Alan Seth Barnett
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alan Seth Barnett has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Adam W. Anderson
Vanderbilt University
1 shared publication - Baxter P. Rogers
Department of Psychiatry and Behavioral Sciences, Vanderbilt University Medical Center, Nashville, USA
1 shared publication Baxter Rogers
Department of Radiology and Radiological Sciences Vanderbilt University Medical Center Nashville TN USA
1 shared publication- Bennett A. Landman
Department of Electrical and Computer Engineering Vanderbilt University Nashville Tennessee USA
1 shared publication Bennett Landman
Department of Electrical Engineering and Computer Science Vanderbilt University Nashville TN USA
1 shared publicationCarlo Pierpaoli
Quantitative Medical Imaging Section National Institute of Biomedical Imaging and Bioengineering National Institutes of Health Bethesda MD USA
1 shared publication
Latest Publications
- Open Access
- 4 August 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (6) , 3259-3273
Mapping gradient nonlinearity and miscalibration using diffusion‐weighted MR images of a uniform isotropic phantom
Purpose: To use diffusion measurements to map the spatial dependence of the magnetic field produced by the gradient coils of an MRI scanner with sufficient accuracy to correct errors in quantitative diffusion MRI (DMRI) caused by gradient nonlinearity and gradient amplifier miscalibration.Theory and Methods: The field produced by the gradient coils is expanded in regular solid harmonics. The expansion coefficients are found by fitting a model to a minimum set of diffusion‐weighted images of an isotropic diffusion phantom. The accuracy of the resulting gradient coil field maps is evaluated by using them to compute corrected b‐matrices that are then used to process a multi‐shell diffusion tensor imaging (DTI) dataset with 32 diffusion directions per shell.Results: The method substantially reduces both the spatial inhomogeneity of the computed mean diffusivities (MD) and the computed values of the fractional anisotropy (FA), as well as virtually eliminating any artifactual directional bias in the tensor field secondary to gradient nonlinearity. When a small scaling miscalibration was purposely introduced in the x, y, and z, the method accurately detected the amount of miscalibration on each gradient axis.Conclusion: The method presented detects and corrects the effects of gradient nonlinearity and gradient gain miscalibration using a simple isotropic diffusion phantom. The correction would improve the accuracy of DMRI measurements in the brain and other organs for both DTI and higher order diffusion analysis. In particular, it would allow calibration of MRI systems, improving data harmony in multicenter studies.
- 4 August 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (6) , 3259-3273
Open AccessMapping gradient nonlinearity and miscalibration using diffusion‐weighted MR images of a uniform isotropic phantom
Purpose: To use diffusion measurements to map the spatial dependence of the magnetic field produced by the gradient coils of an MRI scanner with sufficient accuracy to correct errors in quantitative diffusion MRI (DMRI) caused by gradient nonlinearity and gradient amplifier miscalibration.Theory and Methods: The field produced by the gradient coils is expanded in regular solid harmonics. The expansion coefficients are found by fitting a model to a minimum set of diffusion‐weighted images of an isotropic diffusion phantom. The accuracy of the resulting gradient coil field maps is evaluated by using them to compute corrected b‐matrices that are then used to process a multi‐shell diffusion tensor imaging (DTI) dataset with 32 diffusion directions per shell.Results: The method substantially reduces both the spatial inhomogeneity of the computed mean diffusivities (MD) and the computed values of the fractional anisotropy (FA), as well as virtually eliminating any artifactual directional bias in the tensor field secondary to gradient nonlinearity. When a small scaling miscalibration was purposely introduced in the x, y, and z, the method accurately detected the amount of miscalibration on each gradient axis.Conclusion: The method presented detects and corrects the effects of gradient nonlinearity and gradient gain miscalibration using a simple isotropic diffusion phantom. The correction would improve the accuracy of DMRI measurements in the brain and other organs for both DTI and higher order diffusion analysis. In particular, it would allow calibration of MRI systems, improving data harmony in multicenter studies.
- Open Access
Empirical field mapping for gradient nonlinearity correction of multi-site diffusion weighted MRI
Background: Achieving inter-site / inter-scanner reproducibility of diffusion weighted magnetic resonance imaging (DW-MRI) metrics has been challenging given differences in acquisition protocols, analysis models, and hardware factors. Purpose: Magnetic field gradients impart scanner-dependent spatial variations in the applied diffusion weighting that can be corrected if the gradient nonlinearities are known. However, retrieving manufacturer nonlinearity specifications is not well supported and may introduce errors in interpretation of units or coordinate systems. We propose an empirical approach to mapping the gradient nonlinearities with sequences that are supported across the major scanner vendors. Study Type: Prospective observational study Subjects: A spherical isotropic diffusion phantom, and a single human control volunteer Field Strength/Sequence: 3T (two scanners). Stejskal-Tanner spin echo sequence with b-values of 1000, 2000 s/mm 2 with 12, 32, and 384 diffusion gradient directions per shell. Assessment: We compare the proposed correction with the prior approach using manufacturer specifications against typical diffusion pre-processing pipelines (i.e., ignoring spatial gradient nonlinearities). In phantom data, we evaluate metrics against the ground truth. In human and phantom data, we evaluate reproducibility across scans, sessions, and hardware. Statistical Tests: Wilcoxon rank-sum test between uncorrected and corrected data. Results: In phantom data, our correction method reduces variation in mean diffusivity across sessions over uncorrected data (p<0.05). In human data, we show that this method can also reduce variation in mean diffusivity across scanners (p<0.05). Conclusion: Our method is relatively simple, fast, and can be applied retroactively. We advocate incorporating voxel-specific b-value and b-vector maps should be incorporated in DW-MRI harmonization preprocessing pipelines to improve quantitative accuracy of measured diffusion parameters.
Open AccessEmpirical field mapping for gradient nonlinearity correction of multi-site diffusion weighted MRI
Background: Achieving inter-site / inter-scanner reproducibility of diffusion weighted magnetic resonance imaging (DW-MRI) metrics has been challenging given differences in acquisition protocols, analysis models, and hardware factors. Purpose: Magnetic field gradients impart scanner-dependent spatial variations in the applied diffusion weighting that can be corrected if the gradient nonlinearities are known. However, retrieving manufacturer nonlinearity specifications is not well supported and may introduce errors in interpretation of units or coordinate systems. We propose an empirical approach to mapping the gradient nonlinearities with sequences that are supported across the major scanner vendors. Study Type: Prospective observational study Subjects: A spherical isotropic diffusion phantom, and a single human control volunteer Field Strength/Sequence: 3T (two scanners). Stejskal-Tanner spin echo sequence with b-values of 1000, 2000 s/mm 2 with 12, 32, and 384 diffusion gradient directions per shell. Assessment: We compare the proposed correction with the prior approach using manufacturer specifications against typical diffusion pre-processing pipelines (i.e., ignoring spatial gradient nonlinearities). In phantom data, we evaluate metrics against the ground truth. In human and phantom data, we evaluate reproducibility across scans, sessions, and hardware. Statistical Tests: Wilcoxon rank-sum test between uncorrected and corrected data. Results: In phantom data, our correction method reduces variation in mean diffusivity across sessions over uncorrected data (p<0.05). In human data, we show that this method can also reduce variation in mean diffusivity across scanners (p<0.05). Conclusion: Our method is relatively simple, fast, and can be applied retroactively. We advocate incorporating voxel-specific b-value and b-vector maps should be incorporated in DW-MRI harmonization preprocessing pipelines to improve quantitative accuracy of measured diffusion parameters.