Yuhang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuhang Wang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Yi Xin
College of Instrumentation and Electrical Engineering, Jilin University, Changchun 130061, China
9 shared publications - Tianyuan Hou
College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China
6 shared publications - Junye Tong
College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China
4 shared publications - Xuefeng Song
College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China
4 shared publications - Zhenming Piao
College of Instrumentation and Electrical Engineering, Jilin University, Changchun 130012, China
4 shared publications - Rui Li
Southern Marine Science and Engineering Guangdong Laboratory (Zhanjiang), Zhanjiang 524000, China
3 shared publications
Latest Publications
- Open Access
A Biomimetic Tympanic Cavity PVDF Hydrophone for Low-Frequency Bioacoustic Monitoring in Marine Aquaculture
Underwater acoustic monitoring is a critical technology for marine resource development and modern aquaculture. The performance of acoustic sensors directly determines the effectiveness of biological behavior tracking in complex marine environments. This paper presents the design, fabrication, and characterization of a custom hydrophone utilizing a polyvinylidene fluoride (PVDF) piezoelectric film configured in a biomimetic tympanic cavity structure. Operating on the direct piezoelectric effect, the device employs a pre-tensioned PVDF diaphragm integrated with a dedicated charge amplifier circuit to condition high-impedance signals. Laboratory calibrations demonstrate a stable frequency response (with a sensitivity variation within ±1 dB) in the low-frequency range (1–200 Hz) with an average acoustic pressure sensitivity of approximately −206 dB (re 1 V/μPa), providing a higher relative voltage gain compared to a commercial reference hydrophone with a nominal sensitivity of −210 dB (re 1 V/μPa). Furthermore, extensive field evaluations were conducted in a marine net pen to analyze acoustic data across multiple fish feeding scenarios (baseline, pre-feeding, active feeding, and post-feeding). The proposed custom hydrophone exhibited a superior dynamic range and successfully locked onto a 24.4 Hz Golden Pompano (Trachinotus blochii) bioacoustic signature, maintaining remarkable feature stability even after active feeding ceased. This study validates the efficacy of the biomimetic PVDF hydrophone for low-frequency acoustic detection, providing a robust hardware foundation for automated behavioral recognition systems in aquaculture.
Open AccessA Biomimetic Tympanic Cavity PVDF Hydrophone for Low-Frequency Bioacoustic Monitoring in Marine Aquaculture
Underwater acoustic monitoring is a critical technology for marine resource development and modern aquaculture. The performance of acoustic sensors directly determines the effectiveness of biological behavior tracking in complex marine environments. This paper presents the design, fabrication, and characterization of a custom hydrophone utilizing a polyvinylidene fluoride (PVDF) piezoelectric film configured in a biomimetic tympanic cavity structure. Operating on the direct piezoelectric effect, the device employs a pre-tensioned PVDF diaphragm integrated with a dedicated charge amplifier circuit to condition high-impedance signals. Laboratory calibrations demonstrate a stable frequency response (with a sensitivity variation within ±1 dB) in the low-frequency range (1–200 Hz) with an average acoustic pressure sensitivity of approximately −206 dB (re 1 V/μPa), providing a higher relative voltage gain compared to a commercial reference hydrophone with a nominal sensitivity of −210 dB (re 1 V/μPa). Furthermore, extensive field evaluations were conducted in a marine net pen to analyze acoustic data across multiple fish feeding scenarios (baseline, pre-feeding, active feeding, and post-feeding). The proposed custom hydrophone exhibited a superior dynamic range and successfully locked onto a 24.4 Hz Golden Pompano (Trachinotus blochii) bioacoustic signature, maintaining remarkable feature stability even after active feeding ceased. This study validates the efficacy of the biomimetic PVDF hydrophone for low-frequency acoustic detection, providing a robust hardware foundation for automated behavioral recognition systems in aquaculture.
- Open Access
Low-Frequency Piezoelectric Hydrophone with High Sensitivity Based on a Piston Structure
Low-frequency hydrophones are used to detect underwater low-frequency acoustic signals and are widely applied in marine science, resource exploration, environmental monitoring, and military operations. Their primary advantage lies in the fact that low-frequency acoustic waves experience less attenuation in water, enabling long-distance detection. This characteristic makes them indispensable for long-range and wide-area sensing. In this study, a piston-structured hydrophone using a stack of lead zirconate titanate (PZT) piezoelectric ceramic sheets is designed. Finite element simulation analysis is used to derive the output voltage variation in the piezoelectric ceramic stack as a function of its thickness and end-face diameter. The piston-structured hydrophone is then designed accordingly. Results show that the piston structure, combined with the longitudinal stacking of PZT piezoelectric ceramic sheets, enhances the sensitivity of the piezoelectric hydrophone. The prepared hydrophone has a directivity of 360° in the operating frequency range of 1 Hz to 1 kHz, as well as a flat frequency response and high sensitivity of −161 dB. These research results indicate that the proposed sonar design provides valuable reference for the development of low-frequency sonar with higher sensitivity, which is of great significance to the development of marine science.
Open AccessLow-Frequency Piezoelectric Hydrophone with High Sensitivity Based on a Piston Structure
Low-frequency hydrophones are used to detect underwater low-frequency acoustic signals and are widely applied in marine science, resource exploration, environmental monitoring, and military operations. Their primary advantage lies in the fact that low-frequency acoustic waves experience less attenuation in water, enabling long-distance detection. This characteristic makes them indispensable for long-range and wide-area sensing. In this study, a piston-structured hydrophone using a stack of lead zirconate titanate (PZT) piezoelectric ceramic sheets is designed. Finite element simulation analysis is used to derive the output voltage variation in the piezoelectric ceramic stack as a function of its thickness and end-face diameter. The piston-structured hydrophone is then designed accordingly. Results show that the piston structure, combined with the longitudinal stacking of PZT piezoelectric ceramic sheets, enhances the sensitivity of the piezoelectric hydrophone. The prepared hydrophone has a directivity of 360° in the operating frequency range of 1 Hz to 1 kHz, as well as a flat frequency response and high sensitivity of −161 dB. These research results indicate that the proposed sonar design provides valuable reference for the development of low-frequency sonar with higher sensitivity, which is of great significance to the development of marine science.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
High-Performance Piezoelectric Sensors Based on PVDF/CB Nanofibers for Structural Health Monitoring
Structural health monitoring (SHM) plays a vital role in engineering by enhancing the safety and longevity of structures through the use of various sensors. This study presents a flexible polyvinylidene fluoride/carbon black (PVDF/CB) nanofiber sensor for SHM applications. The sensor was fabricated via electrospinning and demonstrated strong piezoelectric performance. Incorporation of CB effectively promoted the transformation of$\alpha $ -phase to the piezoelectric$\beta $ -phase by 6.1% compared to pure PVDF nanofibers. In addition, the sensitivity of the piezoelectric nanofibers was increased from 0.75 to 2.05 V/N due to the addition of CB. To further enhance SHM accuracy, a multilayer perceptron (MLP) neural network optimized with the adaptive moment estimation (Adam) algorithm was trained using simulated model frequency data. The proposed SHM system integrates the PVDF/CB nanofiber sensors, trained MPL model, and signal processing module for modal frequency extraction. This system enables real-time damage detection while the structure under investigation is subjected to vibration. The system achieved a minimum detection error of 2.15 mm, and a stable detection rate of 95% (relative standard deviation (RSD) = 3.6%). These findings suggest that this flexible PVDF/CB sensor offers promising potential for real-time SHM applications.- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
High-Performance Piezoelectric Sensors Based on PVDF/CB Nanofibers for Structural Health Monitoring
Structural health monitoring (SHM) plays a vital role in engineering by enhancing the safety and longevity of structures through the use of various sensors. This study presents a flexible polyvinylidene fluoride/carbon black (PVDF/CB) nanofiber sensor for SHM applications. The sensor was fabricated via electrospinning and demonstrated strong piezoelectric performance. Incorporation of CB effectively promoted the transformation of$\alpha $ -phase to the piezoelectric$\beta $ -phase by 6.1% compared to pure PVDF nanofibers. In addition, the sensitivity of the piezoelectric nanofibers was increased from 0.75 to 2.05 V/N due to the addition of CB. To further enhance SHM accuracy, a multilayer perceptron (MLP) neural network optimized with the adaptive moment estimation (Adam) algorithm was trained using simulated model frequency data. The proposed SHM system integrates the PVDF/CB nanofiber sensors, trained MPL model, and signal processing module for modal frequency extraction. This system enables real-time damage detection while the structure under investigation is subjected to vibration. The system achieved a minimum detection error of 2.15 mm, and a stable detection rate of 95% (relative standard deviation (RSD) = 3.6%). These findings suggest that this flexible PVDF/CB sensor offers promising potential for real-time SHM applications.- Open Access
Preparation of Carbon Fiber Electrodes Modified with Silver Nanoparticles by Electroplating Method
To solve the problems of carbon fiber (CF) electrodes, including poor frequency response and large potential drift, CFs were subjected to a roughening pretreatment process combining thermal oxidation and electrochemical anodic oxidation and then modified with Ag nanoparticles (AgNPs) using electroplating to prepare a CF electric field sensor. The surface morphology of the as-prepared AgNP-CF electric field sensor was characterized via optical microscopy, scanning electron microscopy, XPS, and energy-dispersive spectroscopy, and its impedance, polarization drift, self-noise, and temperature drift values were determined. Results show that the surface modification of the AgNP-CF electric field sensor is uniform, and its specific surface area is considerably increased. The electrode potential drift, characteristic impedance, self-noise, and temperature drift are 52.1 µV/24 h, 3.6 Ω, 2.993 nV/√Hz@1 Hz, and less than 70 µV/°C, respectively. Additionally, the AgNP-CF electric field sensor demonstrates low polarization and high stability. In field and simulated ocean tests, the AgNP-CF electrode exhibits excellent performance in the field and underwater environments, which renders it promising for the measurement of the ocean and geoelectric fields owing to its advantages, such as low noise and high stability.
Open AccessPreparation of Carbon Fiber Electrodes Modified with Silver Nanoparticles by Electroplating Method
To solve the problems of carbon fiber (CF) electrodes, including poor frequency response and large potential drift, CFs were subjected to a roughening pretreatment process combining thermal oxidation and electrochemical anodic oxidation and then modified with Ag nanoparticles (AgNPs) using electroplating to prepare a CF electric field sensor. The surface morphology of the as-prepared AgNP-CF electric field sensor was characterized via optical microscopy, scanning electron microscopy, XPS, and energy-dispersive spectroscopy, and its impedance, polarization drift, self-noise, and temperature drift values were determined. Results show that the surface modification of the AgNP-CF electric field sensor is uniform, and its specific surface area is considerably increased. The electrode potential drift, characteristic impedance, self-noise, and temperature drift are 52.1 µV/24 h, 3.6 Ω, 2.993 nV/√Hz@1 Hz, and less than 70 µV/°C, respectively. Additionally, the AgNP-CF electric field sensor demonstrates low polarization and high stability. In field and simulated ocean tests, the AgNP-CF electrode exhibits excellent performance in the field and underwater environments, which renders it promising for the measurement of the ocean and geoelectric fields owing to its advantages, such as low noise and high stability.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Ultra-low noise nanoporous Ag/AgCl electric field sensor for telluric electric field detection
This paper presents an ultra-low noise nanoporous Ag/AgCl electric field sensor fabricated using a sol in situ composite method, aiming to address the issues of high noise and significant drift encountered in traditional electric field sensors during low-frequency signal measurements. By utilizing polyvinylpyrrolidone (PVP) sol to regulate the nucleation process of AgCl and combining it with nano-silver powder, nanoscale Ag/AgCl particles were prepared. Through the use of NaCl as a pore-forming agent, an electrode with a porous structure was developed. A double-layer porous semi-permeable membrane encapsulation structure is employed, which protects the electrode from external environmental damage without compromising its performance, thereby improving its stability and lifespan. Experimental results demonstrate that the electrode exhibits a low source resistance of 0.13 Ω, the 24-h drift of less than 12 μV, and the self-noise of 0.874 nV/√Hz@1 Hz, with the working frequency band ranging from 0.1 Hz to 100 kHz, showcasing excellent frequency response and stability. Field tests in electrical prospecting further validated the electrode's high accuracy and reliability in measuring apparent resistivity, apparent polarizability, and spontaneous potential. This technological breakthrough provides robust technical support for deep resource exploration and long-term geoelectric field monitoring.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Ultra-low noise nanoporous Ag/AgCl electric field sensor for telluric electric field detection
This paper presents an ultra-low noise nanoporous Ag/AgCl electric field sensor fabricated using a sol in situ composite method, aiming to address the issues of high noise and significant drift encountered in traditional electric field sensors during low-frequency signal measurements. By utilizing polyvinylpyrrolidone (PVP) sol to regulate the nucleation process of AgCl and combining it with nano-silver powder, nanoscale Ag/AgCl particles were prepared. Through the use of NaCl as a pore-forming agent, an electrode with a porous structure was developed. A double-layer porous semi-permeable membrane encapsulation structure is employed, which protects the electrode from external environmental damage without compromising its performance, thereby improving its stability and lifespan. Experimental results demonstrate that the electrode exhibits a low source resistance of 0.13 Ω, the 24-h drift of less than 12 μV, and the self-noise of 0.874 nV/√Hz@1 Hz, with the working frequency band ranging from 0.1 Hz to 100 kHz, showcasing excellent frequency response and stability. Field tests in electrical prospecting further validated the electrode's high accuracy and reliability in measuring apparent resistivity, apparent polarizability, and spontaneous potential. This technological breakthrough provides robust technical support for deep resource exploration and long-term geoelectric field monitoring.
- 15 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
All-Solid Ultralow Noise Electric Field Sensor Based on the Sol Adhesion Method for Telluric and Marine Electrode Field Detection
The sol adhesion method prepared an all-solid ultralow noise electric field sensor. Compared with the sintering method, electrolysis method, and ball milling method, the content of Ag (silver) and AgCl (silver chloride) stays at a high-level amount, the mixture is more uniform and there are no impurities introduced in the fabrication process. Some experiments were designed to characterize the basic properties and electrochemical characteristics of the electrode. Scanning electron microscope (SEM) shows the produced Ag/AgCl (silver and silver chloride) has small particle sizes and a large contact area. The potential drifts of electrodes are less than$15~\mu $ V. The self-potential is less than$80~\mu $ V. Self-noise of the electrode is 1.99 nV/$\surd $ Hz@1 Hz. Meanwhile, the electrode responds well to electric field signals from 0.1 Hz to 3 kHz and can detect small amplitude signals to 2 mV without distortion. The electrode has the advantages of low impedance, low noise, high sensitivity, and high stability. The self-potential test showed the Ag/AgCl electrodes spent less than 20 min to reach stability is at least three times faster than that of Cu, Ag, Pb/PbCl, and stainless-steel electrodes. Stability potential and range drift are at least 98% and 93% lower than that of other electrodes. In the telluric test, the signal amplitude is at least four times of Ag and Pb/PbCl electrodes. In the marine test, the signal amplitude value is 4 mV level with the noise amplitude value is 0.06 mV level. It shows the good performance of the electrodes. This study is of great significance in accurately measuring marine and telluric electric fields.- 15 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
All-Solid Ultralow Noise Electric Field Sensor Based on the Sol Adhesion Method for Telluric and Marine Electrode Field Detection
The sol adhesion method prepared an all-solid ultralow noise electric field sensor. Compared with the sintering method, electrolysis method, and ball milling method, the content of Ag (silver) and AgCl (silver chloride) stays at a high-level amount, the mixture is more uniform and there are no impurities introduced in the fabrication process. Some experiments were designed to characterize the basic properties and electrochemical characteristics of the electrode. Scanning electron microscope (SEM) shows the produced Ag/AgCl (silver and silver chloride) has small particle sizes and a large contact area. The potential drifts of electrodes are less than$15~\mu $ V. The self-potential is less than$80~\mu $ V. Self-noise of the electrode is 1.99 nV/$\surd $ Hz@1 Hz. Meanwhile, the electrode responds well to electric field signals from 0.1 Hz to 3 kHz and can detect small amplitude signals to 2 mV without distortion. The electrode has the advantages of low impedance, low noise, high sensitivity, and high stability. The self-potential test showed the Ag/AgCl electrodes spent less than 20 min to reach stability is at least three times faster than that of Cu, Ag, Pb/PbCl, and stainless-steel electrodes. Stability potential and range drift are at least 98% and 93% lower than that of other electrodes. In the telluric test, the signal amplitude is at least four times of Ag and Pb/PbCl electrodes. In the marine test, the signal amplitude value is 4 mV level with the noise amplitude value is 0.06 mV level. It shows the good performance of the electrodes. This study is of great significance in accurately measuring marine and telluric electric fields.- 15 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
High-Temperature Resistance BiScO₃–PbTiO₃ Nanofiber Overpressure Sensor for Free-Field Shock Waves Testing
In the process of developing energetic materials, it is necessary to evaluate the explosive power of energetic materials, especially the destructive effect of shock waves. Overpressure measurement is an important method to evaluate the power of shock waves. This article proposes an overpressure sensor based on BiScO3–PbTiO3 (BSPT) piezoelectric ceramic nanofibers (NFs). The BSPT NF sensor has the characteristics of high-temperature and high-pressure impact resistance and can be used for shock wave measurement. Experimental results show that the BSPT NF sensor has high-temperature stability; the sensitivity remains above 5.4 V/N at 60 °C–220 °C, and its sensitivity is still higher than 3.7 V/N at 240 °C. In addition, the BSPT NFs overpressure sensor has excellent overload resistance, measuring up to 65 kPa of overpressure without any damage when the trinitrotoluene (TNT) equivalent is 9.6 kg and the sensor is 4 m away from the explosion center. The results indicate that the BSPT NFs overpressure sensor has great application potential in the field of explosion testing.
- 15 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
High-Temperature Resistance BiScO₃–PbTiO₃ Nanofiber Overpressure Sensor for Free-Field Shock Waves Testing
In the process of developing energetic materials, it is necessary to evaluate the explosive power of energetic materials, especially the destructive effect of shock waves. Overpressure measurement is an important method to evaluate the power of shock waves. This article proposes an overpressure sensor based on BiScO3–PbTiO3 (BSPT) piezoelectric ceramic nanofibers (NFs). The BSPT NF sensor has the characteristics of high-temperature and high-pressure impact resistance and can be used for shock wave measurement. Experimental results show that the BSPT NF sensor has high-temperature stability; the sensitivity remains above 5.4 V/N at 60 °C–220 °C, and its sensitivity is still higher than 3.7 V/N at 240 °C. In addition, the BSPT NFs overpressure sensor has excellent overload resistance, measuring up to 65 kPa of overpressure without any damage when the trinitrotoluene (TNT) equivalent is 9.6 kg and the sensor is 4 m away from the explosion center. The results indicate that the BSPT NFs overpressure sensor has great application potential in the field of explosion testing.
- 7 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
All Solid-State Electrode With Low Contact Resistance and Low Polarization for Measuring the Electrical Properties of Rocks
Accurate measurement of rock electrical properties plays a crucial role in resource exploration and geological exploration. But there are kinds of problems with traditional rock measuring electrodes including high contact resistance, high electrode polarization, low stability and so on. To solve these problems, we designed and fabricated an all solid-state electrode with low contact resistance, low polarizability and high stability. The electrode consists of silver (Ag) and silver chloride (AgCl). To reduce the contact resistance between the electrode and rocks, the electrode was fabricated by powder sintering and repressing, and a scanning electron microscope (SEM) showed that the surface of the electrodes was multi-holes and coarse which is beneficial to reduce contact resistance. In addition, the Ag and AgCl mixture was prepared in the polyvinyl pyrrolidone (PVP) gel, which reduced the particle size of the AgCl and led to a low polarization degree of the electrode. An experimental system for evaluation and characterization was designed to measure the basic characteristics, stability, contact resistance and polarization of the electrodes, which are essential features and will affect the accuracy of electrical measurement. And the copper (Cu) electrode is the reference electrode. The results showed that the maximum resistance of the electrode pair is lower than 0.13 Ω. Through the measurements of core samples with different moisture content, contact resistances are lower than the Cu electrodes by at least 74%, and the accuracy of resistivity measurement is increased by more than 25%. The polarization degree of the electrode is reduced by more than 65%. After multiple measurements, the electrodes still maintain great performance and the uncertainty in measurement keeps at a low level. These characteristics will improve the measuring accuracy of the core electrical properties remarkably. Therefore, this research will promote the study of petrophysical and the exploration of mineral resources.
- 7 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
All Solid-State Electrode With Low Contact Resistance and Low Polarization for Measuring the Electrical Properties of Rocks
Accurate measurement of rock electrical properties plays a crucial role in resource exploration and geological exploration. But there are kinds of problems with traditional rock measuring electrodes including high contact resistance, high electrode polarization, low stability and so on. To solve these problems, we designed and fabricated an all solid-state electrode with low contact resistance, low polarizability and high stability. The electrode consists of silver (Ag) and silver chloride (AgCl). To reduce the contact resistance between the electrode and rocks, the electrode was fabricated by powder sintering and repressing, and a scanning electron microscope (SEM) showed that the surface of the electrodes was multi-holes and coarse which is beneficial to reduce contact resistance. In addition, the Ag and AgCl mixture was prepared in the polyvinyl pyrrolidone (PVP) gel, which reduced the particle size of the AgCl and led to a low polarization degree of the electrode. An experimental system for evaluation and characterization was designed to measure the basic characteristics, stability, contact resistance and polarization of the electrodes, which are essential features and will affect the accuracy of electrical measurement. And the copper (Cu) electrode is the reference electrode. The results showed that the maximum resistance of the electrode pair is lower than 0.13 Ω. Through the measurements of core samples with different moisture content, contact resistances are lower than the Cu electrodes by at least 74%, and the accuracy of resistivity measurement is increased by more than 25%. The polarization degree of the electrode is reduced by more than 65%. After multiple measurements, the electrodes still maintain great performance and the uncertainty in measurement keeps at a low level. These characteristics will improve the measuring accuracy of the core electrical properties remarkably. Therefore, this research will promote the study of petrophysical and the exploration of mineral resources.