Xiang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiang Li has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Chengxu Tu
Zhejiang Provincial Key Laboratory of Flow Measurement Technology, China Jiliang University, Hangzhou 310018, China
4 shared publications - Fubing Bao
Zhejiang Provincial Key Laboratory of Flow Measurement Technology, China Jiliang University, Hangzhou 310018, China
4 shared publications - Xianlei Chen
Zhoushan Institute of Calibration and Testing for Quality and Technology Supervision, Zhoushan 316000, China
4 shared publications - Xiaobin Zhang
Zhejiang University, China
4 shared publications - Yalei Zhao
Zhejiang Provincial Key Laboratory of Flow Measurement Technology, China Jiliang University, Hangzhou 310018, China
4 shared publications - Yongcheng Zhu
College of Metrology Measurement and Instrument, China Jiliang University, Hangzhou 310018, China
3 shared publications
Latest Publications
- Open Access
- 21 January 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (2) , 1111
Numerical Simulation for Lightweight Design of a Liquid Hydrogen Weighing Tank for Flow Standard
To improve the accuracy of gravimetric liquid hydrogen flow standard devices, the self-weight of the weighing tank must be minimized, because the total mass of the liquid hydrogen contained in the tank is far smaller than the structural mass of the tank itself, which severely compromises the sensitivity of gravimetric measurement. In this study, a three-dimensional finite element model of a vacuum-insulated liquid-hydrogen weighing tank was developed in ABAQUS. The inner and outer shells were modeled with 06Cr19Ni10 (304) and 06Cr17Ni12Mo2 (316) austenitic stainless steels, and Polyamide 6 (PA6) was used for the internal support. Three operating stages were considered: evacuation of the annulus (interlayer pressure reduced from 0.1 MPa to 0 MPa), pre-cooling to −253 °C, and pressurization of the inner tank (internal pressure increased from 0.1 MPa to 1 MPa). The equivalent stress and deformation were compared for different materials and wall thicknesses to evaluate structural safety and weight-reduction potential. The proposed configuration (inner shell 1.6 mm and outer shell 1.0 mm) achieves a mass reduction of more than 50% relative to the 3 mm minimum wall thickness commonly adopted for cryogenic vessels, while keeping stresses below the allowable limits. This reduction enables the use of higher-resolution load cells and thereby lowering the measurement uncertainty of the liquid hydrogen flow standard device and providing technical support for lightweight and cost-effective design, with potential applicability to other cryogenic tank systems.
- 21 January 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (2) , 1111
Open AccessNumerical Simulation for Lightweight Design of a Liquid Hydrogen Weighing Tank for Flow Standard
To improve the accuracy of gravimetric liquid hydrogen flow standard devices, the self-weight of the weighing tank must be minimized, because the total mass of the liquid hydrogen contained in the tank is far smaller than the structural mass of the tank itself, which severely compromises the sensitivity of gravimetric measurement. In this study, a three-dimensional finite element model of a vacuum-insulated liquid-hydrogen weighing tank was developed in ABAQUS. The inner and outer shells were modeled with 06Cr19Ni10 (304) and 06Cr17Ni12Mo2 (316) austenitic stainless steels, and Polyamide 6 (PA6) was used for the internal support. Three operating stages were considered: evacuation of the annulus (interlayer pressure reduced from 0.1 MPa to 0 MPa), pre-cooling to −253 °C, and pressurization of the inner tank (internal pressure increased from 0.1 MPa to 1 MPa). The equivalent stress and deformation were compared for different materials and wall thicknesses to evaluate structural safety and weight-reduction potential. The proposed configuration (inner shell 1.6 mm and outer shell 1.0 mm) achieves a mass reduction of more than 50% relative to the 3 mm minimum wall thickness commonly adopted for cryogenic vessels, while keeping stresses below the allowable limits. This reduction enables the use of higher-resolution load cells and thereby lowering the measurement uncertainty of the liquid hydrogen flow standard device and providing technical support for lightweight and cost-effective design, with potential applicability to other cryogenic tank systems.
- Open Access
Numerical Study of Liquid Hydrogen Internal Flow in Liquid Hydrogen Storage Tank
As a key zero-carbon energy carrier, the accurate measurement of liquid hydrogen flow in its industrial chain is crucial. However, the ultra-low temperature, ultra-low density and other properties of liquid hydrogen can introduce calibration errors. To enhance the measurement accuracy and reliability of liquid hydrogen flow, this study investigates the heat and mass transfer within a 1 m3 non-vented storage tank during the calibration process of a liquid hydrogen flow standard device that integrates combined dynamic and static gravimetric methods. The vertical tank configuration was selected to minimize the vapor–liquid interface area, thereby suppressing boil-off gas generation and enhancing pressure stability, which is critical for measurement accuracy. Building upon research on cryogenic flow standard devices as well as tank experiments and simulations, this study employs computational fluid dynamics (CFD) with Fluent 2024 software to numerically simulate liquid hydrogen flow within a non-vented tank. The thermophysical properties of hydrogen, crucial for the accuracy of the phase-change simulation, were implemented using high-fidelity real-fluid data from the NIST Standard Reference Database, as the ideal gas law is invalid under the cryogenic conditions studied. Specifically, the Lee model was enhanced via User-Defined Functions (UDFs) to accurately simulate the key phase-change processes, involving coupled flash evaporation and condensation during liquid hydrogen refueling. The simulation results demonstrated good agreement with NASA experimental data. This study systematically examined the effects of key parameters, including inlet flow conditions and inlet liquid temperature, on the flow characteristics of liquid hydrogen entering the tank and the subsequent heat and mass transfer behavior within the tank. The results indicated that an increase in mass flow rate elevates tank pressure and reduces filling time. Conversely, a decrease in the inlet liquid hydrogen temperature significantly intensifies heat and mass transfer during the initial refueling stage. These findings provide important theoretical support for a deeper understanding of the complex physical mechanisms of liquid hydrogen flow calibration in non-vented tanks and for optimizing calibration accuracy.
Open AccessNumerical Study of Liquid Hydrogen Internal Flow in Liquid Hydrogen Storage Tank
As a key zero-carbon energy carrier, the accurate measurement of liquid hydrogen flow in its industrial chain is crucial. However, the ultra-low temperature, ultra-low density and other properties of liquid hydrogen can introduce calibration errors. To enhance the measurement accuracy and reliability of liquid hydrogen flow, this study investigates the heat and mass transfer within a 1 m3 non-vented storage tank during the calibration process of a liquid hydrogen flow standard device that integrates combined dynamic and static gravimetric methods. The vertical tank configuration was selected to minimize the vapor–liquid interface area, thereby suppressing boil-off gas generation and enhancing pressure stability, which is critical for measurement accuracy. Building upon research on cryogenic flow standard devices as well as tank experiments and simulations, this study employs computational fluid dynamics (CFD) with Fluent 2024 software to numerically simulate liquid hydrogen flow within a non-vented tank. The thermophysical properties of hydrogen, crucial for the accuracy of the phase-change simulation, were implemented using high-fidelity real-fluid data from the NIST Standard Reference Database, as the ideal gas law is invalid under the cryogenic conditions studied. Specifically, the Lee model was enhanced via User-Defined Functions (UDFs) to accurately simulate the key phase-change processes, involving coupled flash evaporation and condensation during liquid hydrogen refueling. The simulation results demonstrated good agreement with NASA experimental data. This study systematically examined the effects of key parameters, including inlet flow conditions and inlet liquid temperature, on the flow characteristics of liquid hydrogen entering the tank and the subsequent heat and mass transfer behavior within the tank. The results indicated that an increase in mass flow rate elevates tank pressure and reduces filling time. Conversely, a decrease in the inlet liquid hydrogen temperature significantly intensifies heat and mass transfer during the initial refueling stage. These findings provide important theoretical support for a deeper understanding of the complex physical mechanisms of liquid hydrogen flow calibration in non-vented tanks and for optimizing calibration accuracy.
- Open Access
- 7 October 2025
- Published by MDPI AG in Preprints.org
Numerical Study on the Effect of Upstream Piping Configuration on Flow Diverter Performance
Liquid hydrogen, a cryogenic fluid with extremely low density and viscosity, plays a crucial role in zero-carbon energy strategies. It has become a prominent research focus in the field of new energy strategy. In most processes within the liquid hydrogen industry chain, liquid hydrogen flow measurement is involved. This paper focuses on the study of the flow diverter, a key component of the liquid hydrogen flow standard device. Aiming at the high thermal insulation requirement of liquid hydrogen, the straight piping in the conventional flow standard device is optimized. A combined coiled-vertical piping with key equipment is enclosed in a vacuum cold box for centralized thermal insulation. Fluid flow during diverter switching under four piping configurations was simulated using ANSYS Fluent for both water and liquid hydrogen. The influence of piping structure on flow error during the switching of the diverter is systematically studied. From the simulation results, it can be concluded that the U-shaped piping effectively avoids the inertia and overshoot effects during fluid switching, which helps to reduce errors caused by commutation.
- 7 October 2025
- Published by MDPI AG in Preprints.org
Open AccessNumerical Study on the Effect of Upstream Piping Configuration on Flow Diverter Performance
Liquid hydrogen, a cryogenic fluid with extremely low density and viscosity, plays a crucial role in zero-carbon energy strategies. It has become a prominent research focus in the field of new energy strategy. In most processes within the liquid hydrogen industry chain, liquid hydrogen flow measurement is involved. This paper focuses on the study of the flow diverter, a key component of the liquid hydrogen flow standard device. Aiming at the high thermal insulation requirement of liquid hydrogen, the straight piping in the conventional flow standard device is optimized. A combined coiled-vertical piping with key equipment is enclosed in a vacuum cold box for centralized thermal insulation. Fluid flow during diverter switching under four piping configurations was simulated using ANSYS Fluent for both water and liquid hydrogen. The influence of piping structure on flow error during the switching of the diverter is systematically studied. From the simulation results, it can be concluded that the U-shaped piping effectively avoids the inertia and overshoot effects during fluid switching, which helps to reduce errors caused by commutation.
- Open Access
- 1 October 2025
- Published by MDPI AG in Preprints.org
Numerical Study of Liquid Hydrogen Internal Flow in Liquid Hydrogen Storage Tank
As a key zero-carbon energy carrier, the accurate measurement of liquid hydrogen flow in its industrial chain is crucial. However, the ultra-low temperature, ultra-low density and other properties of liquid hydrogen can introduce calibration errors. To enhance the measurement accuracy and reliability of liquid hydrogen flow, this study investigates the heat and mass transfer within a 1 m3 non-vented storage tank during the calibration process of a liquid hydrogen flow standard device that integrates combined dynamic and static gravimetric methods. Building upon research on cryogenic flow standard devices as well as tank experiments and simulations, this study employs computational fluid dynamics (CFD) with Fluent software to numerically simulate liquid hydrogen flow within the non-vented tank. Specifically, the Lee model was enhanced via user-defined functions (UDF) to accurately simulate the key phase-change processes, involving coupled flash evaporation and condensation, during liquid hydrogen refueling. The simulation results demonstrated good agreement with NASA experimental data. This study systematically examined the effects of key parameters, including inlet flow conditions and inlet liquid temperature, on the flow characteristics of liquid hydrogen entering the tank and the subsequent heat and mass transfer behavior within the tank. The results indicated that an increase in mass flow rate elevates tank pressure and reduces filling time. Conversely, a decrease in the inlet liquid hydrogen temperature significantly intensifies heat and mass transfer during the initial refueling stage.These findings provide important theoretical support for a deeper understanding of the complex physical mechanisms of liquid hydrogen flow calibration in non-vented tanks and for optimizing calibration accuracy.
- 1 October 2025
- Published by MDPI AG in Preprints.org
Open AccessNumerical Study of Liquid Hydrogen Internal Flow in Liquid Hydrogen Storage Tank
As a key zero-carbon energy carrier, the accurate measurement of liquid hydrogen flow in its industrial chain is crucial. However, the ultra-low temperature, ultra-low density and other properties of liquid hydrogen can introduce calibration errors. To enhance the measurement accuracy and reliability of liquid hydrogen flow, this study investigates the heat and mass transfer within a 1 m3 non-vented storage tank during the calibration process of a liquid hydrogen flow standard device that integrates combined dynamic and static gravimetric methods. Building upon research on cryogenic flow standard devices as well as tank experiments and simulations, this study employs computational fluid dynamics (CFD) with Fluent software to numerically simulate liquid hydrogen flow within the non-vented tank. Specifically, the Lee model was enhanced via user-defined functions (UDF) to accurately simulate the key phase-change processes, involving coupled flash evaporation and condensation, during liquid hydrogen refueling. The simulation results demonstrated good agreement with NASA experimental data. This study systematically examined the effects of key parameters, including inlet flow conditions and inlet liquid temperature, on the flow characteristics of liquid hydrogen entering the tank and the subsequent heat and mass transfer behavior within the tank. The results indicated that an increase in mass flow rate elevates tank pressure and reduces filling time. Conversely, a decrease in the inlet liquid hydrogen temperature significantly intensifies heat and mass transfer during the initial refueling stage.These findings provide important theoretical support for a deeper understanding of the complex physical mechanisms of liquid hydrogen flow calibration in non-vented tanks and for optimizing calibration accuracy.
- Open Access
- 31 August 2023
- Published by MDPI AG in Lubricants
- Vol. 11 (9) , 367
Influence of Nitrile Butadiene Rubber (NBR) Shore Hardness and Polytetrafluoroethylene (PTFE) Elastic Modulus on the Sealing Characteristics of Step Rod Seals
The influence of NBR Shore hardness and PTFE elastic modulus on the sealing characteristics of step rod seals is analyzed in this paper based on the developed mixed elastohydrodynamic lubrication (EHL) model. The optimized selection studies of NBR Shore hardness and PTFE elastic modulus under different operating conditions are carried out based on the principle of minimizing net leakage and friction power loss. Results show that the Shore hardness of the NBR O-ring and, in particular, the elastic modulus of the PTFE ring has a significant effect on the sealing characteristics. Although the high values of these parameters result in high friction forces, they are beneficial for leakage control. To achieve both low leakage and low friction, it is recommended that high hardness and low modulus are selected for moderate-low pressure or high speed conditions, but low hardness and high modulus are selected for high pressure or low speed conditions.
- 31 August 2023
- Published by MDPI AG in Lubricants
- Vol. 11 (9) , 367
Open AccessInfluence of Nitrile Butadiene Rubber (NBR) Shore Hardness and Polytetrafluoroethylene (PTFE) Elastic Modulus on the Sealing Characteristics of Step Rod Seals
The influence of NBR Shore hardness and PTFE elastic modulus on the sealing characteristics of step rod seals is analyzed in this paper based on the developed mixed elastohydrodynamic lubrication (EHL) model. The optimized selection studies of NBR Shore hardness and PTFE elastic modulus under different operating conditions are carried out based on the principle of minimizing net leakage and friction power loss. Results show that the Shore hardness of the NBR O-ring and, in particular, the elastic modulus of the PTFE ring has a significant effect on the sealing characteristics. Although the high values of these parameters result in high friction forces, they are beneficial for leakage control. To achieve both low leakage and low friction, it is recommended that high hardness and low modulus are selected for moderate-low pressure or high speed conditions, but low hardness and high modulus are selected for high pressure or low speed conditions.