Yash Nayak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yash Nayak has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- David Hilton Ballard
Mallinckrodt Institute of Radiology, Washington University School of Medicine in St. Louis, St. Louis, MO, USA
4 shared publications - Aravinda Ganapathy
School of Medicine, Washington University in St. Louis, St. Louis, MO 63110, USA
3 shared publications - David Chen
D Printing Lab, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA
3 shared publications - Grace L. Bishop
Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA
3 shared publications - Anusha Elumalai
D Printing Lab, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA
2 shared publications - Emily Abdoler
University of Michigan Medical School, Ann Arbor, MI, United States
2 shared publications
Latest Publications
- Open Access
- 7 June 2024
- Published by JMIR Publications Inc. in JMIR Medical Education
- Vol. 10 (1) , e56117
A Use Case for Generative AI in Medical Education
- 7 June 2024
- Published by JMIR Publications Inc. in JMIR Medical Education
- Vol. 10 (1) , e56117
Open AccessA Use Case for Generative AI in Medical Education
- Open Access
- 6 January 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Letter to the Editor: A Use Case for Generative Artificial Intelligence in Medical Education (Preprint)
UNSTRUCTURED No abstract/not applicable
- 6 January 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessLetter to the Editor: A Use Case for Generative Artificial Intelligence in Medical Education (Preprint)
UNSTRUCTURED No abstract/not applicable
- Open Access
Reverse Engineering and 3D Printing of Medical Devices for Drug Delivery and Drug-Embedded Anatomic Implants
In recent years, 3D printing (3DP) has advanced traditional medical treatments. This review explores the fusion of reverse engineering and 3D printing of medical implants, with a specific focus on drug delivery applications. The potential for 3D printing technology to create patient-specific implants and intricate anatomical models is discussed, along with its ability to address challenges in medical treatment. The article summarizes the current landscape, challenges, benefits, and emerging trends of using 3D-printed formulations for medical implantation and drug delivery purposes.
Open AccessReverse Engineering and 3D Printing of Medical Devices for Drug Delivery and Drug-Embedded Anatomic Implants
In recent years, 3D printing (3DP) has advanced traditional medical treatments. This review explores the fusion of reverse engineering and 3D printing of medical implants, with a specific focus on drug delivery applications. The potential for 3D printing technology to create patient-specific implants and intricate anatomical models is discussed, along with its ability to address challenges in medical treatment. The article summarizes the current landscape, challenges, benefits, and emerging trends of using 3D-printed formulations for medical implantation and drug delivery purposes.
- Open Access
- 14 October 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (10) , 1928
Computed Tomography Attenuation of Three-Dimensional (3D) Printing Materials—Depository to Aid in Constructing 3D-Printed Phantoms
Three-dimensionally printed phantoms are increasingly used in medical imaging and research due to their cost-effectiveness and customizability, offering valuable alternatives to commercial phantoms. The purpose of this study was to assess the computed tomography (CT) attenuation characteristics of 27 resin materials from Formlabs, a 3D printing equipment and materials manufacturer. Cube phantoms (both solid and hollow constructions) produced with each resin were subjected to CT scanning under varying tube current–time products with attenuation measurements recorded in Hounsfield units (HU). The resins exhibited a wide range of attenuation values (−3.33 to 2666.27 HU), closely mimicking a range of human tissues, from fluids to dense bone structures. The resins also demonstrated consistent attenuation regardless of changes in the tube current. The CT attenuation analysis of FormLabs resins produced an archive of radiological imaging characteristics of photopolymers that can be utilized to construct more accurate tissue mimicking medical phantoms and improve the evaluation of imaging device performance.
- 14 October 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (10) , 1928
Open AccessComputed Tomography Attenuation of Three-Dimensional (3D) Printing Materials—Depository to Aid in Constructing 3D-Printed Phantoms
Three-dimensionally printed phantoms are increasingly used in medical imaging and research due to their cost-effectiveness and customizability, offering valuable alternatives to commercial phantoms. The purpose of this study was to assess the computed tomography (CT) attenuation characteristics of 27 resin materials from Formlabs, a 3D printing equipment and materials manufacturer. Cube phantoms (both solid and hollow constructions) produced with each resin were subjected to CT scanning under varying tube current–time products with attenuation measurements recorded in Hounsfield units (HU). The resins exhibited a wide range of attenuation values (−3.33 to 2666.27 HU), closely mimicking a range of human tissues, from fluids to dense bone structures. The resins also demonstrated consistent attenuation regardless of changes in the tube current. The CT attenuation analysis of FormLabs resins produced an archive of radiological imaging characteristics of photopolymers that can be utilized to construct more accurate tissue mimicking medical phantoms and improve the evaluation of imaging device performance.
- Open Access
- 14 August 2023
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 10 (8) , 347
Analysis of Superficial Subcutaneous Fat Camper’s and Scarpa’s Fascia in a United States Cohort
Together, the Camper’s and Scarpa’s fasciae form the superficial fat layer of the abdominal wall. Though they have clinical and surgical relevance, little is known about their role in body composition across diverse patient populations. This study aimed to determine the relationship between patient characteristics, including sex and body mass index, and the distribution of Camper’s and Scarpa’s fascial layers in the abdominal wall. A total of 458 patients’ abdominal CT examinations were segmented via CoreSlicer 1.0 to determine the surface area of each patient’s Camper’s, Scarpa’s, and visceral fascia layers. The reproducibility of segmentation was corroborated by an inter-rater analysis of segmented data for 20 randomly chosen patients divided between three study investigators. Pearson correlation and Student’s t-test analyses were performed to characterize the relationship between fascia distribution and demographic factors. The ratios of Camper’s fascia, both as a proportion of superficial fat (r = −0.44 and p < 0.0001) and as a proportion of total body fat (r = −0.34 and p < 0.0001), showed statistically significant negative correlations with BMI. In contrast, the ratios of Scarpa’s fascia, both as a proportion of superficial fat (r = 0.44 and p < 0.0001) and as a proportion of total body fat (r = 0.41 and p < 0.0001), exhibited statistically significant positive correlations with BMI. Between sexes, the females had a higher ratio of Scarpa’s facia to total body fat compared to the males (36.9% vs. 31% and p < 0.0001). The ICC values for the visceral fat, Scarpa fascia, and Camper fascia were 0.995, 0.991, and 0.995, respectively, which were all within the ‘almost perfect’ range (ICC = 0.81–1.00). These findings contribute novel insights by revealing that as BMI increases the proportion of Camper’s fascia decreases, while the ratio of Scarpa’s fascia increases. Such insights expand the scope of body composition studies, which typically focus solely on superficial and visceral fat ratios.
- 14 August 2023
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 10 (8) , 347
Open AccessAnalysis of Superficial Subcutaneous Fat Camper’s and Scarpa’s Fascia in a United States Cohort
Together, the Camper’s and Scarpa’s fasciae form the superficial fat layer of the abdominal wall. Though they have clinical and surgical relevance, little is known about their role in body composition across diverse patient populations. This study aimed to determine the relationship between patient characteristics, including sex and body mass index, and the distribution of Camper’s and Scarpa’s fascial layers in the abdominal wall. A total of 458 patients’ abdominal CT examinations were segmented via CoreSlicer 1.0 to determine the surface area of each patient’s Camper’s, Scarpa’s, and visceral fascia layers. The reproducibility of segmentation was corroborated by an inter-rater analysis of segmented data for 20 randomly chosen patients divided between three study investigators. Pearson correlation and Student’s t-test analyses were performed to characterize the relationship between fascia distribution and demographic factors. The ratios of Camper’s fascia, both as a proportion of superficial fat (r = −0.44 and p < 0.0001) and as a proportion of total body fat (r = −0.34 and p < 0.0001), showed statistically significant negative correlations with BMI. In contrast, the ratios of Scarpa’s fascia, both as a proportion of superficial fat (r = 0.44 and p < 0.0001) and as a proportion of total body fat (r = 0.41 and p < 0.0001), exhibited statistically significant positive correlations with BMI. Between sexes, the females had a higher ratio of Scarpa’s facia to total body fat compared to the males (36.9% vs. 31% and p < 0.0001). The ICC values for the visceral fat, Scarpa fascia, and Camper fascia were 0.995, 0.991, and 0.995, respectively, which were all within the ‘almost perfect’ range (ICC = 0.81–1.00). These findings contribute novel insights by revealing that as BMI increases the proportion of Camper’s fascia decreases, while the ratio of Scarpa’s fascia increases. Such insights expand the scope of body composition studies, which typically focus solely on superficial and visceral fat ratios.