Jingxuan Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jingxuan Xu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Xi Chen
6 shared publicationsJun Gong
4 shared publications- Ting He
Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200240, China
4 shared publications - Xi Chen
School of Energy and Power Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai, China
4 shared publications - Yilin Lu4 shared publications
Hua Zhang
3 shared publications
Latest Publications
- Open Access
- 14 October 2026
- Published by Elsevier in SSRN Electronic Journal
Energy, Exergy, and Life-cycle Economic Assessment of a Polygeneration Liquid Air Energy Storage System Integrating LNG Cold Energy, Solar Energy, and Hydrate‐Based Desalination
The increasing demand for flexible energy storage and pure water production has motivated the development of integrated energy–water systems. Although standalone LAES systems can support large-scale storage, their performance is limited by the electricity required for air compression and liquefaction. Conventional desalination technologies also consume substantial energy and may cause environmental impacts. This study evaluates a multigeneration LAES system integrating LNG cold energy, solar energy, and hydrate-based desalination (LNG-HBD-SALAES). The results indicate that the system produces 2338.83 t/d of pure water and achieves an electrical round-trip efficiency (ERTE) of 144.16% and an overall exergy efficiency of 69.49%. Its economic viability at coastal LNG receiving terminals is examined through a life-cycle cost analysis using representative regional price scenarios. The system requires an initial investment of 90.59 million USD. Among the investigated regional price scenarios, the Liaoning scenario yields the lowest LCOE of 0.142 USD/kWh, whereas the Guangdong scenario provides the highest NPV of 198.12 million USD, with an IRR of 27.28%. Within the parameter ranges considered in this study, sensitivity analysis identifies the LNG regasification fee as the parameter producing the largest variation in project value, with the discount rate, tax rate, and equipment purchase cost next in importance. These parameters should therefore receive particular attention in project investment and operation planning. The assessment provides a reference for evaluating the technical feasibility and economic prospects of combined energy storage and pure water production.
- 14 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEnergy, Exergy, and Life-cycle Economic Assessment of a Polygeneration Liquid Air Energy Storage System Integrating LNG Cold Energy, Solar Energy, and Hydrate‐Based Desalination
The increasing demand for flexible energy storage and pure water production has motivated the development of integrated energy–water systems. Although standalone LAES systems can support large-scale storage, their performance is limited by the electricity required for air compression and liquefaction. Conventional desalination technologies also consume substantial energy and may cause environmental impacts. This study evaluates a multigeneration LAES system integrating LNG cold energy, solar energy, and hydrate-based desalination (LNG-HBD-SALAES). The results indicate that the system produces 2338.83 t/d of pure water and achieves an electrical round-trip efficiency (ERTE) of 144.16% and an overall exergy efficiency of 69.49%. Its economic viability at coastal LNG receiving terminals is examined through a life-cycle cost analysis using representative regional price scenarios. The system requires an initial investment of 90.59 million USD. Among the investigated regional price scenarios, the Liaoning scenario yields the lowest LCOE of 0.142 USD/kWh, whereas the Guangdong scenario provides the highest NPV of 198.12 million USD, with an IRR of 27.28%. Within the parameter ranges considered in this study, sensitivity analysis identifies the LNG regasification fee as the parameter producing the largest variation in project value, with the discount rate, tax rate, and equipment purchase cost next in importance. These parameters should therefore receive particular attention in project investment and operation planning. The assessment provides a reference for evaluating the technical feasibility and economic prospects of combined energy storage and pure water production.
- Open Access
- 3 August 2026
- Published by Elsevier in SSRN Electronic Journal
Optimization and Evaluation of Cryo-compressed Hydrogen Storage System Coupled with Multiple Ortho-Para Conversion Methods
Cryo-compressed hydrogen (CcH2) storage cools hydrogen to cryogenic temperatures and pressurizes it into a supercritical state, combining the high density of liquid hydrogen with the rapid charging/discharging characteristics of compressed gaseous hydrogen. However, ortho-to-para conversion at cryogenic temperatures releases heat, affecting preparation energy consumption and long-term storage stability. To address energy-density coupling in CcH2 design, this study proposes a density energy consumption (DEC) index to quantify the trade-off between energy consumption and storage density. Guided by this index, 100 K and 40 MPa are selected as preferred conditions, and a CcH2 preparation process is developed using a cascaded mixed-refrigerant system. The benchmark process achieves a storage density of 58.36 kg/m3 and a specific energy consumption (SEC) of 4.355 kWh/kg. For long-term storage, three independent CcH2 processes are developed by separately coupling the baseline process with isothermal, adiabatic, or continuous ortho-para conversion heat management. These schemes are compared through thermodynamic and techno-economic analyses. Results show that continuous conversion distributes and removes conversion heat along the cooling path, improves thermal matching, reduces cold-end heat load, and achieves the lowest SEC of 4.442 kWh/kg among the conversion schemes. Techno-economic analysis of the optimal continuous conversion process gives a levelized cost of cryo-compressed hydrogen (LCOH) of $5.58/kg and an internal rate of return of 10.7%. This work identifies an energy-density-favorable CcH2 preparation route and demonstrates continuous conversion as a promising strategy for long-term hydrogen storage.
- 3 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOptimization and Evaluation of Cryo-compressed Hydrogen Storage System Coupled with Multiple Ortho-Para Conversion Methods
Cryo-compressed hydrogen (CcH2) storage cools hydrogen to cryogenic temperatures and pressurizes it into a supercritical state, combining the high density of liquid hydrogen with the rapid charging/discharging characteristics of compressed gaseous hydrogen. However, ortho-to-para conversion at cryogenic temperatures releases heat, affecting preparation energy consumption and long-term storage stability. To address energy-density coupling in CcH2 design, this study proposes a density energy consumption (DEC) index to quantify the trade-off between energy consumption and storage density. Guided by this index, 100 K and 40 MPa are selected as preferred conditions, and a CcH2 preparation process is developed using a cascaded mixed-refrigerant system. The benchmark process achieves a storage density of 58.36 kg/m3 and a specific energy consumption (SEC) of 4.355 kWh/kg. For long-term storage, three independent CcH2 processes are developed by separately coupling the baseline process with isothermal, adiabatic, or continuous ortho-para conversion heat management. These schemes are compared through thermodynamic and techno-economic analyses. Results show that continuous conversion distributes and removes conversion heat along the cooling path, improves thermal matching, reduces cold-end heat load, and achieves the lowest SEC of 4.442 kWh/kg among the conversion schemes. Techno-economic analysis of the optimal continuous conversion process gives a levelized cost of cryo-compressed hydrogen (LCOH) of $5.58/kg and an internal rate of return of 10.7%. This work identifies an energy-density-favorable CcH2 preparation route and demonstrates continuous conversion as a promising strategy for long-term hydrogen storage.
- Open Access
- 1 July 2026
- Published by Elsevier in SSRN Electronic Journal
Optimization and Evaluation of Cryo-compressed Hydrogen Storage System Coupled with Multiple Ortho-Para Conversion Methods
Cryo-compressed hydrogen (CcH2) is an advanced high-density physical hydrogen storage approach. Current research in this field has predominantly focused on the cooling process of CcH2, with limited research on the effect of ortho-para hydrogen conversion (OPC) heat on the stable dormancy period of hydrogen within storage vessels. In this study, a cryo-compressed hydrogen storage process integrated with three ortho-para conversion strategies is proposed and optimized. The system is simulated in Aspen HYSYS and optimized using a genetic algorithm (GA) to achieve a lower specific energy consumption (SEC). Thermodynamic analysis indicates that the non-conversion system can achieve a SEC of 4.355 kWh/kg. Among the OPC systems, the continuous conversion method exhibits the best performance, with a SEC value of 4.442 kWh/kg. This outperforms both the isothermal method and the adiabatic method. Furthermore, this paper introduces the concept of density energy consumption (DEC) to evaluate the trade-off between storage density and energy utilization. Theoretical calculations demonstrate that the energy required to increase the unit storage density decreases as the temperature rises. Techno-economic analysis of the optimal continuous conversion system reveals a levelized cost of hydrogen (LCOH) of $5.58/kg. The project’s feasibility is further confirmed by a positive net present value (NPV) and an internal rate of return (IRR) of 10.7%. This study provides a balanced and efficient solution for CcH2 storage under intermediate cryogenic conditions, offering significant insights for the development of large- and medium-scale supercritical hydrogen storage systems.
- 1 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOptimization and Evaluation of Cryo-compressed Hydrogen Storage System Coupled with Multiple Ortho-Para Conversion Methods
Cryo-compressed hydrogen (CcH2) is an advanced high-density physical hydrogen storage approach. Current research in this field has predominantly focused on the cooling process of CcH2, with limited research on the effect of ortho-para hydrogen conversion (OPC) heat on the stable dormancy period of hydrogen within storage vessels. In this study, a cryo-compressed hydrogen storage process integrated with three ortho-para conversion strategies is proposed and optimized. The system is simulated in Aspen HYSYS and optimized using a genetic algorithm (GA) to achieve a lower specific energy consumption (SEC). Thermodynamic analysis indicates that the non-conversion system can achieve a SEC of 4.355 kWh/kg. Among the OPC systems, the continuous conversion method exhibits the best performance, with a SEC value of 4.442 kWh/kg. This outperforms both the isothermal method and the adiabatic method. Furthermore, this paper introduces the concept of density energy consumption (DEC) to evaluate the trade-off between storage density and energy utilization. Theoretical calculations demonstrate that the energy required to increase the unit storage density decreases as the temperature rises. Techno-economic analysis of the optimal continuous conversion system reveals a levelized cost of hydrogen (LCOH) of $5.58/kg. The project’s feasibility is further confirmed by a positive net present value (NPV) and an internal rate of return (IRR) of 10.7%. This study provides a balanced and efficient solution for CcH2 storage under intermediate cryogenic conditions, offering significant insights for the development of large- and medium-scale supercritical hydrogen storage systems.
- Open Access
- 13 May 2026
- Published by Elsevier in SSRN Electronic Journal
Energy, Exergy, and Economic Analysis of a Polygeneration Liquid Air Energy Storage System Integrating LNG Cold Energy, Solar Energy, and Hydrate‑Based Desalination
The burgeoning global population has heightened concerns regarding energy management and freshwater production. Traditional liquid air energy storage (LAES) systems, while innovative, struggle with low operational efficiency and substantial energy demands. Similarly, conventional desalination methods are impeded by inefficiencies and high energy consumption. Addressing these challenges is indispensable for promoting sustainability of integrated energy and water systems. In this study, an advanced multi-generation liquid air energy storage system combined with liquefied natural gas cold energy, solar energy and hydrate-based desalination (LNG-HBD-SALAES) is analyzed, The results indicate that the system with 2189.01 tons of daily freshwater production has an electrical round-trip efficiency of 148.07% and an exergy efficiency of 72.34%. On this basis, this study further conducts a comprehensive life cycle cost analysis to investigate their potential profitability in typical application scenarios near coastal LNG receiving terminals. Additionally, the sensitivity of the overall economic performance to various parameters is systematically evaluated. The results reveal that the LNG–HBD–SALAES project requires an initial capital investment of 84.60 million USD. When the plant is situated in Liaoning Province, the annual operational and production cost is 6.19 million USD, with the total life cycle cost potentially as low as 200.66 million USD. The LNG-HBD-SALAES system demonstrates optimal economic benefits when located in Guangdong Province, where the levelized cost of energy is 0.113 USD/kWh, and the net present value amounts to 206.17 million USD. Additionally, the detailed sensitivity analysis indicates that the purchase cost of equipment and revenue from the LNG regasification process significantly impact the overall economic performance. These two parameters require focused attention in project investment. This thorough evaluation provides dependable groundwork for the initiation and execution of energy storage projects.
- 13 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEnergy, Exergy, and Economic Analysis of a Polygeneration Liquid Air Energy Storage System Integrating LNG Cold Energy, Solar Energy, and Hydrate‑Based Desalination
The burgeoning global population has heightened concerns regarding energy management and freshwater production. Traditional liquid air energy storage (LAES) systems, while innovative, struggle with low operational efficiency and substantial energy demands. Similarly, conventional desalination methods are impeded by inefficiencies and high energy consumption. Addressing these challenges is indispensable for promoting sustainability of integrated energy and water systems. In this study, an advanced multi-generation liquid air energy storage system combined with liquefied natural gas cold energy, solar energy and hydrate-based desalination (LNG-HBD-SALAES) is analyzed, The results indicate that the system with 2189.01 tons of daily freshwater production has an electrical round-trip efficiency of 148.07% and an exergy efficiency of 72.34%. On this basis, this study further conducts a comprehensive life cycle cost analysis to investigate their potential profitability in typical application scenarios near coastal LNG receiving terminals. Additionally, the sensitivity of the overall economic performance to various parameters is systematically evaluated. The results reveal that the LNG–HBD–SALAES project requires an initial capital investment of 84.60 million USD. When the plant is situated in Liaoning Province, the annual operational and production cost is 6.19 million USD, with the total life cycle cost potentially as low as 200.66 million USD. The LNG-HBD-SALAES system demonstrates optimal economic benefits when located in Guangdong Province, where the levelized cost of energy is 0.113 USD/kWh, and the net present value amounts to 206.17 million USD. Additionally, the detailed sensitivity analysis indicates that the purchase cost of equipment and revenue from the LNG regasification process significantly impact the overall economic performance. These two parameters require focused attention in project investment. This thorough evaluation provides dependable groundwork for the initiation and execution of energy storage projects.
- Open Access
Thermodynamics Analysis of Cryogenic Supercritical Hydrogen Storage System Based on Multi-Stage Joule–Brayton Cycle
The cryogenic supercritical hydrogen storage system offers notable advantages including heightened hydrogen storage density and operation under relatively moderate conditions compared to conventional hydrogen storage methodologies. In this study, a cryogenic supercritical hydrogen storage system based on the multi-stage Joule–Brayton refrigeration cycle is presented, analyzed, and optimized. The proposed system employs a five-stage cascade cycle, each stage utilizes a distinct refrigerant, including propane, ethylene, methane, and hydrogen, facilitated by Joule–Brayton cycles, with expanders employed for mechanical work recovery, which is capable of effectively cooling hydrogen from ambient temperature and atmospheric pressure to a cryogenic supercritical state of −223.15 °C (50 K), 18,000 kPa, exhibiting a density of 73.46 kg/m3 and a hydrogen processing capacity of 2 kgH2/s. The genetic algorithm is applied to optimize 25 key parameters in the system, encompassing temperature, pressure, and flow rate, with the objective function is specific energy consumption. Consequently, the specific energy consumption of the system is 5.71 kWh/kgH2 with an exergy efficiency of 56.2%. Comprehensive energy analysis, heat transfer analysis, and exergy analysis are conducted based on the optimized system parameters, yielding insights crucial for the development of medium- and large-scale supercritical hydrogen storage systems.
Open AccessThermodynamics Analysis of Cryogenic Supercritical Hydrogen Storage System Based on Multi-Stage Joule–Brayton Cycle
The cryogenic supercritical hydrogen storage system offers notable advantages including heightened hydrogen storage density and operation under relatively moderate conditions compared to conventional hydrogen storage methodologies. In this study, a cryogenic supercritical hydrogen storage system based on the multi-stage Joule–Brayton refrigeration cycle is presented, analyzed, and optimized. The proposed system employs a five-stage cascade cycle, each stage utilizes a distinct refrigerant, including propane, ethylene, methane, and hydrogen, facilitated by Joule–Brayton cycles, with expanders employed for mechanical work recovery, which is capable of effectively cooling hydrogen from ambient temperature and atmospheric pressure to a cryogenic supercritical state of −223.15 °C (50 K), 18,000 kPa, exhibiting a density of 73.46 kg/m3 and a hydrogen processing capacity of 2 kgH2/s. The genetic algorithm is applied to optimize 25 key parameters in the system, encompassing temperature, pressure, and flow rate, with the objective function is specific energy consumption. Consequently, the specific energy consumption of the system is 5.71 kWh/kgH2 with an exergy efficiency of 56.2%. Comprehensive energy analysis, heat transfer analysis, and exergy analysis are conducted based on the optimized system parameters, yielding insights crucial for the development of medium- and large-scale supercritical hydrogen storage systems.
- 1 February 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 243
Design and optimization of cryogenic supercritical hydrogen storage system coupled with mixed refrigerant and gas expansion cycle
- 1 February 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 243
Design and optimization of cryogenic supercritical hydrogen storage system coupled with mixed refrigerant and gas expansion cycle