FKFahrettin Fatih Kesmezacar

Fahrettin Fatih Kesmezacar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fahrettin Fatih Kesmezacar has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    DESIGN AND EVALUATION OF A HAND-ANATOMY-BASED 3D-PRINTED ERGONOMIC PEN GRIP

    by Özge Coşkun, Fahrettin Fatih Kesmezacar, Duygu Tunçman, Hamza Kurtkapan, Muhittin Onur Yaman

    This pilot study presents the design and evaluation of a personalized 3D-printed ergonomic pen grip aimed at reducing hand fatigue and improving grip efficiency during writing tasks. A custom pen grip was developed by creating a three-point grasp mould from the dominant hand of a healthy adult, which was digitized via 3D scanning, refined using CAD software, and printed using PLA filament with fused deposition modelling (FDM) technology. The participant completed writing tasks under three different conditions: at rest, after writing with the ergonomic grip, and after writing without it. Grip and pinch strengths were assessed using a hydraulic hand dynamometer and pinch meter. Findings revealed that the decrease in grip strength was smaller after writing with the ergonomic grip compared to the no-device condition. The participant reported less finger fatigue and greater comfort, although writing time was slightly longer when using the device. These results underscore the potential utility of personalized 3D-printed assistive devices in occupational rehabilitation, particularly for individuals experiencing hand fatigue or diminished grip capacity.

  • Open Access

    Baş-Boyun, Toraks ve Batın Bölgelerinde Bilgisayarlı Tomografi Çekimi Sırasında Radyasyon Maruziyeti: Korunma Stratejileri ve Doz Değerlendirmesi

    by Duygu Tunçman Kayaokay, Fahrettin Fatih Kesmezacar, Osman Günay, Mustafa Demir

    Bu çalışmada baş-boyun, toraks ve batın bölgelerinden yapılan bilgisayarlı tomografi (BT) taramalarında organ absorbe radyasyon dozları Termoluminesans Dozimetreler (TLD’ler) ile deneysel olarak ölçülmüştür. Amaç, kritik organ olarak bilinen dozların değerlendirilmesi ve radyasyondan korunma stratejilerinin geliştirilmesidir. Baş-boyun bölgesindeki organlar, genellikle orta seviyelerde dozlar almış olup, özellikle Glandula Thyroidea (24.95 ± 0.525 mGy) ve Glandula Parotidea (28.49 ± 1.34 mGy) gibi kritik organlar, uzun süreli sağlık etkilerine karşı duyarlıdır. Toraks bölgesindeki dozlar, Pulmonis (5.86 ± 0.1 mGy) ve Mammaria dextra (6.52 ± 0.7 mGy) gibi organlarda daha düşüktür, ancak düşük dozların kardiyovasküler sağlık üzerindeki potansiyel etkileri dikkate alınmalıdır. Batın bölgesinde ise, karaciğer (15.87 ± 1.6 mGy) ve böbrekler (15.26 ± 0.6 mGy) gibi organlar daha yüksek dozlar almıştır, bu da uzun vadeli kanser risklerinin arttığını göstermektedir. Bu bulgular, baş-boyun ve batın bölgelerinde organ koruma stratejilerinin önemini vurgulamaktadır. Sonuç olarak, elde edilen doz verileri, radyasyon maruziyetini minimize etmek için hastalar üzerinde daha dikkatli doz kontrolü yapılması gerektiğini ortaya koymaktadır. Ayrıca, TLDlerin kullanımı, BT taramalarında güvenli doz ölçümünü sağlamak ve gereksiz radyasyon maruziyetini önlemek için etkili bir yöntem olarak öne çıkmaktadır.

  • Open Access

    On cranial CT imaging: The role of low-dose protocols in enhancing patient safety and reducing radiation exposure

    by Duygu Tunçman Kayaokay, Fahrettin Fatih Kesmezacar, Osman Günay, Songül Çavdar Karaçam, Ali Demirci, Mustafa Demir, Ghada Almisned, Huseyin Ozan Tekin

  • Open Access

    Quantification of Radiation Exposure of the Lungs and Liver in Computed Tomography (CT): A Dose Level Analysis

    by Aleyna Gürçalar, Ayşe Beyza Cuma, Feyzanur Abuş, Osman Günay, Duygu Tunçman, Fahrettin Fatih Kesmezacar, Mustafa Demir

    This study looked at the radiation dose that a patient's liver and lungs received while undergoing computed tomography (CT) procedures. Radiation exposure was simulated and measured using the TLD-100 thermoluminescent dosimeter and the Alderson Rando Phantom (ART). Each organ had three scans in order to assess the impact on essential organs, and the radiation dose to which the organs were subjected was estimated by taking the arithmetic average of the three images. By offering insightful information on maximizing radiation exposure for patient safety during computed tomography imaging, the study improves medical practices and procedures.

  • Open Access

    Head and Neck Imaging with a Dental CBCT Device: Comparison of 360° and 180° Rotation Angles in Effective Dose and Quantitative Image Quality in a Phantom Study

    by Hakan Amasya, Osman Günay, Fatih Kesmezacar, Duygu Tunçman Kayaokay, Nami Yeyin, Eylem Kekeç, Tülin Zengin, Kaan Orhan, Songül Çavdar Karaçam, Mustafa Demir

    Objectives: This study aims to investigate the effect of full- and half-rotation angles on patient radiation dose and quantitative image quality in CBCT imaging of the head and neck region. Methods: A total of 67 TLDs were used for the dosimetry of 16 different regions in the head and neck slices of the anthropometric phantom. The Hyperion X9 Pro (MyRay, Cefla, Imola, Italy) CBCT device was used with a 90 kV pulsed beam and a 13x16e FOV size. Two separate imaging modes (Regular 360 0 and Quick 180 0) were tested, and the mA was determined by the software. Effective doses (EDs) were calculated using the coefficients recommended by ICRP 103 (2007). For the quantitative image quality tests, three VOIs were manually selected for three separate densities in image slices selected from the mandible, maxilla, and paranasal sinus regions of both volumes separately. Pixel values were averaged, and (SNR), contrast-to-noise ratio (CNR), and uniformity tests were conducted. Results: In 360 0, ED was calculated as 1.903 mSv and the highest absorbed dose was found in the oral mucosa (1.566 mSv). In 180 0, ED was calculated as 1.123 mSv and the highest absorbed dose was found in the right temporal squamous region (0.984 mSv). The reduction in ED was found to be 41% for full- and half-rotation angles. Quick/Regular ratios for SNR and CNR were changed between 0.83-0.91. Conclusion: The magnitude of reduction in ED was found to be higher than the quantitative image quality; however, the impact of this change on diagnosis should be analyzed according to the imaging purpose.


  • Hepatopulmonary Shunt Ratio Verification Model for Transarterial Radioembolization

    by Nami Yeyin, Fahrettin Fatih Kesmezacar, Duygu Tunçman, Özge Demir, Lebriz Uslu-Beşli, Osman Günay, Mustafa Demir

    Introduction: The most important toxicity of transarterial radioembolization therapy applied in liver malignancies is radiation pneumonitis and fibrosis due to hepatopulmonary shunt of Yttrium-90 (90Y) microspheres. Currently, Technetium-99m macroaggregated albumin (99mTc-MAA) scintigraphic images are used to estimate lung shunt fraction (LSF) before treatment. The aim of this study was to create a phantom to calculate exact LFS rates according to 99mTc activities in the phantom and to compare these rates with LSF values calculated from scintigraphic images. Materials and Methods: A 3D-printed lung and liver phantom containing two liver tumors was developed from Polylactic Acid (PLA) material, which is similar to the normal-sized human body in terms of texture and density. Actual %LSFs were calculated by filling phantoms and tumors with 99mTc radionuclide. After the phantoms were placed in the water tank made of plexiglass material, planar, SPECT, and SPECT/CT images were obtained. The actual LSF ratio calculated from the activity amounts filled into the phantom was used for the verification of the quantification of scintigraphic images and the results obtained by the Simplicity90YTM method. Results: In our experimental model, LSFs calculated from 99mTc activities filled into the lungs, normal liver, small tumor, and large tumor were found to be 0%, 6.2%, 10.8%, and 16.9%. According to these actual LSF values, LSF values were calculated from planar, SPECT/CT (without attenuation correction), and SPECT/CT (with both attenuation and scatter correction) scintigraphic images of the phantom. In each scintigraphy, doses were calculated for lung, small tumor, large tumor, normal liver, and Simplicity90YTM. The doses calculated from planar and SPECT/CT (NoAC+NoSC) images were found to be higher than the actual doses. The doses calculated from SPECT/CT (with AC+with SC) images and Simplicity90YTM were found to be closer to the real dose values. Conclusion: LSF is critical in dosimetry calculations of 90Y microsphere therapy. The newly introduced hepatopulmonary shunt phantom in this study is suitable for LSF verification for all models/brands of SPECT and SPECT/CT devices.


  • Meslek Yüksekokulu Öğrencilerinin Organ, Kadavra Ve Plazma Bağışı Hakkında Bilgi Ve Tutumları

    by Fahrettin Fatih Kesmezacar, Elif Işik Demi̇rarslan, Özgü Kesmezacar

    Amaç: Bu çalışma ile meslek yüksekokulu öğrencilerinin, organ, kadavra ve plazma bağışı hakkındaki bilgi ve tutumlarını araştırmak amacıyla yapılmıştır. Gereç ve Yöntem: İki farklı üniversitenin sağlık ve sosyal hizmetler meslek yüksekokulunda okuyan 633 öğrenciye sosyodemografik özellikler, organ bağışı ve plazma bağışı ile ilgili sorulardan oluşan anket uygulanmıştır. Veriler uzaktan online yöntemle toplanmıştır. Verilerin Analizi Epiİnfo v.7.2.5.0 programında yapılmış olup, frekans dağılımları ve ki-kare testi analizlerde kullanılmıştır. Bulgular: Katılımcıların %41,5’i sağlık, %58,5’i sosyal programlarda öğrenim görmektedir. Öğrencilerin%3,2’si organlarını bağışlarken %80,1’inin kadavradan organ bağışı hakkında bilgisi olduğu ve %68,8’i bu bilgiyi medya ve internetten duyduklarını, %81’inin organ bağışının hem canlıdan hem de ölüden olabileceğini bildiği, %68,7’ sinin öldükten sonra organlarını bağışlamayı düşündüklerini, %36,4’ünün organ bağışı konusunda yeterli bilgisinin olmadığı için bağış düşünmediği, %84,5’unun gerekli durumda organ nakli kabul edeceğini belirtmişlerdir. Katılımcıların %48,8’ inin kadavra bağışı bilgisi olduğu, %60,2’sinin bu bilgiyi medya/internetten öğrendiği, %66’sının kendisini kadavra olarak bağışlamayı düşünmediği belirlenmiştir. Katılımcıların %66’sı plazma bağışını bildiği, %61,5’inin bu bilgiyi medya/internetten öğrendiği, %63,8’inin plazma bağışlamayı düşündüğü, %70,8’inin bir insanın hayatını kurtarmak için plazma bağışlayabileceği belirlenmiştir. Ayrıca Covid-19 geçirmenin organ, kadavra ve plazma bağışına anlamlı bir değişiklik yapmadığı tespit edilmiştir. Sonuç: Araştırmada Sosyal medya ve internetin bilgi edinmede etkili olduğu, katılımcıların bağış konusunda bilgilerinin olduğu fakat bağış yapmada ya da düşünmede kararsız kaldıkları sonuçlarına ulaşılmıştır.

  • Open Access

    ANATOMİ DERSİ OKUMAK ÖNLİSANS ÖĞRENCİLERİNDE KADAVRA BAĞIŞI GÖRÜŞÜNDE FARK YARATIYOR MU?

    by Fahrettin Fatih Kesmezacar

    Amaç; Çalışmanın amacı meslek yüksekokulu öğrencilerinin kadavra bağışı hakkındaki bilgi ve tutumlarının değerlendirilip; anatomi dersi alma ve sosyodemografik faktörlerin bilgi ve tutumlarına olan etkisinin araştırılmasıdır. Yöntem; Kesitsel tipte tanımlayıcı bir araştırma olup, bir üniversitenin sağlık ve sosyal hizmetler meslek yüksekokulunda öğrenim gören öğrencilerine kadavra bağışı, anatomi dersi görme, ve sosyo-demografik özelliklerine yönelik sorular içeren anket uygulanmıştır. Bulgular; Çalışmaya toplam 471 öğrenci katılmıştır. Öğrencilerin %55,9’u anatomi dersi görmenin bedenini kadavra olarak bağışlama düşüncesini değiştirmediğini; % 9,9’u ise olumlu yönde etkilediğini belirtmiştir. Kadavra bağışı hakkında bilgi edinilen kaynak olarak tüm öğrencilerde en fazla (%64,4) medya/internet belirtilmiştir. Bilgi edinme kaynağı konusunda anatomi dersi alanlar ve almayanlar incelendiğinde; dersi almayanların büyük çoğunluğunun medya/internetten (%77,9), dersi alanların ise medya/internet (%50,9) ve okul/ders/seminerlerden (%44,6) aynı oranda bilgi edindiği görülmüştür. Anatomi dersi alıp kadavra donörü olmak isteyen öğrenci oranı % 15,3 iken, dersi almayanlarda oran % 6,4idi. birinci derece akrabalarını donör olarak bağışlama oranı, dersi alanlarda %10,4, dersi almayanlarda ise %2,8 olarak bulundu. Öğrencilerde, Allah inancı olması beden bağışı isteğini azaltırken, teorik anatomi dersi almanın bu isteği 2,9 kat artırdığı görüldü. Sonuçlar: Sağlık alanında eğitim görenlerde teorik anatomi dersinin kadavra bağışına olumlu etki ettiği, anatomi ders müfredatlarına da kadavra donörlüğüne yönelik düzenlemenin gerekliliği görüldü. Anatomi dersi almayanlarda ise, konuyla ilgili en fazla bilgi kaynağının medya/internet olmasından dolayı, sosyal medyanın aktif olarak kullanılması düşünülmelidir.

  • Open Access

    Determining the Radiation Dose Levels the Kidney is Exposed to in Kidney Stone Fragmentation Procedures

    by Aycan Sengul, Osman Gunay, Eylem Kekeç, Tulin Zengin, Duygu Tuncman, Fahrettin Fatih Kesmezacar, Nami Yegin, Ozge Demir, Hilmi Aksoy

    This study examines the radiation dose levels to which the kidney is exposed during kidney stone fragmentation procedures that utilize scopy imaging. The assessment was conducted using the Alderson Rando phantom and Thermoluminescent Dosimeter (TLD). The study examined various exposure parameters and measured the radiation dose to the kidney over time. The results suggest a direct correlation between exposure duration and radiation dose, emphasizing the need to monitor radiation levels during fluoroscopic interventions, especially due to the kidneys' sensitivity to radiation. Future research should concentrate on optimizing scopy settings to minimize radiation exposure while ensuring diagnostic accuracy and patient safety.


  • Open Access

    ERGONOMIC DISSECTION SCISSORS

    by Fahrettin Fatih Kesmezacar, Atiye Bahar Mergen

    Ergonomi, temel olarak insanın makineye değil makinenin insana uyumunu amaç edinir. Geleneksel diseksiyon makasları tek bir düzlemde olup, sap ve gövde bölümlerinde herhangi bir eğim bulunmaz. Bunun sonucunda makası kullanan kişi sürekli olarak bileğini bükmesine bağlı olarak ağrı ve strese maruz kalır. Standart makaslarda el nadiren nötr pozisyona gelir. Diseksiyonda dokular kat kat birbirinden ayrılarak incelenir. Dokuların birbirinden ayrılma işlemi diseksiyon makasları, oluklu sonda ve bisturi ile yapılır. Ergonomik diseksiyon makasının tasarımının temel amacı, sap kısmı ve kulplarının insan anatomisine uygun ergonomik yapıda olmasıdır. Makasın sap bölümde; kulplar ve kulp sapları tamamen parmak ergonomisine uygun hale getirilmiştir. Ayrıca ergonominin temeli olan aletin bükülmesi gerekliliği olarak sap bölümü eli nötr pozisyonda kalabilecek şekilde değiştirilmiştir. Makasın, kulpların bulunduğu sap bölümünde parmaklarla, el bileği ile ve makas-zeminle olan ilişkileri tasarımda temeli oluşturmuştur. Diseksiyonun sadece makasla yapılmadığı ve kullanılan diğer aletlerinde makasa nasıl adapte edileceği de düşünülmüştür. Çalışmada bahsedilen tasarım patent almış ve tescillenmiştir. Makas ve oluklu sonda aynı malzemede olması kullanıcıya diseksiyon sırasında oldukça rahatlık sağlayacaktır.