LSLe Van Thanh Son

Le Van Thanh Son

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Le Van Thanh Son has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simultaneous electrochemical determination of acetaminophen and ciprofloxacin in pharmaceutical formulations using a holmium-modified UiO-66 metal-organic framework electrode

    by Nguyen Quang Man, Pham Thi Huyen Thoa, Phan Tu Quy, Truong Thi Phuong Nga, Cao Van Hoang, Le Van Thanh Son, Le Thi Hong Phong, Pham Khac Lieu, Le Lam Son, Dinh Quang Khieu

    Background and purpose: The simultaneous determination of acetaminophen (ACE) and ciprofloxacin (CIP) is of considerable importance for pharmaceutical quality control, necessitating the development of sensitive and reliable electrochemical sensors. In this study, a holmium-modified UiO-66 metal-organic framework (Ho/UiO-66) was synthesized and evaluated as an electrode modifier for the simultaneous electrochemical determination of ACE and CIP. Experimental approach: Ho/UiO-66 was synthesized via a solvothermal method and characterized by X-ray diffraction, Fourier-transform infrared spectroscopy, Raman spectroscopy, nitrogen adsorption-desorption analysis, scanning electron microscopy, transmission electron microscopy and energy-dispersive X-ray mapping. The electrochemical behaviour of ACE and CIP at the Ho/UiO-66-modified glassy carbon electrode (Ho/UiO-66/GCE) was investigated using cyclic voltammetry and differential pulse vol­tam­metry. The effects of solution pH, scan rate, accumulation potential, and accumulation time were syste­matically optimized. Key results: The characterization results demonstrated the successful incorporation of Ho species while preserving the crystalline structure of UiO-66. Among the investigated materials, Ho/UiO-66 (3/100 molar ratio) exhibited the most favourable combination of crystallinity, porosity and electrochemical performance, and was therefore selected for sensor fabrication. Under the optimized conditions, well-resolved oxidation peaks for ACE and CIP were obtained, enabling their simultaneous determination without mutual interference. The oxidation processes were found to be predominantly diffusion-controlled. The developed sensor exhibited satisfactory analytical performance with wide linear concentration ranges, low detection limits, satisfactory repeatability, reproducibility, and long-term stability. The sensor was applied to the determination of ACE and CIP in real pharmaceutical samples with satisfactory recoveries. The analytical results showed good agreement with those obtained using the reference high-performance liquid chromatography method. Conclusion: The proposed Ho/UiO-66/GCE sensor provides a reliable and practical platform for the simultaneous electro­chemical determination of ACE and CIP, demonstrating its potential applicability for pharmaceutical analysis.

  • Open Access

    Electrochemical sensing of sildenafil in pharmaceutical formulations using an (S,N)-doped reduced graphene oxide-modified electrode

    by Nguyen Quang Man, Ngo Thi Thanh Xuan, Vo Thi Khanh Ly, Le Van Thanh Son, Le Duc Anh, Le Thi Hong Phong, Nguyen Hai Phong, Pham Khac Lieu, Le Lam Son, Dinh Quang Khieu

    In this work, (S,N)-co-doped reduced graphene oxide ((S,N)-rGO) was successfully synthesized via thermal treatment and thoroughly characterized by X-ray diffraction, high-resolution transmission electron microscopy, elemental mapping, photoluminescence, and Raman spectroscopy, confirming the successful incorporation of nitrogen and sulfur into the graphene framework. The obtained (S,N)-rGO was used to modify a glassy carbon electrode for the electrochemical determination of sildenafil (SDN). The modified electrode exhibited enhanced electrocatalytic activity toward SDN oxidation, providing a well-defined current response. Under optimized conditions, the sensor showed a good linear relationship between peak current and SDN concentration in the range of 0.25–4.98 µM, with a low limit of detection of 0.24 µM and a limit of quantification of 0.78 µM. The proposed sensor demonstrated satisfactory repeatability, reproducibility, and stability, as well as good selectivity in the presence of potential interfering substances. The applicability of the method was validated by the determination of SDN in pharmaceutical samples. The results were in good agreement with those from high-performance liquid chromatography, indicating that the proposed electrochemical method is reliable and suitable for practical analysis.

  • Open Access

    Sm/UiO-66 Modified Electrode for the Electrochemical Determination of Ethambutol Hydrochloride in Pharmaceutical Formulations and Human Urine

    by Pham Thi Huyen Thoa, Nguyen Quang Man, Phan Tu Quy, Nguyen Chi Bao, Le Van Thanh Son, Le Lam Son, Dao Ngoc Nhiem, Dinh Quang Khieu

    And used as an electrode modifier for detecting ethambutol hydrochloride. The material was characterized by X-ray diffraction, Fourier-transform infrared spectroscopy, electro­chemical impedance spectroscopy, energy-dispersive X-ray mapping, X-ray photoelectron spectroscopy and scanning electron microscopy. The electrochemical behaviour of etham­butol at the Sm/UiO-66 modified glassy carbon electrode was examined using cyclic voltam­metry and differential pulse voltammetry. The Sm/UiO-66-modified electrode exhibited a strong electrocatalytic response toward ethambutol oxidation, with a clearly defined anodic peak current. Under optimized conditions, the sensor showed a linear response in the 0.5 to 9.9 µM concentration range with a detection limit of 0.23 µM. The sensor demonstrated excellent repeatability (RSD < 3.5 %, n = 10), stability over one week, and high selectivity against common interfering substances. Notably, the proposed method was successfully applied to determine ethambutol in three pharmaceutical and three human urine samples, with exceptional recoveries. The proposed Sm/UiO-66 modified electrode is a reliable, sensitive, and selective tool for ethambutol analysis. This method can serve as a practical alternative or complementary approach for routine pharmaceutical quality control and therapeutic monitoring in tuberculosis treatment.

  • Open Access

    MIL-101 (Cr): Synthesis and simultaneous electrochemical determination of uric acid and theophylline using MIL-101 (Cr) modified electrode

    by Nguyen Ngoc Nghia, Nguyen Quang Man, Hoa Thi Le, Nguyen Duc Vu Quyen, Ho Van Minh Hai, Nguyen Chi Bao, Son Van Thanh Le, Trinh Ngoc Dat, Le Thi Hong Phong, Vo Thi Khanh Ly, et al.

    This paper presents the synthesis of metal-organic frameworks in the MIL (Materials Institute Lavoisier) series using a hydrothermal process. Our research revealed that MIL-101 was formed at the early synthetic stage, approximately eight hours, followed by the formation of MIL-88B with further prolongation of the hydrothermal time. The morphology of the octahedral shape for MIL-101 transformed into the rode-like shape of MIL-88B, accompanied by a decrease in the surface area. The electrode modified by MIL-101 exhibited electrochemical activity towards uric acid and theophylline better than that modified by MIL-88B. We also developed a glassy carbon electrode (GCE) modified by MIL-101 for simultaneous uric acid and theophylline detection. Electrochemical sensing features were investigated using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and differential pulse voltammetry (DPV). The calibration curves for uric acid and theophylline were obtained in the 0.20–1.69 µM range. The detection limits (3σ) were 0.12 µM and 0.13 µM for uric acid and theophylline, respectively. Notably, using a standard addition method, the present approach was used to determine URI and THE in urine samples, achieving exceptional recoveries. The proposed electrochemical sensor also revealed good reproducibility, repeatability, and long-term stability.


  • Open Access

    Simultaneous electrochemical determination of uric acid and hypoxanthine at a TiO2/graphene quantum dot-modified electrode

    by Vu Ngoc Hoang, Dang Thi Ngoc Hoa, Nguyen Quang Man, Le Van Thanh Son, Vo Thang Nguyen, Le Thi Hong Phong, Ly Hoang Diem, Kieu Chan Ly, Ho Sy Thang, Dinh Quang Khieu

    A TiO2/graphene quantum dots composite (TiO2/GQDs) obtained by in situ synthesis of GQDs, derived from coffee grounds, and peroxo titanium complexes was used as electrode modifier in the simultaneous electrochemical determination of uric acid and hypoxanthine. The TiO2/GQDs material was characterized by photoluminescence, X-ray diffraction, Raman spectroscopy, high-resolution transmission electron microscopy, and energy-dispersive X-ray mapping. The TiO2/GQDs-GCE exhibits better electrochemical activity for uric acid and hypoxanthine than GQDs/GCE or TiO2/GCE in differential pulse voltammetry (DPV) measurements. Under optimized conditions, the calibration plots were linear in the range from 1.00 to 15.26 μM for both uric acid and hypoxanthine. The limits of detection of this method were 0.58 and 0.68 μM for uric acid and hypoxanthine, respectively. The proposed DPV method was employed to determine uric acid and hypoxanthine in urine samples with acceptable recovery rates.


  • Open Access

    Photocatalytic degradation of methylene blue under visible light by cobalt ferrite nanoparticles/graphene quantum dots

    by Vo Chau Ngoc Anh, Le Thi Thanh Nhi, Le Thi Kim Dung, Dang Thi Ngoc Hoa, Nguyen Truong Son, Nguyen Thi Thao Uyen, Nguyen Ngoc Uyen Thu, Le Van Thanh Son, Le Trung Hieu, Tran Ngoc Tuyen, et al.

    A simple approach was developed to synthesize cobalt ferrite nanoparticles/graphene quantum dots (CF/GQDs). The material was prepared from a homogeneous mixture of iron nitrate, cobalt nitrate, and starch at 140, 180 and 200 °C in a 24 h thermal hydrolysis process. The obtained materials were characterised by using X-ray diffraction, scanning electron microscopy, transmission electron microscopy, ultraviolet–visible diffuse reflectance spectroscopy, Fourier-transform infrared spectroscopy, photoluminescence spectroscopy, vibrating-sample magnetometry, and nitrogen adsorption/desorption isotherms. Cobalt ferrite crystals of around 8–10 nm and graphene quantum dots formed directly at 200 °C. Stacking GQDs sheets onto the CF nanoparticles resulted in CF/GQDs nanoparticles. The nanocomposite exhibits satisfactory fluorescent and superparamagnetic properties, which are vital for catalytic applications. The CF/GQDs catalyse significantly the degradation of methylene blue (MB) under visible light. The catalyst can be recycled with an external magnetic field and displays suitable stability. Also, it was reused in three successive experiments with a loss of efficiency of about 5%. The CF/GQDs are considered as an efficient photocatalyst for MB degradation and other dyes.


  • Open Access

    Hydrothermal synthesis of carbon nanodots from wine cork and biocompatible fluorescent probe

    by Ngo Khoa Quang, Nguyen Ngoc Hieu, Vo Van Quoc Bao, Vo Thi Phuoc, Le Xuan Diem Ngoc, Luong Quang, Nguyen Minh Tri, Le Van Thanh Son, Che Thi Cam Ha

    We presented a low-cost and simple method to synthesize carbon nanodots (CDs) from waste wine cork using hydrothermal synthesis. The structural and optical properties of the CDs are characterized by TEM, FTIR, Raman, UV-Vis absorption, and photoluminescence (PL) spectra. The analysis results indicated the average diameter of CDs ⁓ 6.2 ± 2.7 nm. Optical measurements showed the phenomenon of excitation-dependent PL and the formation of functional groups on the surface of the particles. CDs with a quantum yield of 1.54% was calculated using quinine sulfate as reference. Furthermore, a probe of wine cork-derived CDs in bioimaging has been successfully applied in living mesenchymal stem cells (MSCs). After treatment with CDs, MSCs exhibited fluorescence including green, yellow, and red colors under the excitation wavelengths in the range 330–385 nm, 450–480 nm, and 510–550 nm, respectively. The achievement demonstrated potential applications of fluorescent CDs in the field of the fluorescent image.