DBS systems operate as current sources, standard Neumann (current density) boundary conditions do not adequately represent the equipotential behavior of the electrode-tissue interface, resulting in nearly a two-fold error in predicted VTA volume. To improve the validity of predictive clinical models, we recommend the use of Dirichlet boundary conditions derived from the device operating impedance (V= Itarget × Zmeasured) rather than conventional current density specifications.

  • Open Access

    Comparative study of radiofrequency heating in deep brain stimulation devices during MRI at 1.5 T and 0.55 T: Challenging the assumption of safety at low field strengths

    by Bhumi Bhusal, Pia Panravi Sanpitak, Fuchang Jiang, Jacob Richardson, Nicole Seiberlich, Joshua M. Rosenow, Behzad Elahi, Laleh Golestanirad

    Purpose: Low‐field MRI has been assumed to be implant‐friendly based on limited studies. However, radiofrequency (RF)–induced heating due to an implant is a complex resonance phenomenon, highly dependent on the implant's configurations and applied RF frequencies. This study aims to evaluate the RF heating of deep brain stimulation (DBS) implants during MRI at low field strengths compared with higher‐field 1.5T MRI. Methods: A commercial DBS implant was used in full system as well as lead‐only configurations to evaluate and compare RF heating during MRI at 0.55 T and 1.5 T. The transfer function of the device was measured and validated at each of the frequencies, which was then used for prediction of RF heating with realistic DBS configurations at head, chest, and abdomen imaging landmarks. Results: For the lead‐only case, the RF heating due to the DBS was substantially smaller during imaging at 0.55 T compared with that at 1.5 T. However, for the full DBS system (longer implant), the RF heating at 0.55 T was comparable to, and for some cases even higher than, that at 1.5 T, reaching a level that poses risk of tissue damage in patients. Conclusions: Although RF heating generally tends to be lower at low‐field MRI, the case with longer implanted leads demands extra caution, due to the higher possibility of matching resonant condition at low‐field‐strength frequencies. Thus, specific risk evaluation for each implant and configuration is required rather than assuming that lower field strength imaging is safer.


  • Open Access

    Modifying the trajectory of epicardial leads can substantially reduce MRI‐induced RF heating in pediatric patients with a cardiac implantable electronic device at 1.5T

    by Fuchang Jiang, Bhumi Bhusal, Bach Nguyen, Michael Monge, Gregory Webster, Daniel Kim, Giorgio Bonmassar, Andrada R. Popsecu, Laleh Golestanirad

    Purpose: After epicardial cardiac implantable electronic devices are implanted in pediatric patients, they become ineligible to receive MRI exams due to an elevated risk of RF heating. We investigated whether simple modifications in the trajectories of epicardial leads could substantially and reliably reduce RF heating during MRI at 1.5 T, with benefits extending to abandoned leads.Methods: Electromagnetic simulations were performed to assess RF heating of two common 35‐cm epicardial lead trajectories exhibiting different degrees of coupling with MRI incident electric fields. Experiments in anthropomorphic phantoms implanted with commercial cardiac implantable electronic devices confirmed the findings. Both electromagnetic simulations and experimental measurements were performed using head‐first and feet‐first positioning and various landmarks. Transfer function approach was used to assess the performance of suggested modifications in realistic body models.Results: Simulations (head‐first, chest landmark) of a 35‐cm epicardial lead with a trajectory where the excess length of the lead was looped and placed on the inferior surface of the heart showed an 87‐fold reduction in the 0.1 g–averaged specific absorption rate compared with the lead where the excess length was looped on the anterior surface. Repeated experiments with a commercial epicardial device confirmed this. For fully implanted systems following low–specific absorption rate trajectories, there was a 16‐fold reduction in the average temperature rise and a 28‐fold reduction for abandoned leads. The transfer function method predicted a 7‐fold reduction in the RF heating in 336 realistic scenarios.Conclusion: Surgical modification of epicardial lead trajectory can substantially reduce RF heating at 1.5 T, with benefits extending to abandoned leads.


  • Open Access

    A comparative study of MRI-induced RF heating in pediatric and adult populations with epicardial and endocardial implantable electronic devices

    by Fuchang Jiang, Bhumi Bhusal, Pia Sanpitak, Gregory Webster, Andrada Popescu, Daniel Kim, Giorgio Bonmassar, Laleh Golestanirad

    Patients with congenital heart defects, inherited arrhythmia syndromes, and congenital disorders of cardiac conduction often receive a cardiac implantable electronic device (CIED). At least 75% of patients with CIEDs will need magnetic resonance imaging (MRI) during their lifetime. In 2011, the US Food and Drug Administration approved the first MR-conditional CIEDs for patients with endocardial systems, in which leads are passed through the vein and affixed to the endocardium. The majority of children, however, receive an epicardial CIED, where leads are directly sewn to the epicardium. Unfortunately, an epicardial CIED is a relative contraindication to MRI due to the unknown risk of RF heating. In this work, we performed anthropomorphic phantom experiments to investigate differences in RF heating between endocardial and epicardial leads in both pediatric and adult-sized phantoms, where adult endocardial CIED was the control. Clinical Relevance—This work provides a quantitative comparison of MRI RF heating of epicardial and endocardial leads in pediatric and adult populations