Sally LiArno
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sally LiArno has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Faizan
Dept. of Life and Sports Sciences, Birmingham City University, City South Campus, Westbourne Road, Birmingham, B15 3TN, UK.
1 shared publication Behzad Farshid
Stryker Corporation Mahwah New Jersey USA
1 shared publication- Etienne Cavaignac
Department of Orthopaedic Surgery Clinique Universitaire Du Sport, CHU de Toulouse Toulouse France
1 shared publication - Eugene Jang
Department of Orthopaedic Surgery, Columbia University Medical Center, New York, NY
1 shared publication - Geoffrey H. Westrich
Hospital for Special Surgery New York City New York USA
1 shared publication - Harold I. Salmons
Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
1 shared publication
Latest Publications
- 23 August 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (9) , e70266
Comparative Wear Behavior of Titanium Nitride‐Coated Titanium and Cobalt Chromium Femoral Components in Cementless Total Knee Arthroplasty
Femoral component surface roughness is a critical determinant of polyethylene wear in total knee arthroplasty (TKA). Titanium nitride (TiN) ceramic surface coatings have been developed to improve wear resistance and address concerns related to metal hypersensitivity; however, comprehensive wear data remain limited. This knee simulator study evaluated the performance of TiN‐coated titanium alloy (6 wt% aluminum, 4 wt% vanadium, balance titanium, Ti‐6Al‐4V) substrate femoral components compared with cobalt chromium (CoCr) femoral components. Mode I wear testing was conducted for 5.0 million cycles (mc) using highly crosslinked polyethylene tibial inserts, with wear rates and polyethylene debris morphology quantified. Mode III third‐body abrasive wear testing was performed on TiN‐coated femoral components using embedded 500 µm TiN‐coated particles for 3.0 mc. Surface roughness was measured using White Light Interferometry (arithmetic mean height, Sa), and surface integrity was assessed using scanning electron microscopy. Following 5.0 mc of Mode I wear, volumetric wear rates were equivalent between TiN‐coated and CoCr femoral components (1.03 vs 1.04 mm 3 /million cycles; p = 0.001), with no notable differences in polyethylene particle size ( p = 0.114) or morphology. During third‐body testing, surface scratching of the TiN coating was observed without evidence of gross surface failure. As anticipated, the mean Sa of TiN‐coated femoral components increased through 3.0 mc of Mode III third‐body testing, while remaining lower than literature‐reported retrieved CoCr values ( p = 0.001). In conclusion, TiN‐coated femoral components demonstrated comparable in vitro adhesive wear performance to CoCr and provided improved resistance to abrasive conditions, where long‐term resistance to abrasion is expected to govern reduced wear.
- 23 August 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (9) , e70266
Comparative Wear Behavior of Titanium Nitride‐Coated Titanium and Cobalt Chromium Femoral Components in Cementless Total Knee Arthroplasty
Femoral component surface roughness is a critical determinant of polyethylene wear in total knee arthroplasty (TKA). Titanium nitride (TiN) ceramic surface coatings have been developed to improve wear resistance and address concerns related to metal hypersensitivity; however, comprehensive wear data remain limited. This knee simulator study evaluated the performance of TiN‐coated titanium alloy (6 wt% aluminum, 4 wt% vanadium, balance titanium, Ti‐6Al‐4V) substrate femoral components compared with cobalt chromium (CoCr) femoral components. Mode I wear testing was conducted for 5.0 million cycles (mc) using highly crosslinked polyethylene tibial inserts, with wear rates and polyethylene debris morphology quantified. Mode III third‐body abrasive wear testing was performed on TiN‐coated femoral components using embedded 500 µm TiN‐coated particles for 3.0 mc. Surface roughness was measured using White Light Interferometry (arithmetic mean height, Sa), and surface integrity was assessed using scanning electron microscopy. Following 5.0 mc of Mode I wear, volumetric wear rates were equivalent between TiN‐coated and CoCr femoral components (1.03 vs 1.04 mm 3 /million cycles; p = 0.001), with no notable differences in polyethylene particle size ( p = 0.114) or morphology. During third‐body testing, surface scratching of the TiN coating was observed without evidence of gross surface failure. As anticipated, the mean Sa of TiN‐coated femoral components increased through 3.0 mc of Mode III third‐body testing, while remaining lower than literature‐reported retrieved CoCr values ( p = 0.001). In conclusion, TiN‐coated femoral components demonstrated comparable in vitro adhesive wear performance to CoCr and provided improved resistance to abrasive conditions, where long‐term resistance to abrasion is expected to govern reduced wear.
- 20 September 2019
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 101 (23) , e125
Accuracy of Reference Axes for Femoral Component Rotation in Total Knee Arthroplasty
Background: Many reference axes are used to evaluate rotation of the femoral component during total knee arthroplasty, including the Whiteside line, surgical transepicondylar axis (sTEA), anatomical transepicondylar axis (aTEA), posterior condylar axis externally rotated 3° (PCA+3°ER), sulcus line, and femoral transverse axis (FTA). There is no consensus about which of these axes is most accurate. Methods: The Stryker Orthopaedic Modeling and Analytics (SOMA) database was used to identify 2,128 entire-femur computed tomography (CT) scans. The Whiteside line, aTEA, PCA+3°ER, sulcus line, and FTA were constructed according to published guidelines. Every axis was compared with the sTEA, which is widely regarded as the gold standard reference axis for rotation of the distal part of the femur but has low intraobserver and interobserver reliability intraoperatively. Results: The PCA+3°ER differed from the sTEA by a mean (and standard deviation) of 0.60° ± 1.64°; it was the most accurate but also had the highest degree of intersubject variability. The mean PCA-sTEA angle was 2.40°, close to the accepted “rule of thumb” of 3°. This value was significantly higher in women (2.64° ± 1.74°) than in men (2.18° ± 1.52°; p < 0.001). The Whiteside line differed from the sTEA by a mean of 1.90° ± 1.38°, and the sulcus line differed from the sTEA by a mean of 1.94° ± 1.49°; neither of these values varied significantly with sex or ethnicity. The FTA differed from the sTEA by a mean of 2.04° ± 1.50°. Least accurate was the aTEA, which differed from the sTEA by a mean of 2.05° ± 1.33°. The combination of 3 axes that are readily available intraoperatively (the Whiteside line, aTEA, and PCA+3°ER) differed from the sTEA by a mean of 1.80° ± 0.70°. Conclusions: In the largest study of its kind, analysis of CT scans of 2,128 femora revealed that no 1 axis could serve as a marker of femoral component rotation with both high accuracy and low variability. Utilizing a combination of 3 methods (PCA+3°ER, the Whiteside or sulcus line, and aTEA) to maximize accuracy and sex and ethnic generalizability when positioning the femoral component is recommended. Clinical Relevance: A large-scale study using a CT-based biomorphometric database demonstrated that use of a combination of 3 axes (PCA+3°ER, the Whiteside or sulcus line, and aTEA) was the optimal strategy for judging femoral component rotation.
- 20 September 2019
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 101 (23) , e125
Accuracy of Reference Axes for Femoral Component Rotation in Total Knee Arthroplasty
Background: Many reference axes are used to evaluate rotation of the femoral component during total knee arthroplasty, including the Whiteside line, surgical transepicondylar axis (sTEA), anatomical transepicondylar axis (aTEA), posterior condylar axis externally rotated 3° (PCA+3°ER), sulcus line, and femoral transverse axis (FTA). There is no consensus about which of these axes is most accurate. Methods: The Stryker Orthopaedic Modeling and Analytics (SOMA) database was used to identify 2,128 entire-femur computed tomography (CT) scans. The Whiteside line, aTEA, PCA+3°ER, sulcus line, and FTA were constructed according to published guidelines. Every axis was compared with the sTEA, which is widely regarded as the gold standard reference axis for rotation of the distal part of the femur but has low intraobserver and interobserver reliability intraoperatively. Results: The PCA+3°ER differed from the sTEA by a mean (and standard deviation) of 0.60° ± 1.64°; it was the most accurate but also had the highest degree of intersubject variability. The mean PCA-sTEA angle was 2.40°, close to the accepted “rule of thumb” of 3°. This value was significantly higher in women (2.64° ± 1.74°) than in men (2.18° ± 1.52°; p < 0.001). The Whiteside line differed from the sTEA by a mean of 1.90° ± 1.38°, and the sulcus line differed from the sTEA by a mean of 1.94° ± 1.49°; neither of these values varied significantly with sex or ethnicity. The FTA differed from the sTEA by a mean of 2.04° ± 1.50°. Least accurate was the aTEA, which differed from the sTEA by a mean of 2.05° ± 1.33°. The combination of 3 axes that are readily available intraoperatively (the Whiteside line, aTEA, and PCA+3°ER) differed from the sTEA by a mean of 1.80° ± 0.70°. Conclusions: In the largest study of its kind, analysis of CT scans of 2,128 femora revealed that no 1 axis could serve as a marker of femoral component rotation with both high accuracy and low variability. Utilizing a combination of 3 methods (PCA+3°ER, the Whiteside or sulcus line, and aTEA) to maximize accuracy and sex and ethnic generalizability when positioning the femoral component is recommended. Clinical Relevance: A large-scale study using a CT-based biomorphometric database demonstrated that use of a combination of 3 axes (PCA+3°ER, the Whiteside or sulcus line, and aTEA) was the optimal strategy for judging femoral component rotation.
- 1 July 2018
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 100-B (7) , 839-844
Which factors influence proximal femoral asymmetry?
Aims: In patients where the proximal femur shows gross deformity due to degenerative changes or fracture, the contralateral femur is often used to perform preoperative templating for hip arthroplasty. However, femurs may not be symmetrical: the aim of this study was to determine the degree of variation between hips in healthy individuals and to determine whether it is affected by demographic parameters. Materials and Methods: CT-scan based modelling was used to examine the pelvis and bilateral femurs of 345 patients (211 males, 134 women; mean age 62 years (standard deviation (sd) 17), mean body mass index 27 kg/m2 (sd 5)) representing a range of ethnicities. The femoral neck-shaft angle (NSA), femoral offset (FO), femoral neck version (FNV), femoral length (FL), femoral canal flare index (fCFI), and femoral head radius (FHr) were then determined for each patient. All measurements were constructed using algorithm-calculated landmarks, resulting in reproducible and consistent constructs for each specimen. We then analyzed femoral symmetry based on absolute differences (AD) and percentage asymmetry (%AS) following a previously validated method. Results: We found an asymmetry > 2% for NSA (mean AD 2.9°, mean %AS 2.3; p = 0.03), FO (AD 3.8 mm, %AS 9.1 ; p = 0.01), FNV (AD 5.1°, %AS 46.7 ; p = 0.001) and fCFI (AD 0.2 mm, %AS 5.4 ; p = 0.7). Significant relationships were found for AD regarding NSA and ethnicity (p = 0.037), FL and height (R2 = 0.22), and fCFI and gender (R2 = 0.34). Conclusion: Our data confirm the presence of asymmetry of proximal femurs, which is mostly independent of demographic parameters. In cases where contralateral templating is used, such asymmetry may lead to inaccurate anatomical restoration of the hip if the templated sizes are routinely implanted. However, the clinical impact cannot be determined from our investigation. Cite this article: Bone Joint J 2018;100-B:839–44.
- 1 July 2018
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 100-B (7) , 839-844
Which factors influence proximal femoral asymmetry?
Aims: In patients where the proximal femur shows gross deformity due to degenerative changes or fracture, the contralateral femur is often used to perform preoperative templating for hip arthroplasty. However, femurs may not be symmetrical: the aim of this study was to determine the degree of variation between hips in healthy individuals and to determine whether it is affected by demographic parameters. Materials and Methods: CT-scan based modelling was used to examine the pelvis and bilateral femurs of 345 patients (211 males, 134 women; mean age 62 years (standard deviation (sd) 17), mean body mass index 27 kg/m2 (sd 5)) representing a range of ethnicities. The femoral neck-shaft angle (NSA), femoral offset (FO), femoral neck version (FNV), femoral length (FL), femoral canal flare index (fCFI), and femoral head radius (FHr) were then determined for each patient. All measurements were constructed using algorithm-calculated landmarks, resulting in reproducible and consistent constructs for each specimen. We then analyzed femoral symmetry based on absolute differences (AD) and percentage asymmetry (%AS) following a previously validated method. Results: We found an asymmetry > 2% for NSA (mean AD 2.9°, mean %AS 2.3; p = 0.03), FO (AD 3.8 mm, %AS 9.1 ; p = 0.01), FNV (AD 5.1°, %AS 46.7 ; p = 0.001) and fCFI (AD 0.2 mm, %AS 5.4 ; p = 0.7). Significant relationships were found for AD regarding NSA and ethnicity (p = 0.037), FL and height (R2 = 0.22), and fCFI and gender (R2 = 0.34). Conclusion: Our data confirm the presence of asymmetry of proximal femurs, which is mostly independent of demographic parameters. In cases where contralateral templating is used, such asymmetry may lead to inaccurate anatomical restoration of the hip if the templated sizes are routinely implanted. However, the clinical impact cannot be determined from our investigation. Cite this article: Bone Joint J 2018;100-B:839–44.