Lijuan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lijuan Li has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jinghai Liu
Nano Innovation Institute, Inner Mongolia Key Lab of Carbon Nanomaterials, Inner Mongolia Engineering Research Center of Lithium-Sulfur Battery Energy Storage, College of Chemistry and Materials Science, Inner Mongolia Minzu University, Tongliao, China
1 shared publication - Wenfeng Hai
Inner Mongolia Key Laboratory of Solid State Chemistry for Battery, Inner Mongolia Engineering Research Center of Lithium-Sulfur Battery Energy Storage, College of Chemistry and Materials Science, Inner Mongolia Minzu University, Tongliao, People’s Republic of China
1 shared publication Yang Liu
Inner Mongolia Key Laboratory of Carbon Nanomaterials, Nano Innovation Institute (NII), College of Chemistry and Chemical Engineering, Inner Mongolia Minzu University, Tongliao 028000, China
1 shared publication- Yushuang Liu
Inner Mongolia Key Laboratory of Solid State Chemistry for Battery, Inner Mongolia Engineering Research Center of Lithium-Sulfur Battery Energy Storage, College of Chemistry and Materials Science, Inner Mongolia Minzu University, Tongliao, People’s Republic of China
1 shared publication Zhelin Liu
School of Chemistry and Environmental Engineering, Changchun University of Science and Technology, Changchun 130022, China
1 shared publicationZhiran Chen
Inner Mongolia Key Laboratory of Carbon Nanomaterials, Nano Innovation Institute (NII), College of Chemistry and Chemical Engineering, Inner Mongolia Minzu University, Tongliao 028000, China
1 shared publication
Latest Publications
- 14 December 2022
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 47 (3) , 1563-1572
Phenylboronic acid conjugated poly(3,4-ethylenedioxythiophene) (PEDOT) coated Ag dendrite for electrochemical non-enzymatic glucose sensing
Blood glucose monitoring is the premise and basis of diabetes diagnosis and treatment. Previously, we developed polythiophene modified by phenylboronic acid derivatives for non-enzyme detection of glucose and discussed the effect of the structure of phenylboronic acid on the response to glucose. In this study, we investigated the effect of the surface morphology of phenylboronic acid-modified polythiophene (poly(EDOT-PBA)) on glucose-sensing performance. To this end, we developed a fern leaf-like structured poly(EDOT-PBA) film and discussed the effect of surface morphology of poly(EDOT-PBA) for glucose sensing. The modified electrode surfaces were characterized by X-ray photoelectron spectroscopy, scanning electron microscopy, static water contact angle, and impedance measurements. The specific interaction between PBA and glucose was detected by impedancemetry. The concentration-dependent specific response was observed in glucose solution. The sensitivity was 426.1 Ω mM−1 cm−2 in 0.05–30 mM with a limit of detection of 0.01 mM. The glucose sensor has good selectivity and stability.
- 14 December 2022
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 47 (3) , 1563-1572
Phenylboronic acid conjugated poly(3,4-ethylenedioxythiophene) (PEDOT) coated Ag dendrite for electrochemical non-enzymatic glucose sensing
Blood glucose monitoring is the premise and basis of diabetes diagnosis and treatment. Previously, we developed polythiophene modified by phenylboronic acid derivatives for non-enzyme detection of glucose and discussed the effect of the structure of phenylboronic acid on the response to glucose. In this study, we investigated the effect of the surface morphology of phenylboronic acid-modified polythiophene (poly(EDOT-PBA)) on glucose-sensing performance. To this end, we developed a fern leaf-like structured poly(EDOT-PBA) film and discussed the effect of surface morphology of poly(EDOT-PBA) for glucose sensing. The modified electrode surfaces were characterized by X-ray photoelectron spectroscopy, scanning electron microscopy, static water contact angle, and impedance measurements. The specific interaction between PBA and glucose was detected by impedancemetry. The concentration-dependent specific response was observed in glucose solution. The sensitivity was 426.1 Ω mM−1 cm−2 in 0.05–30 mM with a limit of detection of 0.01 mM. The glucose sensor has good selectivity and stability.