Albert Doblas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Albert Doblas has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- David Flores
Centro Nacional de Microelectrónica, IMB-CNM-CSIC, 08193 Barcelona, Spain
1 shared publication - David Quirion
IMB CNM CSIC, Ctr Nacl Microelect, Barcelona 08193, Spain
1 shared publication - Dzmitry Maneuski
University of Glasgow
1 shared publication - Giulio Pellegrini
Instituto de Microelectrónica de Barcelona, CNM-CSIC, Campus UAB
1 shared publication - Jairo Villegas
Centro Nacional de Microelectrónica, IMB-CNM-CSIC, 08193 Barcelona, Spain
1 shared publication - Marie Ruat
ESRF – The European Synchrotron, 71 Avenue des Martyrs, Grenoble, Rhône-Alpes, France
1 shared publication
Latest Publications
- Open Access
Inverse LGAD (iLGAD) Periphery Optimization for Surface Damage Irradiation
Pixelated LGADs have been established as the baseline technology for timing detectors for the High Granularity Timing Detector (HGTD) and the Endcap Timing Layer (ETL) of the ATLAS and CMS experiments, respectively. The drawback of segmenting an LGAD is the non-gain area present between pixels and the consequent reduction in the fill factor. To overcome this issue, the inverse LGAD (iLGAD) technology has been proposed by IMB-CNM to enhance the fill factor and provide excellent tracking capabilities. In this work, we explore the use of iLGAD sensors for surface damage irradiation by developing a new generation of iLGADs, the periphery of which is optimized to improve the performance of irradiated sensors. The fabricated iLGAD sensors exhibit good electrical performances before and after X-ray irradiation.
Open AccessInverse LGAD (iLGAD) Periphery Optimization for Surface Damage Irradiation
Pixelated LGADs have been established as the baseline technology for timing detectors for the High Granularity Timing Detector (HGTD) and the Endcap Timing Layer (ETL) of the ATLAS and CMS experiments, respectively. The drawback of segmenting an LGAD is the non-gain area present between pixels and the consequent reduction in the fill factor. To overcome this issue, the inverse LGAD (iLGAD) technology has been proposed by IMB-CNM to enhance the fill factor and provide excellent tracking capabilities. In this work, we explore the use of iLGAD sensors for surface damage irradiation by developing a new generation of iLGADs, the periphery of which is optimized to improve the performance of irradiated sensors. The fabricated iLGAD sensors exhibit good electrical performances before and after X-ray irradiation.