Giovanni Gardan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Rare Earth Element Recycling from Energy-Transition E-Waste: A Review of Thermal and Electrothermal Processes

    by Giovanni Gardan, Giulio Poggiana, Francesco Lucchini, Fabrizio Dughiero, Riccardo Torchio


  • Experimental Validation of Multiconductor Cell Analysis by Overhead Line Field Measurements

    by Francesco Sanniti, Sebastian Dambone Sessa, Giovanni Gardan, Luca Rusalen, Roberto Benato, Luciano Minto, Gilberto Ricci, Michele Schiavinato, Fabio Trombini

    Multiconductor Cell Analysis (MCA) is a matrix algorithm computing the electrical steady-state regime of any asymmetrical multiconductor system. This paper presents two experimental validations of MCA, which are carried out by two measurement campaigns performed in two different areas of Italy: on the Extra High Voltage (EHV) double-circuit OverHead Line (OHL) Dolo-Venezia Nord (18 km long) and on Suvereto-Montalto di Castro (120 km long) EHV OHL. By considering the double-circuit configuration of these lines, it has been assessed the impact of one inducing circuit, kept in service, on the other circuit, kept out of service, for the evaluation of induced voltages and currents. The induced circuit experiences induced voltage magnitudes ranging from about 4 kV to 30 kV when it is open at both ends, whereas the induced voltages are negligible but the current magnitudes ranging from 10 A to 28 A when it is grounded at both ends. The maximum mismatch between measurements and MCA results is 8,6% of the induced voltage magnitude of the phase closest to the earth. This mismatch is theoretically explainable by considering that this phase is the more subjected to the presence of unknown proximity objects along the route which could alter the electric field. One more time, comparisons between computations and measurements confirm the very good agreement between MCA and the physical behavior of asymmetric multiconductor systems.


  • Open Access

    Assessing the Static Security of the Italian Grid by Means of the N-1 Three-Phase Contingency Analysis

    by Giovanni Gardan, Luca Rusalen, Roberto Benato

    The ongoing replacement of synchronous machine generators (SMs) with converter-interface generators (CIGs) is raising the voltage unbalance of power systems, affecting power quality and grid stability. This paper focuses on a key power quality index for power systems, i.e., the voltage unbalance factor. The purpose of this work is twofold. First, it presents the generalization of a three-phase power flow algorithm developed by University of Padova, named PFPD_3P, to assess the voltage unbalance factors of power systems supplied by CIGs. In particular, it is demonstrated that CIGs can be modelled as three-phase PV/PQ constraints embedding their positive-, negative- and zero-sequence admittances. Then, the concept of three-phase contingency analysis is introduced. Indeed, for static security evaluation, the classical single-phase contingency analysis may no longer be sufficient, as it lacks power quality computations, e.g., voltage/current unbalance factors. Numerical simulations evaluating the unbalance factors due to different generation mix scenarios and contingencies are tested on the Italian extra-high-voltage/high-voltage (EHV/HV) grid. The choice of this network relies on its representativeness, as CIGs are the majority of new installations in the Italian generation mix.


  • Open Access

    AC ripple on DC voltage: Experimental and theoretical investigation of the impact on accelerated ageing in electrical insulation

    by Giovanni Gardan, Gian Carlo Montanari

    With the increasing penetration of DC systems into the high voltage and medium voltage power industry, DC voltage is becoming common for distribution/transmission and to supply different typologies of loads. The allowable extent of AC ripple superimposed to DC, and its effect on insulation ageing, is a long‐term discussed topic. The most harmful phenomenon causing extrinsic ageing acceleration and insulation system premature failure is partial discharges (PD); thus, the risk of incepting PD due to AC ripple could become a primary issue for electrical asset equipment reliability. In this work, the impact of AC sinusoidal ripple on insulation system life and reliability is dealt with, considering both intrinsic and extrinsic ageing but focusing on the latter, that is, the PD aspect. Experiments are performed to assess how the jump voltage (due to AC ripple) and the DC component impact on PD activity in terms of amplitude and repetition rate. For the first time, the correlation between the magnitude of jump voltage associated with ripple and PD inception is established, shedding a light on the allowable ripple extent which does not impact significantly on ageing and premature insulation failure. This approach can provide straightforward tools for design specification and ageing inference of insulation systems.


  • Application to the Italian AC/DC EHV Network of the Paduan Three-phase Power Flow (PFPD_3P)

    by Luca Rusalen, Giovanni Gardan, Roberto Benato

    The HVDC tie lines represent a growing solution for the transmission system operators in order to dispatch the renewable source plant production on long distances. In the Italian transmission network, there are currently five HVDC links and other two are planned ( i.e. , Tyrrhenian Link and Adriatic Link). In this paper the matrix algorithm PFPD_3P is generalized in order to assess the power quality of real and large AC/DC transmission networks. The method is applied to study the voltage unbalance in two case studies: a 76-busbar network, and the Italian AC/DC HV/EHV network. In order to validate the method, solution comparisons with the commercial software DIgSILENT PowerFactoy are performed for both case studies showing a good agreement. The HVDC-VSC/LCC links are modelled as PV/PQ constraints at the positive sequence, which represent both the AC and DC behavior of the HVDC links. Since three-phase power flow is fundamental to compute network power quality, converter zero/negative sequence circuit is considered for both VSC and LCC.


  • Open Access

    Dynamic Power Flow Modeling Primary and Secondary Frequency Regulations

    by Roberto Benato, Giovanni Gardan, Francesco Sanniti

    In power systems, the steady-state operations following any disturbance can be assessed by means of time-domain simulations, which consider the dynamic of the system without simplifying hypotheses. This paper proposes a formulation of the power flow problem with distributed slack bus model able to determine the steady-state impact on frequency and generation set-points of primary and secondary frequency regulation. This is done by deriving the real power balance expressions (including power losses, primary/secondary regulation, and the real frequency deviation) before and after the occurrence of any event or disturbance. This is achieved without resorting to the solution of a time-domain simulation. The performance of the proposed formulation is discussed through the standard WSCC 9-bus system and a 102-bus model of the Sicilian grid. Solutions are compared with those obtained with conventional time-domain simulations.

  • Open Access

    Investigating Optimal Approaches for Energizations of DC Systems: The Stepwise Technique

    by Giovanni Gardan, Gian Carlo Montanari

    The increasing presence of HVDC (High Voltage Direct Current) links and MVDC (Medium Voltage Direct Current) connections in transmission networks needs an in-depth knowledge of the mechanisms that could affect life and reliability of electrical asset components. As for all electrical systems in general, a crucial factor affecting availability of a HVDC asset is the insulation system reliability. One of the most common causes of premature electrical failure of asset components is electrical insulation breakdown or loss of serviceability. MV/HV extrinsic accelerated aging of organic insulation is mainly due to partial discharges (PD). Their presence, even if not promoting immediate breakdown, is almost a certain cause of apparatus life not matching specifications. This paper focuses on energizations on HVDC insulation systems, and, in general, supply voltage variations, which could be affected by PD due to manufacturing, laying, interface, or structural defects (as butt gaps). To minimize PD inception risk, a theory-driven, stepwise voltage application concept is proposed. The basic idea arises from the consideration that the factor playing a key role in PD inception is the jump voltage, and the electric field distribution in insulation during voltage transients is driven by permittivity (capacitance). Thus, energizing an insulation system with a first step lower than the partial discharge inception voltage in AC ( PDIVAC ) and then growing voltage by smaller steps minimizing jump voltage would allow almost PD-free operation (apart from the risk of low-repetition PD at DC steady state if nominal voltage exceeds PDIVDC ). The effectiveness of this approach is proved by means of tests carried out on a simple test object consisting of flat XLPE (Crossed Linked Polyethylene) specimens with electrodes designed to cause surface PD, having available an innovative PD detection system which performs automatically and effectively both during voltage transients and in DC steady-state conditions. The experimental results show that the stepwise voltage energization, compared to the single step energization, could decrease significantly the number and magnitude of detected PD during energization transients, leading therefore the reduction of one order of magnitude of PD associated energy and relevant damage.


  • Open Access

    Partial Discharge Inception Modelling of Insulating Materials and Systems: Contribution of Electrodes to Electric Field Profile Calculation

    by Giovanni Gardan, Gian Carlo Montanari

    Partial discharge inception modeling is a powerful tool for material investigation and insulation system design in order to achieve the objective of PD-free operation of insulation systems. Model validation, however, requires accurate and repeatable testing conditions, and the aim of this paper is to look at the influence of electrodes and electric field simulation on partial discharge inception model prediction accuracy. Awareness of the geometric electrode configuration is important to forecast both the typology of discharge and the corresponding partial discharge inception voltage value. It is shown, in fact, that inaccurate evaluation of electrode shape (e.g., its flat part and contour) might impact significantly on electric field estimation, the typology of incepted discharges, and, thus, on model accuracy, i.e., on partial discharge inception voltage prediction, which is the basis for the partial discharge-free design of insulating materials and systems. In particular, small electrode curvature radius variations do not significantly affect the PDIV value or PD typology identification. However, worsening electrode/insulation specimen contact can significantly impact PD inception and typology evaluation.


  • Open Access

    A New Algorithm for Multi-Area Power Flow

    by Roberto Benato, Giovanni Gardan

    In this paper, a new algorithm computing the power flow for multi-area power systems is presented. This algorithm is suitable for synchronous areas interconnected by means of AC tie-lines. In particular, a new iterative composition/decomposition matrix procedure is adopted. For each control area, the classical PV, PQ and slack bus constraints are defined, hence the power flow solutions of each control area can be computed independently. In case, this independence allows exploiting the parallel computation technique. The overall power flow is then computed by putting together all the solutions of each control area iteratively, by means of the tie-line ( i.e ., the lines interconnecting the areas) admittance matrix. The present multi-area method is completely general and once the power flow solution of each area is separately achieved by any power flow solver (e.g., Newton-Raphson and derived, PFPD, or other), it makes suitable use of both a Thevenin’s theorem generalization and a novel tie-line admittance matrix. In this direction, the method is not a new power flow algorithm but a new multi-area one which starts from the solutions of the power flow of area, each of that with its own slack-bus. Applications of the algorithm to standard test cases are presented. Eventually, to test the validity of the method, numerical comparisons with the commercial software DIgSILENT PowerFactory are performed.


  • Open Access

    Multiconductor Cell Analysis of AC High Speed Railway Lines

    by Roberto Benato, Giovanni Gardan, Luca Rusalen

    The aim of this paper is the application of Multiconductor Cell Analysis to a very special case of a multiconductor system, i.e ., the AC high-speed railway system, with 14 parallel conductors. The present matrix approach allows representing both the single elements and the entire railway system also including the high voltage three-phase supply network. The algorithm allows computing all the steady-state regime electrical quantities (voltages, currents and power) of each section: in particular, the ground return current, responsible for electromagnetic interferences, can be derived by the knowledge of all the circulating currents. It is also possible to evaluate the electric unbalance impact on the supply three-phase power system given by the railway system. Eventually, two different scenarios are presented, i.e ., a maximum allowable high-speed line power request and a contact-wire to rail short circuit.