HLHongyan Liu

Hongyan Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hongyan Liu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A multi-cascade deep learning method for physiological micro-vibration signal enhancement: A case for OSA monitoring

    by Hongyan Liu, Qian Wang, Xiaoxin Lan, Xuefeng Song, Yuhang Wang, Haibo Yuan, Tianyuan Hou, Yi Xin


  • A vital sign signal noise suppression method for wearable piezoelectric devices

    by Yi Xin, Hongyan Liu, Tianyuan Hou, Xuefeng Song, Junye Tong, Meng Cui, Meina Li, Jingjie Zhai

    This paper tackles the problem of noise suppression during vital sign signal monitoring. Physiological signal monitoring is a significant and promising medical monitoring method, and wearable medical monitoring devices based on piezoelectric polymer sensors are a trending way for their advantages of being flexible in the shape, portable to use, and comfortable to wear. However, this raises the question that the measured signal contains much more noise components. To avoid the following shortcoming of low signal to noise ratio (SNR), a noise suppression method based on improved wavelet threshold and empirical mode decomposition combined with singular value decomposition (SVD) screening the intrinsic mode function (IMF) components is proposed. A wavelet transform is first used under the combination of hard and soft thresholds to focus the target range in the low-frequency region where the energy of the physiological signal is concentrated. Then, a complete ensemble empirical mode decomposition is used to decompose the signal effectively, which can resist the influence of random noises. Meanwhile, a SVD decomposition procedure was used to filter out the lower correlated IMF components to retain the validity of the original signal. We verified the effectiveness of the proposed method through simulated and measured experiments as well as the advantages and disadvantages of the algorithm compared with other physiological signal denoising algorithms through SNR filtering results, power spectrum distribution, and other perspectives. The results proved that the proposed method could effectively remove more detailed noise and improve the SNR of the signal efficiently, which is more conducive to the demand for auxiliary medical diagnosis in the future.


  • All Solid-State Electrode With Low Contact Resistance and Low Polarization for Measuring the Electrical Properties of Rocks

    by Yi Xin, Yuhang Wang, Xuefeng Song, Junye Tong, Tianyuan Hou, Hongyan Liu, Meng Cui

    Accurate measurement of rock electrical properties plays a crucial role in resource exploration and geological exploration. But there are kinds of problems with traditional rock measuring electrodes including high contact resistance, high electrode polarization, low stability and so on. To solve these problems, we designed and fabricated an all solid-state electrode with low contact resistance, low polarizability and high stability. The electrode consists of silver (Ag) and silver chloride (AgCl). To reduce the contact resistance between the electrode and rocks, the electrode was fabricated by powder sintering and repressing, and a scanning electron microscope (SEM) showed that the surface of the electrodes was multi-holes and coarse which is beneficial to reduce contact resistance. In addition, the Ag and AgCl mixture was prepared in the polyvinyl pyrrolidone (PVP) gel, which reduced the particle size of the AgCl and led to a low polarization degree of the electrode. An experimental system for evaluation and characterization was designed to measure the basic characteristics, stability, contact resistance and polarization of the electrodes, which are essential features and will affect the accuracy of electrical measurement. And the copper (Cu) electrode is the reference electrode. The results showed that the maximum resistance of the electrode pair is lower than 0.13 Ω. Through the measurements of core samples with different moisture content, contact resistances are lower than the Cu electrodes by at least 74%, and the accuracy of resistivity measurement is increased by more than 25%. The polarization degree of the electrode is reduced by more than 65%. After multiple measurements, the electrodes still maintain great performance and the uncertainty in measurement keeps at a low level. These characteristics will improve the measuring accuracy of the core electrical properties remarkably. Therefore, this research will promote the study of petrophysical and the exploration of mineral resources.