YZYalei Zhao

Yalei Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yalei Zhao has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Numerical Simulation for Lightweight Design of a Liquid Hydrogen Weighing Tank for Flow Standard

    by Xiang Li, Menghui Wu, Xianlei Chen, Yu Meng, Xiaobin Zhang, Weijie Chen, Shanyi Xu, Naifeng Nie, Yongcheng Zhu, Jianan Zhou, et al.

    To improve the accuracy of gravimetric liquid hydrogen flow standard devices, the self-weight of the weighing tank must be minimized, because the total mass of the liquid hydrogen contained in the tank is far smaller than the structural mass of the tank itself, which severely compromises the sensitivity of gravimetric measurement. In this study, a three-dimensional finite element model of a vacuum-insulated liquid-hydrogen weighing tank was developed in ABAQUS. The inner and outer shells were modeled with 06Cr19Ni10 (304) and 06Cr17Ni12Mo2 (316) austenitic stainless steels, and Polyamide 6 (PA6) was used for the internal support. Three operating stages were considered: evacuation of the annulus (interlayer pressure reduced from 0.1 MPa to 0 MPa), pre-cooling to −253 °C, and pressurization of the inner tank (internal pressure increased from 0.1 MPa to 1 MPa). The equivalent stress and deformation were compared for different materials and wall thicknesses to evaluate structural safety and weight-reduction potential. The proposed configuration (inner shell 1.6 mm and outer shell 1.0 mm) achieves a mass reduction of more than 50% relative to the 3 mm minimum wall thickness commonly adopted for cryogenic vessels, while keeping stresses below the allowable limits. This reduction enables the use of higher-resolution load cells and thereby lowering the measurement uncertainty of the liquid hydrogen flow standard device and providing technical support for lightweight and cost-effective design, with potential applicability to other cryogenic tank systems.

  • Open Access

    Numerical Study of Liquid Hydrogen Internal Flow in Liquid Hydrogen Storage Tank

    by Xiang Li, Qun Wei, Lianyan Yu, Xiaobin Zhang, Yiting Zou, Yongcheng Zhu, Yanbo Peng, Daolin Wang, Zexian Zhu, Xianlei Chen, et al.

    As a key zero-carbon energy carrier, the accurate measurement of liquid hydrogen flow in its industrial chain is crucial. However, the ultra-low temperature, ultra-low density and other properties of liquid hydrogen can introduce calibration errors. To enhance the measurement accuracy and reliability of liquid hydrogen flow, this study investigates the heat and mass transfer within a 1 m3 non-vented storage tank during the calibration process of a liquid hydrogen flow standard device that integrates combined dynamic and static gravimetric methods. The vertical tank configuration was selected to minimize the vapor–liquid interface area, thereby suppressing boil-off gas generation and enhancing pressure stability, which is critical for measurement accuracy. Building upon research on cryogenic flow standard devices as well as tank experiments and simulations, this study employs computational fluid dynamics (CFD) with Fluent 2024 software to numerically simulate liquid hydrogen flow within a non-vented tank. The thermophysical properties of hydrogen, crucial for the accuracy of the phase-change simulation, were implemented using high-fidelity real-fluid data from the NIST Standard Reference Database, as the ideal gas law is invalid under the cryogenic conditions studied. Specifically, the Lee model was enhanced via User-Defined Functions (UDFs) to accurately simulate the key phase-change processes, involving coupled flash evaporation and condensation during liquid hydrogen refueling. The simulation results demonstrated good agreement with NASA experimental data. This study systematically examined the effects of key parameters, including inlet flow conditions and inlet liquid temperature, on the flow characteristics of liquid hydrogen entering the tank and the subsequent heat and mass transfer behavior within the tank. The results indicated that an increase in mass flow rate elevates tank pressure and reduces filling time. Conversely, a decrease in the inlet liquid hydrogen temperature significantly intensifies heat and mass transfer during the initial refueling stage. These findings provide important theoretical support for a deeper understanding of the complex physical mechanisms of liquid hydrogen flow calibration in non-vented tanks and for optimizing calibration accuracy.


  • Open Access

    Numerical Study on the Effect of Upstream Piping Configuration on Flow Diverter Performance

    by Xiang Li, Menghui Wu, Xianlei Chen, Yu Meng, Xiaobin Zhang, Qingsong Shi, Shanyi Xu, Naifeng Nie, Daolin Wang, Zexian Zu, et al.

    Liquid hydrogen, a cryogenic fluid with extremely low density and viscosity, plays a crucial role in zero-carbon energy strategies. It has become a prominent research focus in the field of new energy strategy. In most processes within the liquid hydrogen industry chain, liquid hydrogen flow measurement is involved. This paper focuses on the study of the flow diverter, a key component of the liquid hydrogen flow standard device. Aiming at the high thermal insulation requirement of liquid hydrogen, the straight piping in the conventional flow standard device is optimized. A combined coiled-vertical piping with key equipment is enclosed in a vacuum cold box for centralized thermal insulation. Fluid flow during diverter switching under four piping configurations was simulated using ANSYS Fluent for both water and liquid hydrogen. The influence of piping structure on flow error during the switching of the diverter is systematically studied. From the simulation results, it can be concluded that the U-shaped piping effectively avoids the inertia and overshoot effects during fluid switching, which helps to reduce errors caused by commutation.

  • Open Access

    Numerical Study of Liquid Hydrogen Internal Flow in Liquid Hydrogen Storage Tank

    by Xiang Li, Qun Wei, Lianyan Yu, Xiaobin Zhang, Yiting Zou, Yongcheng Zhu, Yanbo Peng, Daolin Wang, Zexian Zhu, Zelei Chen, et al.

    As a key zero-carbon energy carrier, the accurate measurement of liquid hydrogen flow in its industrial chain is crucial. However, the ultra-low temperature, ultra-low density and other properties of liquid hydrogen can introduce calibration errors. To enhance the measurement accuracy and reliability of liquid hydrogen flow, this study investigates the heat and mass transfer within a 1 m3 non-vented storage tank during the calibration process of a liquid hydrogen flow standard device that integrates combined dynamic and static gravimetric methods. Building upon research on cryogenic flow standard devices as well as tank experiments and simulations, this study employs computational fluid dynamics (CFD) with Fluent software to numerically simulate liquid hydrogen flow within the non-vented tank. Specifically, the Lee model was enhanced via user-defined functions (UDF) to accurately simulate the key phase-change processes, involving coupled flash evaporation and condensation, during liquid hydrogen refueling. The simulation results demonstrated good agreement with NASA experimental data. This study systematically examined the effects of key parameters, including inlet flow conditions and inlet liquid temperature, on the flow characteristics of liquid hydrogen entering the tank and the subsequent heat and mass transfer behavior within the tank. The results indicated that an increase in mass flow rate elevates tank pressure and reduces filling time. Conversely, a decrease in the inlet liquid hydrogen temperature significantly intensifies heat and mass transfer during the initial refueling stage.These findings provide important theoretical support for a deeper understanding of the complex physical mechanisms of liquid hydrogen flow calibration in non-vented tanks and for optimizing calibration accuracy.


  • Open Access

    Dynamic Characterization of Thermocouples under Double-Pulse Laser-Induced Thermal Excitation

    by Hongbo Yang, Chengxu Tu, Zhouxia Jia, Qingfu Meng, Jinghao Zhang, Jiaxiang Wang, Yalei Zhao, Chenbin Zhu, Fubing Bao

    This study investigated the dynamic characteristics of thermocouples by using double-pulse laser excitation for dynamic temperature calibration under extreme conditions. An experimental device was constructed for double-pulse laser calibration; the device uses a digital pulse delay trigger to precisely control the double-pulse laser to achieve sub-microsecond dual temperature excitation with adjustable time intervals. The time constants of thermocouples under single-pulse laser excitation and double-pulse laser excitation were evaluated. In addition, the variation trends of thermocouple time constants under different double-pulse laser time intervals were analyzed. The experimental results indicated that the time constant increases and then decreases with the decrease in the time interval of the double-pulse laser. A method for dynamic temperature calibration was established for the evaluation of the dynamic characteristics of temperature sensors.