Types
Company, Funder
Locations
Kalamazoo, United States

Latest Publications

  • Open Access

    Correction: Robotic-arm assistance in revision total hip arthroplasty improves the accuracy of acetabular component positioning: a cadaver-based study

    by Kailey Fitzgerald, Ilya Borukhov, Varun Chandra, Chase Smitterberg, Michael A. Mont, Sally LiArno

  • Comparative Wear Behavior of Titanium Nitride‐Coated Titanium and Cobalt Chromium Femoral Components in Cementless Total Knee Arthroplasty

    by Harold I. Salmons, Kailey Fitzgerald, Sally LiArno, Behzad Farshid, Geoffrey H. Westrich

    Femoral component surface roughness is a critical determinant of polyethylene wear in total knee arthroplasty (TKA). Titanium nitride (TiN) ceramic surface coatings have been developed to improve wear resistance and address concerns related to metal hypersensitivity; however, comprehensive wear data remain limited. This knee simulator study evaluated the performance of TiN‐coated titanium alloy (6 wt% aluminum, 4 wt% vanadium, balance titanium, Ti‐6Al‐4V) substrate femoral components compared with cobalt chromium (CoCr) femoral components. Mode I wear testing was conducted for 5.0 million cycles (mc) using highly crosslinked polyethylene tibial inserts, with wear rates and polyethylene debris morphology quantified. Mode III third‐body abrasive wear testing was performed on TiN‐coated femoral components using embedded 500 µm TiN‐coated particles for 3.0 mc. Surface roughness was measured using White Light Interferometry (arithmetic mean height, Sa), and surface integrity was assessed using scanning electron microscopy. Following 5.0 mc of Mode I wear, volumetric wear rates were equivalent between TiN‐coated and CoCr femoral components (1.03 vs 1.04 mm 3 /million cycles; p = 0.001), with no notable differences in polyethylene particle size ( p = 0.114) or morphology. During third‐body testing, surface scratching of the TiN coating was observed without evidence of gross surface failure. As anticipated, the mean Sa of TiN‐coated femoral components increased through 3.0 mc of Mode III third‐body testing, while remaining lower than literature‐reported retrieved CoCr values ( p = 0.001). In conclusion, TiN‐coated femoral components demonstrated comparable in vitro adhesive wear performance to CoCr and provided improved resistance to abrasive conditions, where long‐term resistance to abrasion is expected to govern reduced wear.

  • Open Access

    Early surgeon experience with a fracture-specific humeral stem for proximal humerus fractures: a multicenter survey of predominantly reverse shoulder arthroplasty cases with an illustrative case

    by Matthias Regling, You Yang, Arthur de Gast, Gary F. Updegrove

    Background: Shoulder arthroplasty has become an established treatment option for displaced and complex proximal humeral fractures, particularly in elderly patients. Fracture-specific stems are increasingly used in clinical practice; however, early data on surgeon experience with newly introduced convertible stem designs remain limited. This study aimed to assess orthopedic surgeons’ early intraoperative experience with a newly developed humeral fracture system (Tornier Perform Humeral System – Fracture, Tornier Inc., a wholly owned subsidiary of Stryker, Bloomington, MN, USA) using a structured survey as part of an early product surveillance program. Methods: A prospective observational survey was conducted among orthopedic surgeons in the United States and Canada who had performed surgery using the fracture stem. Case-level evaluations of intraoperative handling, technical features, and surgeon-reported comparisons with routinely used implant systems were collected. Descriptive statistics were used to summarize survey responses. Results: Twenty-six orthopedic surgeons submitted feedback on 47 surgical cases (45 primary cases, 2 revisions), including predominantly reverse configurations (46/47) and one hemiarthroplasty construct. All available stem fixation methods were used: cementless without interlocking screws ( n = 24), cementless with interlocking screws ( n = 14), and cemented ( n = 9). Surgeons reported high levels of satisfaction and favorable ratings for ease of use. Across multiple comparative dimensions, the fracture system was frequently rated favorably compared with surgeons’ routinely used systems. Twenty-five of 26 participating surgeons indicated that they would consider using the system in future cases and would recommend it to others (missing data for one surgeon). Qualitative feedback described perceived benefits related to specific design features, including press-fit capability, bone graft window, proximal stem design, and the option for interlocking screw fixation. Conclusions: Surgeons reported favorable early intraoperative impressions of this fracture system. These findings provide exploratory insights into surgeon-reported usability and perceived design characteristics under early real-world use. Further studies are required to evaluate the clinical relevance of these surgeon-reported perceptions. Level of evidence: IV.

  • Open Access

    Robotic-arm assistance in revision total hip arthroplasty improves the accuracy of acetabular component positioning: a cadaver-based study

    by Kailey Fitzgerald, Ilya Borukhov, Varun Chandra, Chase Smitterberg, Michael A. Mont, Sally LiArno

    Introduction Acetabular component positioning is a key factor for stability, impingement, wear, and biomechanics in revision total hip arthroplasty (THA). However, anatomic distortion and previous implants may complicate positioning. Although evidence on computed-tomography (CT)-based robotic assistance in revision THA is limited, its planning features and precision may improve surgical plan execution. This study aimed to measure the precision and accuracy of acetabular component positioning of revision robotic-arm assisted total hip arthroplasty (RA-THA) compared with a published manual primary total hip arthroplasty (M-THA) benchmark for: (a) acetabular inclination; (b) acetabular version; and (c) center of rotation (COR), with comparison by surgeon case volume. Materials and methods There were seven cadavers (nine hips) that previously underwent primary THA revised with RA-THA by independent surgeons with varying primary RA-THA case volumes, surgical approaches, and acetabular component types. Due to surgical protocol deviations, two hips were excluded leaving seven hips from six cadavers. Pre- and postoperative CT scans were compared to calculate absolute error for inclination, version, and COR; normality was established with the Anderson-Darling test and two-variance tests assessed differences in standard deviations (α = 0.05). Mean differences between cadaver-based revision RA-THA and published M-THA values were compared with Welch's t-test for superiority (α = 0.05). Effect sizes were reported as mean differences with 95% upper bounds and sensitivity analyses were performed given the fixed sample size. Results Revision RA-THA demonstrated significantly greater accuracy for acetabular inclination (2.5 ± 1.9° versus 7.2 ± 3.2°, P = 0.008) and version (2.2 ± 1.6° versus 7.8 ± 4.6°, P = 0.014), and significantly greater precision for acetabular version (P = 0.023) compared with M-THA. There was adirectionally lower error for COR compared with M-THA. Mean error reductions were 5.7° for version and 4.7º for inclination with 95% upper bounds of -1.9 for both version and inclination. Low RA-THA surgical volume corresponded with the highest absolute error for shell inclination (5.5º) and version (5.0º), though values remained below published M-THA averages. Conclusions Revision RA-THA reduced error in both acetabular inclination and acetabular version, and variability in acetabular version relative to the M-THA benchmark. Although these results relate only to technical performance, accurate acetabular positioning in clinical practice is an important factor in reducing the risk of malposition-related complications in revision THA.

  • Open Access

    Incidence of refibrillation and shock-resistant ventricular fibrillation during OHCA when treated with a public access defibrillator: implications for CPR timing in lay rescuer-treated OHCA

    by Amy Kernaghan, Adam Harvey, Hannah Currie, Olibhéar McAlister, Robert Walker, Fred Chapman, David McEneaney, Jennifer Adgey

    Background: Out-of-hospital cardiac arrest (OHCA) treatment often requires multiple defibrillatory shocks due to failed defibrillation or refibrillation. The complete nature of refractory ventricular fibrillation (VF) is unknown, as many studies do not consider shocks delivered by lay rescuers prior to the arrival of basic life support (BLS)/advanced life support (ALS) when quantifying refractory VF. ERC guidelines define refractory VF as continuous VF after three consecutive shocks, not differentiating between patients who refibrillate and those with shock-resistant VF (three consecutive failed shocks) which may contribute to this variation in reported incidence. There are some differences in treatment recommendations for patients who refibrillate and those with shock-resistant VF. Therefore, understanding the number of shocks delivered by lay-rescuers with public access defibrillators (PADs) and the patient’s response to them prior to BLS/ALS arrival may inform treatment strategies. Methods: ECG data collected retrospectively from OHCAs treated by lay-rescuers using PADs were analysed. Cardiac rhythm, shock success, refibrillation, time to refibrillation and presence of shock-resistant VF (three consecutive failed shocks) were determined by two investigators. Results: Data were available for 1459 patients receiving at least one shock. Refibrillation occurred in 498 (34.1%) patients. The median number of refibrillations per patient was 1 (IQR 1, 2). Median time to refibrillation was 29.8 s. Three consecutive shocks were observed in 231 of the 1459 (15.8%) patients, 11 patients (4.8% of 231 patients) had shock-resistant VF. Conclusion: When treated by lay-rescuers with PADs, refibrillation occurrence is lower than that reported for patients treated by BLS/ALS. However, aligned with BLS/ALS studies, in lay-rescuer treated OHCA, refibrillation typically occurs within the first 30 s following a successful shock. Therefore, patients who refibrillate are typically in VF for an additional 1.5 min before receiving a subsequent shock for PADs with a 2 min cardiopulmonary resuscitation (CPR) cycle. This finding emphasises the need for investigation into optimal CPR duration for patients requiring multiple shocks.


  • Open Access

    Robotic-assisted pedicle screw placement achieves high accuracy and narrows the experience gap: a preclinical evaluation

    by Anna T. Reza, Matthias Walper, Mitchell K. Ng, Paul G. Mastrokostas, Andrew S. Lee, Rafael G. de Oliveira, Kornelis A. Poelstra, John K. Ratliff, Rajiv K. Sethi, Michael A. Mont

    To assess a robotic-assisted system versus open manual techniques to: (1) compare pedicle screw accuracy between fellows and attendings with and without robotic assistance, and (2) evaluate executed versus planned trajectory fidelity relative to prior reports. Robotic-assisted spine systems aim to improve the accuracy, reproducibility, and safety of pedicle screw placement. Limited evidence compares outcomes across differing surgeon experience levels. A total of 255 thoracolumbar pedicle screws were placed in synthetic torsos simulating adult degenerative anatomy. Four surgeons (two fellows, two attendings) each placed half their screws using open fluoroscopy-guided techniques and half using a minimally invasive percutaneous approach with the Mako Spine system and intraoperative CT-based planning. Postoperative CT and the Gertzbein-Robbins classification were used to assess accuracy. Optimal placement (Grade A), breach rates, and positional/angular deviation from planned trajectories were recorded. The robotic cohort achieved a higher rate of clinically acceptable screw placement compared with the manual cohort, although this difference was not statistically significant (124/127, 97.6% vs. 120/128, 93.8%; P = 0.223). Fellows and attendings both achieved high clinically acceptable screw placement rates using robotics (63/64, 98.4% vs. 61/63, 96.8%). Among fellows, robotic assistance increased optimal screw placement compared with the manual technique (53/64, 82.8% vs. 41/64, 64.1%; P < 0.05). Robotic screws demonstrated low mean deviations from planned trajectories (1.4 ± 0.9 mm positional, 1.7 ± 1.1° angular). The Mako Spine system enabled precise screw placement and narrowed performance gaps for less experienced surgeons. It shows promise as both training tool and means to standardize outcomes.

  • What is the Best Way to Identify Femoral and Tibial Anatomical Landmarks for Component Alignment? A Cadaver-Based Study

    by Michael A. Mont, Melanie Caba, Azhar Ali, Chase W. Smitterberg, Sean B. Sequeira, James Crutcher, Ormonde Mahoney, Antonia F. Chen

    Femoral and tibial component malalignment in total knee arthroplasty has been associated with postoperative instability, patient dissatisfaction, and early component failure. Precise placement and rotational alignment are therefore critical to achieving optimal clinical results. Femoral and tibial component positioning relies on identification of bony landmarks relative to native anatomy. Previous studies have demonstrated that manual identification of these landmarks is inconsistent; however, few studies have directly compared manual probe identification with computed tomography (CT) measurements. The purpose of this study was to compare variability in femoral and tibial landmark identification using manual probing versus CT-based identification. Femoral and tibial bony landmarks were identified on six cadaver knees by two evaluator groups, including the anterior trochlear groove, intercondylar notch, medial and lateral posterior femoral condyles, medial and lateral epicondyles, tibial tubercle, medial and lateral tibial plateau, and medial and lateral malleoli. The first group consisted of three fellowship-trained arthroplasty surgeons who identified landmarks intraoperatively using a manual probe, whereas the second consisted of three evaluators who identified landmarks digitally on corresponding preoperative CT scans. Each landmark was identified three times with rotation between specimens for randomization, and data were collected using a robotic system. The three-dimensional landmark locations were converted into a distance value, and variation between landmarks was analyzed. A two-sample student t-test was utilized to evaluate statistical significance at p < 0.05. The CT-based identification demonstrated decreased variation than manual probe techniques across all landmarks. Statistically significant reductions in variability were observed for the anterior trochlear groove (p < 0.001), medial posterior femoral condyle (p = 0.010), lateral posterior femoral condyle (p = 0.021), medial epicondyle (p = 0.006), lateral tibial plateau (p = 0.029), and lateral malleolus (p = 0.028). Identification using CT-based techniques of femoral and tibial landmarks demonstrated less variability than manual probing, which may lead to more consistent implant component placement. Further studies are needed to determine the influence of landmark variation on component positioning.

  • Baseline Knowledge of Direct Care Clinicians Regarding the Role of Full-body Support Surfaces in Pressure Injury Prevention

    by Stephanie Slayton, Rachel Moseley, Susan Morello, Marcia Bauman, Carroll Gillespie

    OBJECTIVE: To evaluate direct care clinicians’ understanding of the role of full-body support surfaces in pressure injury prevention. METHODS: A questionnaire was developed and distributed to direct care clinicians through QR code (through flyers and online). A total of 333 surveys were included in the analysis. Survey data were analyzed using both descriptive statistics and a Fisher exact test to compare the answers of respondents who were certified in wound care with those who were not certified. RESULTS: The majority of respondents were nurses (81.68%), but several other disciplines were represented. Of the respondents, 41% had practiced for 21 or more years, and the acute hospital setting was the most common area of practice (70.57%). Of the respondents, 73.87% were certified in wound care through at least one organization. More direct care clinicians who are certified in wound care were aware that testing standards are available for support surfaces as compared with those not certified in wound care (73.17% vs 62.07%). For the knowledge-based questions, the wound care certified clinicians performed better on 7 of the questions than those not certified (questions 1, 2, 4, 5, 6, 7, and 9). Questions 3 and 7 demonstrated low proficiency within both groups. CONCLUSIONS: Based on the survey results, there are several deficits in knowledge demonstrated by direct care clinicians regarding support surface standards and their clinical application for use in pressure injury prevention.

  • Open Access

    Systematic Review of Nonmedical Costs of Firearm Injury

    by David W. Hutton, Taylor W. Lefler, Danwei Yang, Shiying Mai, Michael Holtz, Hanwen Zhang, Honey S. Modi, William B. Hillegass, Marc A. Zimmerman, Patrick M. Carter