Jungmin Jo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jungmin Jo has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Ji Yi Lee
Department of Environmental Science and Engineering Ewha Womans University Seoul Republic of Korea
3 shared publications - Yun Gyong Ahn
Metropolitan Seoul Center, Korea Basic Science Institute (KBSI), University-Industry Cooperation Building, 150 Bugahyeon-ro, Seodaemun-gu, Seoul 03759, Republic of Korea
3 shared publications - Amgalan Natsagdorj
Department of Chemistry, National University of Mongolia, Ulaanbaatar, Mongolia
1 shared publication - Atsushi Matsuki
Institute of Nature and Environmental Technology Kanazawa University Kanazawa Japan
1 shared publication - Dong Sik Ahn
Environmental Research Group, Korea Institute of Coastal Ecology, Bucheon 14449, Republic of Korea
1 shared publication - Eunjin Lee
Department of Environmental Science and Engineering, Ewha Womans University, Seoul 03760, Republic of Korea
1 shared publication
Latest Publications
- Open Access
Comparison of Sample Preparation and Detection Methods for the Quantification of Synthetic Musk Compounds (SMCs) in Carp Fish Samples
This study deals with the separation and detection methods for 12 synthetic musk compounds (SMCs), which are some of the emerging contaminants in fish samples, are widely present in environmental media, and can be considered serious risks due to their harmful effects. For the separation of co-extracted substances and the target SMCs in fish samples after ultrasonic extraction, four solid-phase extraction (SPE) sorbents were investigated. The recoveries of SMCs from 10 mL of eluent, as optimized by the elution profile, were within the acceptable range of 80–120% in all SPE types, and it was found that nitro musk and polycyclic musk compounds were separated more clearly in Florisil SPE than others (Aminopropyl, Alumina-N, PSA). Furthermore, the results of measuring the matrix effects by each SPE through the spiking experiments showed that Florisil SPE was superior. The comparison of a gas chromatograph-single quadrupole mass spectrometer (GC-SQ/MS) with selected ion monitoring (SIM) mode and GC-triple quadrupole mass spectrometer (GC-QqQ-MS/MS) with multiple reaction monitoring (MRM) modes regarding the detection method of SMCs showed that the method detection limits (MDLs) of SMCs were on average ten times lower when GC-QqQ-MS/MS with MRM mode was used. The differences between the two methods can provide essential information for selecting an analytical method in related research fields that require appropriate detection levels, such as risk assessment or pollution control.
Open AccessComparison of Sample Preparation and Detection Methods for the Quantification of Synthetic Musk Compounds (SMCs) in Carp Fish Samples
This study deals with the separation and detection methods for 12 synthetic musk compounds (SMCs), which are some of the emerging contaminants in fish samples, are widely present in environmental media, and can be considered serious risks due to their harmful effects. For the separation of co-extracted substances and the target SMCs in fish samples after ultrasonic extraction, four solid-phase extraction (SPE) sorbents were investigated. The recoveries of SMCs from 10 mL of eluent, as optimized by the elution profile, were within the acceptable range of 80–120% in all SPE types, and it was found that nitro musk and polycyclic musk compounds were separated more clearly in Florisil SPE than others (Aminopropyl, Alumina-N, PSA). Furthermore, the results of measuring the matrix effects by each SPE through the spiking experiments showed that Florisil SPE was superior. The comparison of a gas chromatograph-single quadrupole mass spectrometer (GC-SQ/MS) with selected ion monitoring (SIM) mode and GC-triple quadrupole mass spectrometer (GC-QqQ-MS/MS) with multiple reaction monitoring (MRM) modes regarding the detection method of SMCs showed that the method detection limits (MDLs) of SMCs were on average ten times lower when GC-QqQ-MS/MS with MRM mode was used. The differences between the two methods can provide essential information for selecting an analytical method in related research fields that require appropriate detection levels, such as risk assessment or pollution control.
- Open Access
Developing an Improved Strategy for the Analysis of Polychlorinated Dibenzo-p-Dioxins/Furans and Dioxin-like Polychlorinated Biphenyls in Contaminated Soils Using a Combination of a One-Step Cleanup Method and Gas Chromatography with Triple Quadrupole Mass Spectrometry
Soils contaminated with polychlorodibenzo-p-dioxins (PCDDs), polychlorodibenzofurans (PCDFs), and dioxin-like (dl) polychlorinated biphenyls (PCBs), known as persistent organic pollutants (POPs), have garnered global attention because of their toxicity and persistence in the environment. The standard method for target analytes has been used; however, it is an obstacle in large-scale sample analysis due to the comprehensive sample preparation and high-cost instrumental analysis. Thus, analytical development of inexpensive methods with lower barriers to determine PCDDs/Fs and dl-PCBs in soil is needed. In this study, a one-step cleanup method was developed and validated by combining a multilayer silica gel column and Florisil micro-column followed by gas chromatography with triple quadrupole mass spectrometry (GC-QqQ-MS/MS). To optimize the separation and quantification of 17 PCDDs/Fs and 12 dl-PCBs in soils, the sample cleanup and instrumental conditions were investigated. For quantification method validation, spiking experiments were conducted to determine the linearity of the calibration, recovery, and method detection limit of PCDDs/Fs and dl-PCBs using isotopic dilution GC-QqQ-MS/MS. The applicability of the simultaneous determination of PCDDs/Fs and dl-PCBs was confirmed by the recovery of native target congeners and labeled surrogate congeners spiked into the quality-control and actual soil samples. The results were in good agreement with the requirements imposed by standard methods. The findings in this work demonstrated the high accessibility of the sample cleanup and analysis methods for the efficient determination of PCDDs/Fs and dl-PCBs in contaminated soils.
Open AccessDeveloping an Improved Strategy for the Analysis of Polychlorinated Dibenzo-p-Dioxins/Furans and Dioxin-like Polychlorinated Biphenyls in Contaminated Soils Using a Combination of a One-Step Cleanup Method and Gas Chromatography with Triple Quadrupole Mass Spectrometry
Soils contaminated with polychlorodibenzo-p-dioxins (PCDDs), polychlorodibenzofurans (PCDFs), and dioxin-like (dl) polychlorinated biphenyls (PCBs), known as persistent organic pollutants (POPs), have garnered global attention because of their toxicity and persistence in the environment. The standard method for target analytes has been used; however, it is an obstacle in large-scale sample analysis due to the comprehensive sample preparation and high-cost instrumental analysis. Thus, analytical development of inexpensive methods with lower barriers to determine PCDDs/Fs and dl-PCBs in soil is needed. In this study, a one-step cleanup method was developed and validated by combining a multilayer silica gel column and Florisil micro-column followed by gas chromatography with triple quadrupole mass spectrometry (GC-QqQ-MS/MS). To optimize the separation and quantification of 17 PCDDs/Fs and 12 dl-PCBs in soils, the sample cleanup and instrumental conditions were investigated. For quantification method validation, spiking experiments were conducted to determine the linearity of the calibration, recovery, and method detection limit of PCDDs/Fs and dl-PCBs using isotopic dilution GC-QqQ-MS/MS. The applicability of the simultaneous determination of PCDDs/Fs and dl-PCBs was confirmed by the recovery of native target congeners and labeled surrogate congeners spiked into the quality-control and actual soil samples. The results were in good agreement with the requirements imposed by standard methods. The findings in this work demonstrated the high accessibility of the sample cleanup and analysis methods for the efficient determination of PCDDs/Fs and dl-PCBs in contaminated soils.
- Open Access
Development of Quantitative Chemical Ionization Using Gas Chromatography/Mass Spectrometry and Gas Chromatography/Tandem Mass Spectrometry for Ambient Nitro- and Oxy-PAHs and Its Applications
The concentration of polycyclic aromatic hydrocarbons (PAHs) in the atmosphere has been continually monitored since their toxicity became known, whereas nitro-PAHs (NPAHs) and oxy-PAHs (OPAHs), which are derivatives of PAHs by primary emissions or secondary formations in the atmosphere, have gained attention more recently. In this study, a method for the quantification of 18 NPAH and OPAH congeners in the atmosphere based on combined applications of gas chromatography coupled with chemical ionization mass spectrometry is presented. A high sensitivity and selectivity for the quantification of individual NPAH and OPAH congeners without sample preparations from the extract of aerosol samples were achieved using negative chemical ionization (NCI/MS) or positive chemical ionization tandem mass spectrometry (PCI-MS/MS). This analytical method was validated and applied to the aerosol samples collected from three regions in Northeast Asia—namely, Noto, Seoul, and Ulaanbaatar—from 15 December 2020 to 17 January 2021. The ranges of the method detection limits (MDLs) of the NPAHs and OPAHs for the analytical method were from 0.272 to 3.494 pg/m3 and 0.977 to 13.345 pg/m3, respectively. Among the three regions, Ulaanbaatar had the highest total mean concentration of NPAHs and OPAHs at 313.803 ± 176.349 ng/m3. The contribution of individual NPAHs and OPAHs in the total concentration differed according to the regional emission characteristics. As a result of the aerosol samples when the developed method was applied, the concentrations of NPAHs and OPAHs were quantified in the ranges of 0.016~3.659 ng/m3 and 0.002~201.704 ng/m3, respectively. It was concluded that the method could be utilized for the quantification of NPAHs and OPAHs over a wide concentration range.
Open AccessDevelopment of Quantitative Chemical Ionization Using Gas Chromatography/Mass Spectrometry and Gas Chromatography/Tandem Mass Spectrometry for Ambient Nitro- and Oxy-PAHs and Its Applications
The concentration of polycyclic aromatic hydrocarbons (PAHs) in the atmosphere has been continually monitored since their toxicity became known, whereas nitro-PAHs (NPAHs) and oxy-PAHs (OPAHs), which are derivatives of PAHs by primary emissions or secondary formations in the atmosphere, have gained attention more recently. In this study, a method for the quantification of 18 NPAH and OPAH congeners in the atmosphere based on combined applications of gas chromatography coupled with chemical ionization mass spectrometry is presented. A high sensitivity and selectivity for the quantification of individual NPAH and OPAH congeners without sample preparations from the extract of aerosol samples were achieved using negative chemical ionization (NCI/MS) or positive chemical ionization tandem mass spectrometry (PCI-MS/MS). This analytical method was validated and applied to the aerosol samples collected from three regions in Northeast Asia—namely, Noto, Seoul, and Ulaanbaatar—from 15 December 2020 to 17 January 2021. The ranges of the method detection limits (MDLs) of the NPAHs and OPAHs for the analytical method were from 0.272 to 3.494 pg/m3 and 0.977 to 13.345 pg/m3, respectively. Among the three regions, Ulaanbaatar had the highest total mean concentration of NPAHs and OPAHs at 313.803 ± 176.349 ng/m3. The contribution of individual NPAHs and OPAHs in the total concentration differed according to the regional emission characteristics. As a result of the aerosol samples when the developed method was applied, the concentrations of NPAHs and OPAHs were quantified in the ranges of 0.016~3.659 ng/m3 and 0.002~201.704 ng/m3, respectively. It was concluded that the method could be utilized for the quantification of NPAHs and OPAHs over a wide concentration range.