BJBaozhen Jia

Baozhen Jia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Baozhen Jia has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Cuiying Zheng

    State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, China Institute of Water Resources and Hydropower Research (IWHR), Beijing 100038, China

    4 shared publications
  • Jinsheng Jia

    State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, China Institute of Water Resources and Hydropower Research (IWHR), Beijing 100038, China

    4 shared publications
  • Yangfeng Wu

    School of Civil Engineering, Beijing Jiaotong University, Beijing 100044, China

    4 shared publications
  • Wambley Adomako Baah

    State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, China Institute of Water Resources and Hydropower Research (IWHR), Beijing 100038, China

    3 shared publications
  • Yang Wang

    State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, China Institute of Water Resources and Hydropower Research (IWHR), Beijing 100038, China

    2 shared publications
  • Yue Wang

    State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, China Institute of Water Resources and Hydropower Research (IWHR), Beijing 100038, China

    2 shared publications

Latest Publications

  • Open Access

    Enhancement of Air-Entrained Grout-Enriched Vibrated Cemented Sand, Gravel and Rock (GECSGR) for Improving Frost and Thawing Resistance in CSGR Dams

    by Wambley Adomako Baah, Jinsheng Jia, Cuiying Zheng, Baozhen Jia, Yue Wang, Yangfeng Wu

    Cemented Sand, Gravel, and Rock (CSGR) dams have traditionally used either Conventional Vibrated Concrete (CVC) or Grout-Enriched Roller Compacted Concrete (GERCC) for protective and seepage control layers in low- to medium-height dams. However, these methods are complex, prone to interference, and uneconomical due to significant differences in the expansion coefficient, elastic modulus, and hydration heat parameters among CSGR, CVC, and GERCC. This complexity complicates quality control during construction, leading to the development of Grout-Enriched Vibrated Cemented Sand, Gravel, and Rock (GECSGR) as an alternative. Despite its potential, GECSGR has limited use due to concerns about freeze–thaw resistance. This project addresses these concerns by developing an air-entrained GECSGR grout formulation and construction technique. The study follows a five-phase approach: mix proportioning of C1806 CSGR; optimization of the grout formulation; determination of grout addition rate; evaluation of small-scale lab samples of GECSGR; and field application. The results indicate that combining 8–12% of 223 kg/m3 cement grout with 2–2.23 kg/m3 of admixtures, mud content of 15%, a marsh time of 26–31 s. and a water/cement ratio of 0.5–0.6 with the C1806 parent CSGR mixture achieved a post-vibration in situ air content of 4–6%, excellent freeze–thaw resistance (F300: mass loss −10 m/s). The development of a 2-in-1 slurry addition and vibration equipment eliminated performance risks and enhanced efficiency in field applications, such as the conversion of the C1804 CSGR mixture into air-entrained GECSGR grade C9015W6F50 for the 2.76 km Qianwei protection dam. Economic analysis revealed that the unit cost of GECSGR production is 18.3% and 6.33% less than CVC and GERCC, respectively, marking a significant advancement in sustainable cement-based composite materials in the dam industry.


  • Open Access

    Optimizing Paste and Mortar Margins (α and β) to Enhance Compressive Strength in Cemented Sand, Gravel and Rock

    by Wambley Adomako Baah, Jinsheng Jia, Cuiying Zheng, Yue Wang, Baozhen Jia, Yangfeng Wu

    A suitable range of paste and mortar margins (α and β) to enhance compressive strength in Rich-Mix cemented sand gravel and rock (CSGR) material for application in CSGRD construction is critical. SL 678-2014 recommends margins > 1, which are specifically designed to fill the voids within the fine and coarse aggregates with paste and mortar, respectively, while allowing some excess for workability. However, the optimum ranges of values after 1 are inadequately determined, often leading to high efforts and time-consuming trial mixes that are not economical. This study evaluates two datasets to identify the optimal ranges of α and β margins for compressive strength development in Rich-Mix CSGR, aiming to achieve the compressive strength class C18020, intended for use as cushion, protective, and seepage control layers in CSGRD. Using Pearson correlations, t-statistics, and p-values, the first dataset (7, 28, 90, and 180 days) showed weak correlations between paste margins and compressive strengths (coefficients 0.172 to 0.418, p-values > 0.05) and negligible relationships for mortar margins (coefficients −0.269 to 0.204, p-values > 0.05), affirming the contribution of other factors in the compressive strength development in CSGR. The second dataset (14, 28, 90, and 180 days) revealed significant positive correlations between paste margins and strengths at 14, 90, and 180 days (coefficients up to 0.850, p-values < 0.05). Mortar margins, however, negatively impacted strength (coefficients −0.544 to −0.628, p-values < 0.05), revealing the need to control the sand ratio. The optimal range of values was 1.05 ≤ α ≤ 1.09 and 1.15 ≤ β ≤ 1.25, with a water–binder ratio of 0.7~1.3, vibrating–compacted value (VC) of 2~8 s, and sand ratio of 18~35%. These findings highlight the significance of precise paste and mortar margin ranges in the compressive strength development of Rich-Mix CSGR.


  • Open Access

    A New Method for Constructing the Protection and Seepage Control Layer for CSGR Dam and Its Application

    by Yangfeng Wu, Jinsheng Jia, Cuiying Zheng, Baozhen Jia, Yang Wang, Wambley Adomako Baah

    Effective seepage control is crucial for maintaining the structural integrity of Cemented Sand, Gravel and Rock (CSGR) dams. Traditional methods using conventional concrete (CVC) or grout-enriched roller-compacted concrete (GERCC) are costly and disruptive. This paper presents a novel technique for constructing the protection and seepage control layer in Cemented Sand, Gravel and Rock (CSGR) dams. The method involves grouting and vibrating the loosened Cemented Sand, Gravel and Rock (CSGR) material to create vibrated grout-enriched Cemented Sand, Gravel and Rock, which performs similarly to concrete. A new surface water stop structure has also been developed for the structural joints. Laboratory tests revealed that Cemented Sand, Gravel and Rock (CSGR) with a vibrating–compacted (VC) value of 2–6 s and a compressive strength of 4 MPa meets design requirements for medium and low dams when the slurry addition rate is 8–12%. The T-shaped surface water stop demonstrated a bonding strength of over 1.8 MPa, withstanding a water pressure of 1.6 MPa. This method, integrated with dam body construction, reduces material costs by about 50% and eliminates construction interference. Specialized equipment for this technique has been developed, with a capacity of 12 m2/h. Implemented in the Minjiang Navigation and Hydropower Qianwei Project and Shaping I Hydropower Station, it has shown significant economic, environmental and safety benefits, promoting sustainable dam construction.


  • Open Access

    Investigation on Hydraulic Fracturing and Flexible Anti-Hydrofracturing Solution for Xiaowan Arch Dam

    by Yangfeng Wu, Jinsheng Jia, Yang Wang, Cuiying Zheng, Lei Zhao, Baozhen Jia

    Understanding hydraulic fracturing in concrete super-high arch dams is vital for the implementation of safety measures on the bearing surface. In this study, we conducted tests on hydraulic fracturing for the Xiaowan arch dam (294.5 m) to analyze concrete behavior at cracks under various stress conditions. The risk of hydraulic fracturing near the dam heel was identified without compressive stress. Addressing this, we propose a flexible anti-hydrofracturing system using GB sealing material and a spray polyurea coating. Simulation tests on three schemes: ‘3 mm GB plate + 4 mm polyurea’, ‘1 mm GB glue + 5 mm polyurea’, and ‘7 mm polyurea’ showed effective prevention of hydrofracturing at concrete crack openings of 5 mm, 8 mm, or 10 mm under 300 m water pressure. Field tests supported ‘3 mm GB plate + 4 mm polyurea’ and ‘7 mm polyurea’ as optimal solutions for dam sections. Implementation involves a protective block layout with ‘3 mm GB plate + 4 mm polyurea’ on blocks and ‘7 mm polyurea’ in interval zones and corners. Since 2008, maximum leakage, including rock foundation, has remained minimal at 2.78 L/s under regular water levels. These insights aid similar concrete dams in optimizing safety systems.