D. Seyler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
D. Seyler has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Antonello Ortolan
INFN, Laboratori Nazionali di Legnaro
1 shared publication - Cateriana Braggio
INFN, Sezione di Padova
1 shared publication - Giovanni Carugno
Istituto Nazionale di Fisica Nucleare, Sez. Padova 2 , Padova
1 shared publication - Giuseppe Ruoso
INFN, Laboratori Nazionali di Legnaro
1 shared publication - R. Di Vora
INFN, Laboratori Nazionali di Legnaro
1 shared publication
Latest Publications
- Open Access
- 1 April 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (4)
A tunable clamshell cavity for wavelike dark matter searches
Here, we present a frequency tuning mechanism for microwave cavities designed for axion dark matter searches and show that it provides a range of at least 200 MHz for the fundamental mode TM010 resonant at ∼10 GHz. The apparatus is based on a clamshell cavity, with the two semi-cells held together at a fixed joint while the other side opens to tune the frequency of the resonant modes. Measurements of the cavity frequencies and quality factor were taken at liquid helium temperature as the aperture was increased incrementally to ∼2°. We show that the frequency shift is approximately linear with respect to the angle of aperture with no mode crossings present for an aperture less than 2°. Furthermore, the form factor and quality factor of the TM010 mode remain relatively constant throughout the tuning as predicted by simulation.
- 1 April 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (4)
Open AccessA tunable clamshell cavity for wavelike dark matter searches
Here, we present a frequency tuning mechanism for microwave cavities designed for axion dark matter searches and show that it provides a range of at least 200 MHz for the fundamental mode TM010 resonant at ∼10 GHz. The apparatus is based on a clamshell cavity, with the two semi-cells held together at a fixed joint while the other side opens to tune the frequency of the resonant modes. Measurements of the cavity frequencies and quality factor were taken at liquid helium temperature as the aperture was increased incrementally to ∼2°. We show that the frequency shift is approximately linear with respect to the angle of aperture with no mode crossings present for an aperture less than 2°. Furthermore, the form factor and quality factor of the TM010 mode remain relatively constant throughout the tuning as predicted by simulation.