Decao Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Decao Wu has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Binbin Luo
Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing, China
8 shared publications Hong Gu
Chongqing Univ Technol, Chongqing Key Lab Opt Fiber Sensor & Photoelect, Chongqing 400054, Peoples R China
2 shared publicationsMingfu Zhao
Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing, China
2 shared publicationsShenghui Shi
Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing, China
2 shared publicationsShengyou Huang
Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing, China
2 shared publicationsXiangwen Yang
Chongqing Univ Technol, Chongqing Key Lab Opt Fiber Sensor & Photoelect, Chongqing 400054, Peoples R China
2 shared publications
Latest Publications
- 31 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
Thin-Core Fiber MZI-Based Flexible Tactile Sensors Enable Multi-Perception in Wearables and Robots
Tactile sensors are functional devices that emulate the ability of human skin to perceive external stimuli and play a critical role in healthcare, industrial manufacturing, and virtual reality. In this study, a flexible tactile sensor based on an optical fiber Mach-Zehnder interferometer (MZI) with multifunctional sensing capability is proposed. The sensor adopts an MZI structure encapsulated by polydimethylsiloxane (PDMS) films, in which the MZI is formed by splicing a thin-core fiber (TCF) between two multimode fibers (MMFs). Owing to the high sensitivity of the MZI structure to external stimuli, applied mechanical inputs are converted into variations in optical interference intensity. The proposed sensor exhibits a sensitivity of 1.27 dB/N within a pressure range of 0 to 10 N, along with excellent dynamic response over a frequency range from 0.1 to 200 Hz, a fast response time of 50 ms, and good repeatability and stability. As a proof of concept, the sensor demonstrates the ability to identify object properties such as hardness, texture, and shape. In addition, it enables physiological pulse signal monitoring and can be applied to synchronous and intelligent gesture control of robotic hand. The tactile sensor developed in this work features high sensitivity, a wide measurement range, simple fabrication, and immunity to electromagnetic interference, indicating broad application potential in wearable devices and human-machine interaction (HMI).
- 31 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
Thin-Core Fiber MZI-Based Flexible Tactile Sensors Enable Multi-Perception in Wearables and Robots
Tactile sensors are functional devices that emulate the ability of human skin to perceive external stimuli and play a critical role in healthcare, industrial manufacturing, and virtual reality. In this study, a flexible tactile sensor based on an optical fiber Mach-Zehnder interferometer (MZI) with multifunctional sensing capability is proposed. The sensor adopts an MZI structure encapsulated by polydimethylsiloxane (PDMS) films, in which the MZI is formed by splicing a thin-core fiber (TCF) between two multimode fibers (MMFs). Owing to the high sensitivity of the MZI structure to external stimuli, applied mechanical inputs are converted into variations in optical interference intensity. The proposed sensor exhibits a sensitivity of 1.27 dB/N within a pressure range of 0 to 10 N, along with excellent dynamic response over a frequency range from 0.1 to 200 Hz, a fast response time of 50 ms, and good repeatability and stability. As a proof of concept, the sensor demonstrates the ability to identify object properties such as hardness, texture, and shape. In addition, it enables physiological pulse signal monitoring and can be applied to synchronous and intelligent gesture control of robotic hand. The tactile sensor developed in this work features high sensitivity, a wide measurement range, simple fabrication, and immunity to electromagnetic interference, indicating broad application potential in wearable devices and human-machine interaction (HMI).
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Probe-Type QEPAS Gas Sensor Based on Graded-Index Fiber Collimator
The quartz-enhanced photoacoustic spectroscopy (QEPAS) gas sensor exhibited high sensitivity and excellent gas selectivity without requiring a long optical path cell, offering cost-effectiveness and ease of miniaturization compared to tunable diode laser absorption spectroscopy (TDLAS) and cavity enhance absorption spectroscopy (CEAS) technologies. However, its volume was constrained by the dimensions of the laser collimator and the multi-reflection optical path, limiting further size reduction. This study employed a fusion splice method to combine single-mode fiber, coreless fiber, and graded-index fiber, developing a graded-index fiber collimator specifically tailored for QEPAS. The collimator featured a diameter of only 125 μm while achieving an effective collimation distance exceeding 20 mm. This allowed mechanical integration into the acoustic micro-resonator (MR) using a multi-tube nested coupling method, forming a probe-type structure with dual-MR parallel off-axis alignment and compact dimensions of 16 mm × 3.5 mm. This design significantly reduced the sensor volume while maintaining high sensitivity. Experimental results showed that, using water vapor as the target gas with a laser light source at a wavelength of 1392.53 nm and an average optical power of 10 mW, the amplitude of the second harmonic photoacoustic signal generated by this probe was nearly 26 times higher than that of the bare tuning fork off-axis structure and 1.72 times higher than the conventional gradient-index lens collimation single-MR off-axis structure. The probe’s minimum detectable limit for water vapor reached 0.73 ppm. Its compact design enhances adaptability to various measurement scenarios, offering considerable application value.
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Probe-Type QEPAS Gas Sensor Based on Graded-Index Fiber Collimator
The quartz-enhanced photoacoustic spectroscopy (QEPAS) gas sensor exhibited high sensitivity and excellent gas selectivity without requiring a long optical path cell, offering cost-effectiveness and ease of miniaturization compared to tunable diode laser absorption spectroscopy (TDLAS) and cavity enhance absorption spectroscopy (CEAS) technologies. However, its volume was constrained by the dimensions of the laser collimator and the multi-reflection optical path, limiting further size reduction. This study employed a fusion splice method to combine single-mode fiber, coreless fiber, and graded-index fiber, developing a graded-index fiber collimator specifically tailored for QEPAS. The collimator featured a diameter of only 125 μm while achieving an effective collimation distance exceeding 20 mm. This allowed mechanical integration into the acoustic micro-resonator (MR) using a multi-tube nested coupling method, forming a probe-type structure with dual-MR parallel off-axis alignment and compact dimensions of 16 mm × 3.5 mm. This design significantly reduced the sensor volume while maintaining high sensitivity. Experimental results showed that, using water vapor as the target gas with a laser light source at a wavelength of 1392.53 nm and an average optical power of 10 mW, the amplitude of the second harmonic photoacoustic signal generated by this probe was nearly 26 times higher than that of the bare tuning fork off-axis structure and 1.72 times higher than the conventional gradient-index lens collimation single-MR off-axis structure. The probe’s minimum detectable limit for water vapor reached 0.73 ppm. Its compact design enhances adaptability to various measurement scenarios, offering considerable application value.
- 7 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (10) , 17144-17152
Plastic Optical Fiber With Spherical Lens Embedded in Mattress for Sleep Monitoring
The quality of sleep is closely related to human health; however, traditional polysomnography is expensive and time-consuming, making it impractical for routine home sleep diagnosis. This study introduces a smart mattress based on a spherical lens enhanced plastic optical fiber sensor. UV-fused silica ball lenses are embedded into PMMA plastic optical fibers, which are then encapsulated with Ecoflex silicone rubber. The smart mattress employs a dual-channel design and collected data from eight subjects in various sleep postures. The signals are transformed into the frequency domain for processing using the Welch power spectral density estimation method. The results indicate that the smart mattress has a mean absolute error of less than 1.92 bpm for heart rate (HR) and 0.95 bpm for respiratory rate (RR). Additionally, consistency analysis was conducted using Bland-Altman analysis and linear regression methods. The results showed that the 95% limits of agreement for HR were -3.047 bpm to 2.915 bpm, with an R² value of 0.95729, and for RR they were -1.741 bpm to 1.380 bpm, with an R² value of 0.9738. Furthermore, Random Forest algorithm was applied to the dataset, successfully classifying between five different sleep behaviors with a classification accuracy of 97.67%. This smart mattress is capable of long-term, stable monitoring of physiological parameters and sleep behavior monitoring, providing a low-cost solution for home sleep monitoring.
- 7 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (10) , 17144-17152
Plastic Optical Fiber With Spherical Lens Embedded in Mattress for Sleep Monitoring
The quality of sleep is closely related to human health; however, traditional polysomnography is expensive and time-consuming, making it impractical for routine home sleep diagnosis. This study introduces a smart mattress based on a spherical lens enhanced plastic optical fiber sensor. UV-fused silica ball lenses are embedded into PMMA plastic optical fibers, which are then encapsulated with Ecoflex silicone rubber. The smart mattress employs a dual-channel design and collected data from eight subjects in various sleep postures. The signals are transformed into the frequency domain for processing using the Welch power spectral density estimation method. The results indicate that the smart mattress has a mean absolute error of less than 1.92 bpm for heart rate (HR) and 0.95 bpm for respiratory rate (RR). Additionally, consistency analysis was conducted using Bland-Altman analysis and linear regression methods. The results showed that the 95% limits of agreement for HR were -3.047 bpm to 2.915 bpm, with an R² value of 0.95729, and for RR they were -1.741 bpm to 1.380 bpm, with an R² value of 0.9738. Furthermore, Random Forest algorithm was applied to the dataset, successfully classifying between five different sleep behaviors with a classification accuracy of 97.67%. This smart mattress is capable of long-term, stable monitoring of physiological parameters and sleep behavior monitoring, providing a low-cost solution for home sleep monitoring.
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (23) , 39050-39058
Design and Gesture Recognition of Wrist Joint Posture Sensor Based on Fiber Bragg Gratings
The wrist joint is the main part of hand movement control, and its posture detection is very important for gesture recognition. This study presents a novel and straightforward method for detecting wrist joint posture utilizing Fiber Bragg Grating (FBG) sensors. FBGs integrated with a composite substrate of Polydimethylsiloxane (PDMS) and Polyimide (PI) were affixed to the skin surface of specific forearm muscles to monitor forearm muscle deformation induced by wrist joint movement. The response characteristics and applicability of the designed sensor were validated through simulation and testing. A Long Short-Term Memory (LSTM) algorithm with an attention mechanism was employed for training and predicting eight static gestures from testers with varying physiques. Experimental results demonstrated that, in comparison to other substrates, FBG with PDMS and PI composite substrates exhibited superior anti-creep properties, fast response and recovery times (198ms/202ms), high sensitivity (7.09pm/°), and good repeatability (Standard deviation of 2.48%). The LSTM model could effectively predict the eight static gestures of the testers, with 99.48% recognition accuracy for a same person and 96.67% recognition accuracy for 10 different persons. The proposed sensors would have potential application in field of the rehabilitation training, virtual reality (VR) or augmented reality (AR), human-computer interaction etc.
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (23) , 39050-39058
Design and Gesture Recognition of Wrist Joint Posture Sensor Based on Fiber Bragg Gratings
The wrist joint is the main part of hand movement control, and its posture detection is very important for gesture recognition. This study presents a novel and straightforward method for detecting wrist joint posture utilizing Fiber Bragg Grating (FBG) sensors. FBGs integrated with a composite substrate of Polydimethylsiloxane (PDMS) and Polyimide (PI) were affixed to the skin surface of specific forearm muscles to monitor forearm muscle deformation induced by wrist joint movement. The response characteristics and applicability of the designed sensor were validated through simulation and testing. A Long Short-Term Memory (LSTM) algorithm with an attention mechanism was employed for training and predicting eight static gestures from testers with varying physiques. Experimental results demonstrated that, in comparison to other substrates, FBG with PDMS and PI composite substrates exhibited superior anti-creep properties, fast response and recovery times (198ms/202ms), high sensitivity (7.09pm/°), and good repeatability (Standard deviation of 2.48%). The LSTM model could effectively predict the eight static gestures of the testers, with 99.48% recognition accuracy for a same person and 96.67% recognition accuracy for 10 different persons. The proposed sensors would have potential application in field of the rehabilitation training, virtual reality (VR) or augmented reality (AR), human-computer interaction etc.
- Open Access
Study on the Design and Performance of a Glove Based on the FBG Array for Hand Posture Sensing
This study introduces a new wearable fiber-optic sensor glove. The glove utilizes a flexible material, polydimethylsiloxane (PDMS), and a silicone tube to encapsulate fiber Bragg gratings (FBGs). It is employed to enable the self-perception of hand posture, gesture recognition, and the prediction of grasping objects. The investigation employs the Support Vector Machine (SVM) approach for predicting grasping objects. The proposed fiber-optic sensor glove can concurrently monitor the motion of 14 hand joints comprising 5 metacarpophalangeal joints (MCP), 5 proximal interphalangeal joints (PIP), and 4 distal interphalangeal joints (DIP). To expand the measurement range of the sensors, a sinusoidal layout incorporates the FBG array into the glove. The experimental results indicate that the wearable sensing glove can track finger flexion within a range of 0° to 100°, with a modest minimum measurement error (Error) of 0.176° and a minimum standard deviation (SD) of 0.685°. Notably, the glove accurately detects hand gestures in real-time and even forecasts grasping actions. The fiber-optic smart glove technology proposed herein holds promising potential for industrial applications, including object grasping, 3D displays via virtual reality, and human–computer interaction.
Open AccessStudy on the Design and Performance of a Glove Based on the FBG Array for Hand Posture Sensing
This study introduces a new wearable fiber-optic sensor glove. The glove utilizes a flexible material, polydimethylsiloxane (PDMS), and a silicone tube to encapsulate fiber Bragg gratings (FBGs). It is employed to enable the self-perception of hand posture, gesture recognition, and the prediction of grasping objects. The investigation employs the Support Vector Machine (SVM) approach for predicting grasping objects. The proposed fiber-optic sensor glove can concurrently monitor the motion of 14 hand joints comprising 5 metacarpophalangeal joints (MCP), 5 proximal interphalangeal joints (PIP), and 4 distal interphalangeal joints (DIP). To expand the measurement range of the sensors, a sinusoidal layout incorporates the FBG array into the glove. The experimental results indicate that the wearable sensing glove can track finger flexion within a range of 0° to 100°, with a modest minimum measurement error (Error) of 0.176° and a minimum standard deviation (SD) of 0.685°. Notably, the glove accurately detects hand gestures in real-time and even forecasts grasping actions. The fiber-optic smart glove technology proposed herein holds promising potential for industrial applications, including object grasping, 3D displays via virtual reality, and human–computer interaction.
- 21 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (15) , 16788-16796
Research on Vector Deformation Detection Method of Fuel Rods Based on FBG Array
In the operation of pressurized water reactors, the bending deformation of fuel rods caused by mechanical fatigue accumulation represents a significant safety risk. In the past, deformation detection research primarily focused on spent fuel rods, the detection process was cumbersome, and the measurement data lacked reference value for the optimal design of the reactor. To address this issue, a real-time monitoring method for vector deformation of fuel rods using optical fiber sensing technology was investigated in this study. This method can withstand high temperature, high pressure and complicated electromagnetic environment associated with reactor thermal simulation experimental devices. In this method, 4×3 FBG arrays are packaged in micro-groove on the surface of the fuel rod in order to measure the stress-strain at various locations along the rod. Based on the principle of cross-sectional strain symmetry, temperature is separated from FBG wavelength drift signal, and achieved temperature compensation for strain measurement. A CNN model is established to solve the vector deformation parameters of the rod, including bending position, direction and deflection. The curvature distribution of the rod is calculated using the three-point interpolation method, which enables the 3D reconstruction of the rod morphology. Experiments show that the proposed method can accurately detect the deformation parameters in a variable-temperature environment, and the bending reconstruction curve corresponds well with the mechanical simulation, meeting the accuracy requirements of the reactor thermal experiment.
- 21 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (15) , 16788-16796
Research on Vector Deformation Detection Method of Fuel Rods Based on FBG Array
In the operation of pressurized water reactors, the bending deformation of fuel rods caused by mechanical fatigue accumulation represents a significant safety risk. In the past, deformation detection research primarily focused on spent fuel rods, the detection process was cumbersome, and the measurement data lacked reference value for the optimal design of the reactor. To address this issue, a real-time monitoring method for vector deformation of fuel rods using optical fiber sensing technology was investigated in this study. This method can withstand high temperature, high pressure and complicated electromagnetic environment associated with reactor thermal simulation experimental devices. In this method, 4×3 FBG arrays are packaged in micro-groove on the surface of the fuel rod in order to measure the stress-strain at various locations along the rod. Based on the principle of cross-sectional strain symmetry, temperature is separated from FBG wavelength drift signal, and achieved temperature compensation for strain measurement. A CNN model is established to solve the vector deformation parameters of the rod, including bending position, direction and deflection. The curvature distribution of the rod is calculated using the three-point interpolation method, which enables the 3D reconstruction of the rod morphology. Experiments show that the proposed method can accurately detect the deformation parameters in a variable-temperature environment, and the bending reconstruction curve corresponds well with the mechanical simulation, meeting the accuracy requirements of the reactor thermal experiment.
- 17 October 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (22) , 40251-40264
Highly sensitive curvature sensor based on a sandwich multimode fiber Mach–Zehnder interferometer
A highly sensitive optical fiber Mach–Zehnder interference curvature sensor based on MMF-GIMMF-MMF, which was made by sandwiching the graded-index multimode fiber (GIMMF) between two pieces of very short stepped-index multimode fibers (SIMMFs) spliced with input-single-mode fiber (SMF) and output–SMF, respectively, was proposed. The core diameter of the SIMMFs and GIMMF was 105 µm and 50 µm, respectively, and cladding diameter of them were both 125 µm. The sensing principle of the MMF-GIMMF- MMF sensors and the influences of structure parameters on the interference spectrum characteristics were theoretically analyzed in detail. Experimental results showed that when the length of the GIMMF was short enough (usually ≤ 10 mm), interference spectrum was induced by the interaction between the core modes and the low-order cladding modes due to the special structure of the designed Mach–Zehnder interferometer. Intensity of the interference valleys was highly sensitive to the applied bending but nearly independent of the surrounding temperature, on the contrary, the dip wavelength showed negligible sensitivity to the applied bending but relatively high temperature sensitivity. Thus, a temperature- independent curvature sensor could be realized by tracing the intensity variation of interference valley. In addition, different interference valley exhibited different intensity-based curvature sensitivity, providing more options for curvature sensing applications. Especially, total length of the sensor could be as short as 3 mm with length of GIMMF and SIMMFs only 1mm, the maximum curvature sensitivity could reach up to -78.75 dB/m-1 in the small curvature range of 0-2.36 m-1. Owing to its compact size, easy fabrication, good reproducibility and low cost, the proposed sensor is promising for bending-related high-precision engineering applications.
- 17 October 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (22) , 40251-40264
Highly sensitive curvature sensor based on a sandwich multimode fiber Mach–Zehnder interferometer
A highly sensitive optical fiber Mach–Zehnder interference curvature sensor based on MMF-GIMMF-MMF, which was made by sandwiching the graded-index multimode fiber (GIMMF) between two pieces of very short stepped-index multimode fibers (SIMMFs) spliced with input-single-mode fiber (SMF) and output–SMF, respectively, was proposed. The core diameter of the SIMMFs and GIMMF was 105 µm and 50 µm, respectively, and cladding diameter of them were both 125 µm. The sensing principle of the MMF-GIMMF- MMF sensors and the influences of structure parameters on the interference spectrum characteristics were theoretically analyzed in detail. Experimental results showed that when the length of the GIMMF was short enough (usually ≤ 10 mm), interference spectrum was induced by the interaction between the core modes and the low-order cladding modes due to the special structure of the designed Mach–Zehnder interferometer. Intensity of the interference valleys was highly sensitive to the applied bending but nearly independent of the surrounding temperature, on the contrary, the dip wavelength showed negligible sensitivity to the applied bending but relatively high temperature sensitivity. Thus, a temperature- independent curvature sensor could be realized by tracing the intensity variation of interference valley. In addition, different interference valley exhibited different intensity-based curvature sensitivity, providing more options for curvature sensing applications. Especially, total length of the sensor could be as short as 3 mm with length of GIMMF and SIMMFs only 1mm, the maximum curvature sensitivity could reach up to -78.75 dB/m-1 in the small curvature range of 0-2.36 m-1. Owing to its compact size, easy fabrication, good reproducibility and low cost, the proposed sensor is promising for bending-related high-precision engineering applications.
- 21 June 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (19) , 5552-5558
Cladding mode characteristics simulation of an excessively tilted fiber grating coated with gold nanoshells
The cladding mode characteristics simulation of an excessively tilted fiber grating (ExTFG) coated with gold nanoshells was conducted in this study. First, the effective refractive indices of the core and cladding mode before coating were obtained by solving the eigenvalue equation of the three-layer waveguide structure, and the coupling characteristics were briefly analyzed. Then H E 1 , m and E H 1 , m modes were selected as the research objects, and the spectral characteristics of ExTFG coated with gold nanoshells were simulated by the finite element method. The simulated refractive index sensitivity of H E 1 , 29 and E H 1 , 29 modes is 160.16 and 185.03 nm/RIU, respectively. Compared with the non-localized surface plasmon resonance (LSPR) effect, it increased by 10.76 nm/RIU (7.2%) and 19.53 nm/RIU (11.8%), respectively. Thus, the LSPR effect was verified to be beneficial to improve the refractive index sensitivity of ExTFG.
- 21 June 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (19) , 5552-5558
Cladding mode characteristics simulation of an excessively tilted fiber grating coated with gold nanoshells
The cladding mode characteristics simulation of an excessively tilted fiber grating (ExTFG) coated with gold nanoshells was conducted in this study. First, the effective refractive indices of the core and cladding mode before coating were obtained by solving the eigenvalue equation of the three-layer waveguide structure, and the coupling characteristics were briefly analyzed. Then H E 1 , m and E H 1 , m modes were selected as the research objects, and the spectral characteristics of ExTFG coated with gold nanoshells were simulated by the finite element method. The simulated refractive index sensitivity of H E 1 , 29 and E H 1 , 29 modes is 160.16 and 185.03 nm/RIU, respectively. Compared with the non-localized surface plasmon resonance (LSPR) effect, it increased by 10.76 nm/RIU (7.2%) and 19.53 nm/RIU (11.8%), respectively. Thus, the LSPR effect was verified to be beneficial to improve the refractive index sensitivity of ExTFG.