Xiao Lei
Xiao Lei has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Dejie Sheng
School of Electrical Engineering, Hebei University of Technology, Tianjin, China
1 shared publication Hong Zeng
State Grid Sichuan Electric Power Research Institute, Chengdu, 610092 China
1 shared publication- Hua Zhang
State Grid Sichuan Electric Power Research Institute, Chengdu 610041, China
1 shared publication - Jiawang Zhou
School of Electrical Engineering, Hebei University of Technology, Tianjin, China
1 shared publication Linhuan Li
State Grid Sichuan Electric Measurement Center, Chengdu, 610000 China
1 shared publicationQiang Liu
State Grid Sichuan Electric Power Research Institute, Chengdu, 610092 China
1 shared publication
Latest Publications
- Open Access
- 11 November 2023
- Published by MDPI AG in Electronics
- Vol. 12 (22) , 4617
Arc_EffNet: A Novel Series Arc Fault Detection Method Based on Lightweight Neural Network
Arc faults can cause a severe electric fire, especially series arc faults. Artificial intelligence (AI)-based arc fault detection methods can have a boasted detection accuracy. However, the complexity and large parameter quantity of the AI-based algorithm will hinder its real-time performance for detecting series arc faults. This paper proposes a lightweight arc fault detection method based on the EffNet module, which can make the algorithm less complex with the same detection accuracy level. An arc fault test platform was constructed to collect arc current data, covering eight types of loads required by the IEC 62606 standard. The raw arc current data are used directly as an input for the proposed algorithm, reducing the module’s complexity. According to features of arc current mainly represented in the time domain, the first and last convolution layers of the EffNet module can be improved. Additionally, the spatially separable convolution is well-tuned and trimmed to achieve a more lightweight and better-performance architecture for arc fault detection called Arc_EffNet. Remarkably, this model achieves an impressive arc detection accuracy of 99.75%. An arc fault detection prototype was built using the Raspberry Pi 4B to evaluate the real-time detecting performance of the proposed method. The experimental results show that the prototype takes a time of about 72 ms to respond to a series arc fault, which can fulfill the requirement of real-time detection for arc faults.
- 11 November 2023
- Published by MDPI AG in Electronics
- Vol. 12 (22) , 4617
Open AccessArc_EffNet: A Novel Series Arc Fault Detection Method Based on Lightweight Neural Network
Arc faults can cause a severe electric fire, especially series arc faults. Artificial intelligence (AI)-based arc fault detection methods can have a boasted detection accuracy. However, the complexity and large parameter quantity of the AI-based algorithm will hinder its real-time performance for detecting series arc faults. This paper proposes a lightweight arc fault detection method based on the EffNet module, which can make the algorithm less complex with the same detection accuracy level. An arc fault test platform was constructed to collect arc current data, covering eight types of loads required by the IEC 62606 standard. The raw arc current data are used directly as an input for the proposed algorithm, reducing the module’s complexity. According to features of arc current mainly represented in the time domain, the first and last convolution layers of the EffNet module can be improved. Additionally, the spatially separable convolution is well-tuned and trimmed to achieve a more lightweight and better-performance architecture for arc fault detection called Arc_EffNet. Remarkably, this model achieves an impressive arc detection accuracy of 99.75%. An arc fault detection prototype was built using the Raspberry Pi 4B to evaluate the real-time detecting performance of the proposed method. The experimental results show that the prototype takes a time of about 72 ms to respond to a series arc fault, which can fulfill the requirement of real-time detection for arc faults.
- Open Access
- 1 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 123777-123785
Research on Resonance Overvoltage of EHV Transmission Lines Caused by Lightning Strike
This paper studies the mechanism and influencing factors of resonance overvoltage of EHV transmission lines caused by lightning. By analyzing the time domain steady state of the simplified resonance circuit, the physical mechanism of resonance is revealed. The characteristics of resonance transient process and overvoltage waveform are analyzed by using electromagnetic transient simulation. The main influencing factors of overvoltage amplitude are also studied. The results show that: 1) During uneven open-phase conditions, resonant circuit involving shunt inductors and line equivalent capacitor obtains energy from lightning strikes, which may lead to resonance. 2) the transient process of resonance can be divided into three stages, including lightning stage, lightning-resonance conversion stage and steady-state resonance stage, among which the voltage of the first two stages are higher; 3) the lightning strike time, lightning current parameters and subsequent lightning strike affect on the overvoltage amplitude, which leads to the random amplitude in overvoltage.
- 1 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 123777-123785
Open AccessResearch on Resonance Overvoltage of EHV Transmission Lines Caused by Lightning Strike
This paper studies the mechanism and influencing factors of resonance overvoltage of EHV transmission lines caused by lightning. By analyzing the time domain steady state of the simplified resonance circuit, the physical mechanism of resonance is revealed. The characteristics of resonance transient process and overvoltage waveform are analyzed by using electromagnetic transient simulation. The main influencing factors of overvoltage amplitude are also studied. The results show that: 1) During uneven open-phase conditions, resonant circuit involving shunt inductors and line equivalent capacitor obtains energy from lightning strikes, which may lead to resonance. 2) the transient process of resonance can be divided into three stages, including lightning stage, lightning-resonance conversion stage and steady-state resonance stage, among which the voltage of the first two stages are higher; 3) the lightning strike time, lightning current parameters and subsequent lightning strike affect on the overvoltage amplitude, which leads to the random amplitude in overvoltage.