Tengfei Li
Research Subjects
Tengfei Li has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Feng Wei
State Key Laboratory of Advanced Materials for Intelligent Sensing, GRINM Group Co., Ltd., Beijing 100088, China
1 shared publication - Gangrong Li
GRINM (Guangdong) Institute for Advanced Materials and Technology, Foshan 528051, China
1 shared publication - Han Xiao
School of Chemical Engineering, Guizhou Minzu University, Guiyang 550025, China
1 shared publication - Qianhui Wei
State Key Laboratory of Advanced Materials for Smart Sensing, General Research Institute for Nonferrous Metals, Beijing 101402, China
1 shared publication - Qingxi Jin
State Key Laboratory of Advanced Materials for Smart Sensing, GRINM Group Co., Ltd., Beijing 100088, China
1 shared publication - Qingzhu Zhang
School of Advanced Interdisciplinary Sciences, University of Chinese Academy of Sciences, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 2 February 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (3) , 604
Polyethylene Glycol Functionalized Silicon Nanowire Field-Effect Transistor Biosensor for Glucose Detection
Accurate monitoring of blood glucose levels is crucial for the diagnosis of diabetes patients. In this paper, we proposed a simple “mixed-catalyzer layer” modified silicon nanowire field-effect transistor biosensor that enabled direct detection of glucose with low-charge in high ionic strength solutions. A stable screening system was established to overcome Debye screening effect by forming a porous biopolymer layer with polyethylene glycol (PEG) modified on the surface of SiNW. The experimental results show that when the optimal ratio (APTMS:silane-PEG = 2:1) modified the surface of silicon nanowires, glucose oxidase can detect glucose in the concentration range of 10 nM to 10 mM. The sensitivity of the biosensor is calculated to be 0.47 μAcm−2mM−1, its fast response time not exceeding 8 s, and the detection limit is up to 10 nM. This glucose sensor has the advantages of high sensitivity, strong specificity and fast real-time response. Therefore, it has a potential clinical application prospect in disease diagnosis.
- 2 February 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (3) , 604
Open AccessPolyethylene Glycol Functionalized Silicon Nanowire Field-Effect Transistor Biosensor for Glucose Detection
Accurate monitoring of blood glucose levels is crucial for the diagnosis of diabetes patients. In this paper, we proposed a simple “mixed-catalyzer layer” modified silicon nanowire field-effect transistor biosensor that enabled direct detection of glucose with low-charge in high ionic strength solutions. A stable screening system was established to overcome Debye screening effect by forming a porous biopolymer layer with polyethylene glycol (PEG) modified on the surface of SiNW. The experimental results show that when the optimal ratio (APTMS:silane-PEG = 2:1) modified the surface of silicon nanowires, glucose oxidase can detect glucose in the concentration range of 10 nM to 10 mM. The sensitivity of the biosensor is calculated to be 0.47 μAcm−2mM−1, its fast response time not exceeding 8 s, and the detection limit is up to 10 nM. This glucose sensor has the advantages of high sensitivity, strong specificity and fast real-time response. Therefore, it has a potential clinical application prospect in disease diagnosis.