Jeongin Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jeongin Song has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ha Sul Kim
Department of Physics, Chonnam National University, Gwangju 61186, Republic of Korea
1 shared publication - Jae Cheol Shin
Division of Electronics and Electrical Engineering, Dongguk University-Seoul, Seoul 04620, Republic of Korea
1 shared publication - Jaeseo Park
Strategic Technology Research Institute
1 shared publication - Jihun Mun
Strategic Technology Research Institute Korea Research Institute of Standards and Science Daejeon South Korea
1 shared publication - Jongwon Ryu
Advanced Instrumentation Institute, Korea Research Institute of Standards and Science, Daejeon 34113, Republic of Korea
1 shared publication - Sang-Woo Kang
Strategic Technology Research Institute Korea Research Institute of Standards and Science Daejeon Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 31 January 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (3) , 573
Effect of Measurement System Configuration and Operating Conditions on 2D Material-Based Gas Sensor Sensitivity
Gas sensors applied in real-time detection of toxic gas leakage, air pollution, and respiration patterns require a reliable test platform to evaluate their characteristics, such as sensitivity and detection limits. However, securing reliable characteristics of a gas sensor is difficult, owing to the structural difference between the gas sensor measurement platform and the difference in measurement methods. This study investigates the effect of measurement conditions and system configurations on the sensitivity of two-dimensional (2D) material-based gas sensors. Herein, we developed a testbed to evaluate the response characteristics of MoS2-based gas sensors under a NO2 gas flow, which allows variations in their system configurations. Additionally, we demonstrated that the distance between the gas inlet and the sensor and gas inlet orientation influences the sensor performance. As the distance to the 2D gas sensor surface decreased from 4 to 2 mm, the sensitivity of the sensor improved to 9.20%. Furthermore, when the gas inlet orientation was perpendicular to the gas sensor surface, the sensitivity of the sensor was the maximum (4.29%). To attain the optimum operating conditions of the MoS2-based gas sensor, the effects of measurement conditions, such as gas concentration and temperature, on the sensitivity of the gas sensor were investigated.
- 31 January 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (3) , 573
Open AccessEffect of Measurement System Configuration and Operating Conditions on 2D Material-Based Gas Sensor Sensitivity
Gas sensors applied in real-time detection of toxic gas leakage, air pollution, and respiration patterns require a reliable test platform to evaluate their characteristics, such as sensitivity and detection limits. However, securing reliable characteristics of a gas sensor is difficult, owing to the structural difference between the gas sensor measurement platform and the difference in measurement methods. This study investigates the effect of measurement conditions and system configurations on the sensitivity of two-dimensional (2D) material-based gas sensors. Herein, we developed a testbed to evaluate the response characteristics of MoS2-based gas sensors under a NO2 gas flow, which allows variations in their system configurations. Additionally, we demonstrated that the distance between the gas inlet and the sensor and gas inlet orientation influences the sensor performance. As the distance to the 2D gas sensor surface decreased from 4 to 2 mm, the sensitivity of the sensor improved to 9.20%. Furthermore, when the gas inlet orientation was perpendicular to the gas sensor surface, the sensitivity of the sensor was the maximum (4.29%). To attain the optimum operating conditions of the MoS2-based gas sensor, the effects of measurement conditions, such as gas concentration and temperature, on the sensitivity of the gas sensor were investigated.