Zhaoqiang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhaoqiang Zhang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Arne Nysveen
Department of Electric Energy, Norwegian University of Science and Technology, Trondheim, Norway
3 shared publications - Hossein Ehya
Department of Electric Energy, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
2 shared publications Robert Nilssen
Department of Electric Power Engineering, Norwegian University Science and Technology, Trondheim, Norway
2 shared publicationsAnyuan Chen
Norwegian Univ Sci & Technol, Dept Elect Energy, N-7491 Trondheim, Norway
1 shared publicationBørge Johannes Fagemyr
Norwegian Univ Sci & Technol, Dept Elect Energy, N-7491 Trondheim, Norway
1 shared publicationBørge Johannes Fagermyr
Department of Electric Power Engineering, Norwegian University Science and Technology, Trondheim, Norway
1 shared publication
Latest Publications
- 2 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 6045-6055
Virtual-Stator Loss Model for Synchronous Generators With Fractional-Slot Winding
In synchronous generators, the end-region field can cause additional losses at clamping structures and stator end core. It can be a computational challenge to solve the end-region field of synchronous generators featuring fractional-slot winding. With a minor modification of the number of stator slots, the winding scheme can be changed to the integral slot and, consequently, a virtual stator is derived. The model size of a three-dimensional (3D) Virtual-stator Loss Model (VLM) is much smaller than the Real-stator Loss Model (RLM), and the computational burden is substantially alleviated. This paper delves into the theory underpinning VLM and its practical implementation. From the perspective of two-dimensional (2D) analysis, 2D VLM demonstrates close results in field analysis and loss computation when compared to 2D RLM, indicating the potential of the 3D VLM in accurately computing end-region losses. The 3D VLM is used to compute the end-region losses at different operating points. It concludes that the 3D VLM can keep the essential nature of the loss-producing mechanism while dramatically mitigating the computation hurdles. Lab tests at a 100 kVA salient-pole synchronous generator prove that the investigation approach employed in the paper is trustworthy.
- 2 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 6045-6055
Virtual-Stator Loss Model for Synchronous Generators With Fractional-Slot Winding
In synchronous generators, the end-region field can cause additional losses at clamping structures and stator end core. It can be a computational challenge to solve the end-region field of synchronous generators featuring fractional-slot winding. With a minor modification of the number of stator slots, the winding scheme can be changed to the integral slot and, consequently, a virtual stator is derived. The model size of a three-dimensional (3D) Virtual-stator Loss Model (VLM) is much smaller than the Real-stator Loss Model (RLM), and the computational burden is substantially alleviated. This paper delves into the theory underpinning VLM and its practical implementation. From the perspective of two-dimensional (2D) analysis, 2D VLM demonstrates close results in field analysis and loss computation when compared to 2D RLM, indicating the potential of the 3D VLM in accurately computing end-region losses. The 3D VLM is used to compute the end-region losses at different operating points. It concludes that the 3D VLM can keep the essential nature of the loss-producing mechanism while dramatically mitigating the computation hurdles. Lab tests at a 100 kVA salient-pole synchronous generator prove that the investigation approach employed in the paper is trustworthy.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-10
Material Characterization and Stator Core Loss Computation of Synchronous Generators with Stacking Force Accounted
In electrical machines, electrical steels are stacked together with forces to maintain mechanical rigidity. This stacking force alters the magnetic properties of laminated steel and consequently changes its loss behavior. Failing to consider the stacking force can lead to increased errors in core loss computation. This paper investigates the impact of stacking force on the stator core loss of synchronous generators. Magnetic properties (magnetization and loss) of the electrical steel M400- 50A are measured in a special-designed ring core test, and during the test, the ring core is subjected to normal pressing force controlled in closed loop. This test reveals that stacking stress reduces permeability and results in more specific loss for a given flux density. Furthermore, it demonstrates that the weakening of magnetic properties is nonlinearly correlated with the applied stress. Two core loss models are used to compute the stator core loss of a 100 kVA synchronous generator. Lab tests conducted on this generator demonstrate a noticeable improvement in computational accuracy when the stacking force is considered. Among the two core loss models, the two-component frequency domain Bertotti method requires less implementation effort and yields better accuracy.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-10
Material Characterization and Stator Core Loss Computation of Synchronous Generators with Stacking Force Accounted
In electrical machines, electrical steels are stacked together with forces to maintain mechanical rigidity. This stacking force alters the magnetic properties of laminated steel and consequently changes its loss behavior. Failing to consider the stacking force can lead to increased errors in core loss computation. This paper investigates the impact of stacking force on the stator core loss of synchronous generators. Magnetic properties (magnetization and loss) of the electrical steel M400- 50A are measured in a special-designed ring core test, and during the test, the ring core is subjected to normal pressing force controlled in closed loop. This test reveals that stacking stress reduces permeability and results in more specific loss for a given flux density. Furthermore, it demonstrates that the weakening of magnetic properties is nonlinearly correlated with the applied stress. Two core loss models are used to compute the stator core loss of a 100 kVA synchronous generator. Lab tests conducted on this generator demonstrate a noticeable improvement in computational accuracy when the stacking force is considered. Among the two core loss models, the two-component frequency domain Bertotti method requires less implementation effort and yields better accuracy.
- 16 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (3) , 1-4
Computation of Core Losses in Electrical Steel Laminations With Impacts of Normal Flux and PWM Switching Considered
Normal flux (perpendicular to the lamination plane) and pulse width modulation (PWM) can have significant impacts on the losses of steel laminations, e.g. in converter-fed synchronous machines or transformers. This paper proposes a model for computing the losses of steel laminations with the impacts of normal flux and PWM switching considered. The total core losses are computed by modifying the core losses of a reference sinusoidal case with the global statistics about supply voltage. A dedicated test setup was developed to validate the loss model. The measurement shows that the proposed model can compute core losses with acceptable accuracy, reasonable computing time, and moderate demand for computing resources.
- 16 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (3) , 1-4
Computation of Core Losses in Electrical Steel Laminations With Impacts of Normal Flux and PWM Switching Considered
Normal flux (perpendicular to the lamination plane) and pulse width modulation (PWM) can have significant impacts on the losses of steel laminations, e.g. in converter-fed synchronous machines or transformers. This paper proposes a model for computing the losses of steel laminations with the impacts of normal flux and PWM switching considered. The total core losses are computed by modifying the core losses of a reference sinusoidal case with the global statistics about supply voltage. A dedicated test setup was developed to validate the loss model. The measurement shows that the proposed model can compute core losses with acceptable accuracy, reasonable computing time, and moderate demand for computing resources.