Jong-Hun Woo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jong-Hun Woo has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Jun-Seop Lee
Kyungpook National University, Daegu, Korea
3 shared publications - Kyung-Jae Shin
Kyungpook National University, Daegu, Korea
3 shared publications - Hee-Du Lee
Regional Center for Land, Infrastructure and Transport Technology, Kyungpook National University, Daegu 41566, Republic of Korea
2 shared publications
Latest Publications
- Open Access
Experimental and Analytical Study on Non-Damaged Reinforcement Method for Pipe Rack Steel Structures
Pipe racks are steel structures that support various pipes transporting materials in industrial complexes. The pipes on pipe racks may transport hazardous substances, which imposes limitations on their structural reinforcement. Therefore, this study aimed to propose methods for reinforcing the joints of pipe rack structures through non-welding and non-drilling techniques. The joints of pipe rack structures were connected by end plates. Initially, this study evaluated the capacity of existing end plates in a real-world experiment and conducted cyclic loading tests with two additional reinforcement methods to validate their performance. Finally, finite element analysis was conducted to explore additional variables that were not covered in the experiments, and the optimal reinforcement method that demonstrated the best performance was proposed.
Open AccessExperimental and Analytical Study on Non-Damaged Reinforcement Method for Pipe Rack Steel Structures
Pipe racks are steel structures that support various pipes transporting materials in industrial complexes. The pipes on pipe racks may transport hazardous substances, which imposes limitations on their structural reinforcement. Therefore, this study aimed to propose methods for reinforcing the joints of pipe rack structures through non-welding and non-drilling techniques. The joints of pipe rack structures were connected by end plates. Initially, this study evaluated the capacity of existing end plates in a real-world experiment and conducted cyclic loading tests with two additional reinforcement methods to validate their performance. Finally, finite element analysis was conducted to explore additional variables that were not covered in the experiments, and the optimal reinforcement method that demonstrated the best performance was proposed.
- Open Access
Design Methodology of U-Shaped Infilled Composite Beams with Angled Shear Connectors Using Finite Element Analysis
A composite beam is a structural member that behaves as a single unit by using shear connectors between a concrete slab and an I-shaped steel girder. The composite ratio is crucial and is determined by the shear connectors’ ability to withstand the horizontal shear forces between the concrete and steel girder. In this study, a U-shaped composite beam was designed, which differs from conventional composite beams as it allows the use of a steel girder as a formwork. Moreover, angle-type shear connectors, instead of stud-type connectors, were employed. Based on this design, large-scale U-shaped composite beams with angle-type shear connectors were fabricated, and load tests were conducted to analyze the behavior after composite action and the influence of shear connector spacing. Additionally, the strength of the angle-type shear connectors used in this paper was evaluated through finite element analysis. Finally, a strength evaluation method for composite beams of this configuration is proposed.
Open AccessDesign Methodology of U-Shaped Infilled Composite Beams with Angled Shear Connectors Using Finite Element Analysis
A composite beam is a structural member that behaves as a single unit by using shear connectors between a concrete slab and an I-shaped steel girder. The composite ratio is crucial and is determined by the shear connectors’ ability to withstand the horizontal shear forces between the concrete and steel girder. In this study, a U-shaped composite beam was designed, which differs from conventional composite beams as it allows the use of a steel girder as a formwork. Moreover, angle-type shear connectors, instead of stud-type connectors, were employed. Based on this design, large-scale U-shaped composite beams with angle-type shear connectors were fabricated, and load tests were conducted to analyze the behavior after composite action and the influence of shear connector spacing. Additionally, the strength of the angle-type shear connectors used in this paper was evaluated through finite element analysis. Finally, a strength evaluation method for composite beams of this configuration is proposed.
- Open Access
- 25 July 2023
- Published by MDPI AG in Preprints.org
FEA of Infilled Composite Beam Using Angle Type Shear Connector
A composite beam is a structural member that behaves as a single unit by using shear connectors between a concrete slab and an H-shaped steel girder. The composite ratio is crucial and determined by the shear connectors' ability to withstand the horizontal shear forces between the concrete and steel girder. In this study, a U-shaped composite beam was designed, which differs from conventional composite beams as it allows the use of a steel girder as a formwork. Moreover, angle-type shear connectors, instead of stud-type connectors, were employed. Based on this design, large-scale U-shaped composite beams with angle-type shear connectors were fabricated, and load tests were conducted to analyze the behavior after composite action and the influence of shear connector spacing. Additionally, the strength of the angle-type shear connectors used in this paper was evaluated through finite element analysis. Finally, a strength evaluation method for composite beams of this configuration was proposed.
- 25 July 2023
- Published by MDPI AG in Preprints.org
Open AccessFEA of Infilled Composite Beam Using Angle Type Shear Connector
A composite beam is a structural member that behaves as a single unit by using shear connectors between a concrete slab and an H-shaped steel girder. The composite ratio is crucial and determined by the shear connectors' ability to withstand the horizontal shear forces between the concrete and steel girder. In this study, a U-shaped composite beam was designed, which differs from conventional composite beams as it allows the use of a steel girder as a formwork. Moreover, angle-type shear connectors, instead of stud-type connectors, were employed. Based on this design, large-scale U-shaped composite beams with angle-type shear connectors were fabricated, and load tests were conducted to analyze the behavior after composite action and the influence of shear connector spacing. Additionally, the strength of the angle-type shear connectors used in this paper was evaluated through finite element analysis. Finally, a strength evaluation method for composite beams of this configuration was proposed.