Beryl Schwarz-Herzke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Beryl Schwarz-Herzke has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Dieter Drescher
Department of Orthodontics, University of Homburg, Saar, Germany
3 shared publications - Kathrin Becker
Department of Orthodontics and Dentofacial Orthopaedics Charité – Universitätsmedizin Berlin Berlin Germany
3 shared publications - Giulia Brunello
Department of Oral Surgery University Hospital of Düsseldorf Düsseldorf Germany
2 shared publications - Annika Pliska
Department of Orthodontics, University Hospital of Düsseldorf, 40225 Düsseldorf, Germany
1 shared publication - Benedict Wilmes
Department of Orthodontics, University of Düsseldorf, Düsseldorf, Germany.
1 shared publication Ivonne Jeanette Knorr
Central Unit for Animal Research and Scientific Animal Welfare Affairs University of Düsseldorf Düsseldorf Germany
1 shared publication
Latest Publications
- Open Access
- 4 March 2025
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 87 (3) , 269-278
Is simultaneous placement of orthodontic mini-implants and skeletally anchored appliances advisable?
Purpose: For the fabrication of an orthodontic mini-implant (OMI)-borne appliance, the position of the inserted OMI can be detected by a silicone impression or an intraoral scan (IOS). In case of digital planning, it can be taken over from the planning and the appliance can be produced in advance. This study aimed to evaluate the accuracy of these three techniques and whether there is an association with the insertion angle. Methods: Two OMIs were digitally planned and placed in the anterior palate of 11 human cadavers with different insertion angles. Subsequently, the position of each OMI was detected by an IOS, a silicone impression, and a cone-beam computed tomography (CBCT) scan, whereby the CBCT scan was set as “real position”. The measurements of accuracy were performed between the CBCT data as a reference and the preoperative digital planning, the IOS and the plaster model manufactured from the silicone impression. Results: The IOS was the most accurate in detecting the Top (mean deviation 0.14 mm) and the Apex (mean deviation 0.36 mm) of the OMIs. Significant linear deviations between the three modalities were registered for both Top ( p < 0.001) and Apex ( p = 0.010). The digital planning procedure achieved the lowest mean angular deviation of 3.7° and was significantly more accurate in this respect than the IOS ( p < 0.001). Conclusion: All methods were subject to small, but clinically irrelevant deviations. Within the limitations of a cadaver study, all methods appear to be suitable for clinical use. However, the digital workflow could be advantageous, requiring only a single visit for OMI placement and simultaneous appliance fitting.
- 4 March 2025
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 87 (3) , 269-278
Open AccessIs simultaneous placement of orthodontic mini-implants and skeletally anchored appliances advisable?
Purpose: For the fabrication of an orthodontic mini-implant (OMI)-borne appliance, the position of the inserted OMI can be detected by a silicone impression or an intraoral scan (IOS). In case of digital planning, it can be taken over from the planning and the appliance can be produced in advance. This study aimed to evaluate the accuracy of these three techniques and whether there is an association with the insertion angle. Methods: Two OMIs were digitally planned and placed in the anterior palate of 11 human cadavers with different insertion angles. Subsequently, the position of each OMI was detected by an IOS, a silicone impression, and a cone-beam computed tomography (CBCT) scan, whereby the CBCT scan was set as “real position”. The measurements of accuracy were performed between the CBCT data as a reference and the preoperative digital planning, the IOS and the plaster model manufactured from the silicone impression. Results: The IOS was the most accurate in detecting the Top (mean deviation 0.14 mm) and the Apex (mean deviation 0.36 mm) of the OMIs. Significant linear deviations between the three modalities were registered for both Top ( p < 0.001) and Apex ( p = 0.010). The digital planning procedure achieved the lowest mean angular deviation of 3.7° and was significantly more accurate in this respect than the IOS ( p < 0.001). Conclusion: All methods were subject to small, but clinically irrelevant deviations. Within the limitations of a cadaver study, all methods appear to be suitable for clinical use. However, the digital workflow could be advantageous, requiring only a single visit for OMI placement and simultaneous appliance fitting.
- Open Access
- 11 August 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (16) , 9162
Accuracy of Two Variants of 3D-Printed Insertion Guides for Orthodontic Mini-Implants: An Ex Vivo Study in Human Cadavers
Insertion guides are becoming popular for orthodontic mini-implant positioning. The aim of this study was to evaluate and compare the accuracy of two different mini-implant insertion guides, with or without pre-drilling, in a human cadaveric model. Maxillary casts of six fresh frozen specimens were digitized to create insertion guides. Sixty mini-implants were randomly inserted with full-arch or skeletonized guides, either with or without predrilling. Pre- and post-treatment CBCTs were superimposed using rigid registration. Transformation matrices of the planned and real positions were obtained, and distances at the mini-implant neck and apex, as well as the angular deviation, were calculated. The Kruskal–Wallis test was performed, followed by a post hoc test when indicated. Out of 60 inserted mini-implants, 46 could be evaluated. Of these, 10 initially assigned to no pre-drilling required this procedure due to very high bone density. Therefore, 32 implants were inserted with pre-drilling (n = 15 full-arch; n = 17 skeletonized) and 14 without (n = 7 full-arch; n = 7 skeletonized). The lowest mean deviation at the neck was 1.22 ± 0.6 mm, registered in the full-arch/pre-drilling group. The skeletonized/no pre-drilling group presented the lowest mean values at the apex, i.e., 1.72 ± 1.22 mm, as well as the lowest mean angular deviation, i.e., 8.23 ± 4.24°. Significant differences among groups were observed only at the neck, with higher mean deviation in the skeletonized/pre-drilling group than in the full-arch/pre-drilling one (p = 0.014). In conclusion, within the limitations of the study, rather high deviations between planned and real mini-implant positions were found. Further studies are needed on how to improve the accuracy within in vivo settings.
- 11 August 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (16) , 9162
Open AccessAccuracy of Two Variants of 3D-Printed Insertion Guides for Orthodontic Mini-Implants: An Ex Vivo Study in Human Cadavers
Insertion guides are becoming popular for orthodontic mini-implant positioning. The aim of this study was to evaluate and compare the accuracy of two different mini-implant insertion guides, with or without pre-drilling, in a human cadaveric model. Maxillary casts of six fresh frozen specimens were digitized to create insertion guides. Sixty mini-implants were randomly inserted with full-arch or skeletonized guides, either with or without predrilling. Pre- and post-treatment CBCTs were superimposed using rigid registration. Transformation matrices of the planned and real positions were obtained, and distances at the mini-implant neck and apex, as well as the angular deviation, were calculated. The Kruskal–Wallis test was performed, followed by a post hoc test when indicated. Out of 60 inserted mini-implants, 46 could be evaluated. Of these, 10 initially assigned to no pre-drilling required this procedure due to very high bone density. Therefore, 32 implants were inserted with pre-drilling (n = 15 full-arch; n = 17 skeletonized) and 14 without (n = 7 full-arch; n = 7 skeletonized). The lowest mean deviation at the neck was 1.22 ± 0.6 mm, registered in the full-arch/pre-drilling group. The skeletonized/no pre-drilling group presented the lowest mean values at the apex, i.e., 1.72 ± 1.22 mm, as well as the lowest mean angular deviation, i.e., 8.23 ± 4.24°. Significant differences among groups were observed only at the neck, with higher mean deviation in the skeletonized/pre-drilling group than in the full-arch/pre-drilling one (p = 0.014). In conclusion, within the limitations of the study, rather high deviations between planned and real mini-implant positions were found. Further studies are needed on how to improve the accuracy within in vivo settings.
- Open Access
- 24 November 2021
- Published by Wiley in Journal of Clinical Periodontology
- Vol. 49 (2) , 188-197
Micro‐angiogenic patterns around orthodontic implants migrating in bone: A micro‐CT study in the rat tail model
Aim: Recent studies revealed that implants can migrate in bone when subjected to continuous loading. Since this process is suspected to be accompanied by bone remodelling, which requires blood vessel formation, the present work aimed at assessing the micro‐angiogenic patterns around migrating implants.Materials and methods: In 16 rats, two customized implants were placed in a single tail vertebra and connected with contraction springs (forces: 0 N, 0.5 N, 1.0 N, 1.5 N). After 2 or 8 weeks of loading, the animals were scanned by micro‐CT before and after vasculature perfusion with a silicone rubber. Vessels were segmented by subtraction of the two micro‐CT scans. Vessel thickness (V.Th), vessel volume per total volume (VV/TV), and vascular spacing (V.Sp) were assessed in a peri‐implant volume of interest (VOI) around each implant.Results: At 2 weeks of loading, force magnitude was significantly associated with VV/TV and V.Th values (χ2 = 10.942, p < .001 and χ2 = 6.028, p = .010, respectively). No significant differences were observed after 8 weeks of loading.Conclusions: Within the limitations of an animal study, peri‐implant vessel thickness and density were associated with force magnitude in the early loading phase, whereas effects diminished after 8 weeks of loading.
- 24 November 2021
- Published by Wiley in Journal of Clinical Periodontology
- Vol. 49 (2) , 188-197
Open AccessMicro‐angiogenic patterns around orthodontic implants migrating in bone: A micro‐CT study in the rat tail model
Aim: Recent studies revealed that implants can migrate in bone when subjected to continuous loading. Since this process is suspected to be accompanied by bone remodelling, which requires blood vessel formation, the present work aimed at assessing the micro‐angiogenic patterns around migrating implants.Materials and methods: In 16 rats, two customized implants were placed in a single tail vertebra and connected with contraction springs (forces: 0 N, 0.5 N, 1.0 N, 1.5 N). After 2 or 8 weeks of loading, the animals were scanned by micro‐CT before and after vasculature perfusion with a silicone rubber. Vessels were segmented by subtraction of the two micro‐CT scans. Vessel thickness (V.Th), vessel volume per total volume (VV/TV), and vascular spacing (V.Sp) were assessed in a peri‐implant volume of interest (VOI) around each implant.Results: At 2 weeks of loading, force magnitude was significantly associated with VV/TV and V.Th values (χ2 = 10.942, p < .001 and χ2 = 6.028, p = .010, respectively). No significant differences were observed after 8 weeks of loading.Conclusions: Within the limitations of an animal study, peri‐implant vessel thickness and density were associated with force magnitude in the early loading phase, whereas effects diminished after 8 weeks of loading.