Luca Rusalen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Luca Rusalen has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Roberto Benato
Department of Industrial Engineering, University of Padova, Via Gradenigo 6/A, 35131 Padova, Italy
4 shared publications - Giovanni Gardan
Dipartimento di Ingegneria Industriale, Università degli Studi di Padova, 35131 Padova, Italy
3 shared publications Fabio Trombini
Terna S.p.A., Padova, Italy
1 shared publication- Francesco Sanniti
Department of Industrial Engineering, University of Padova, 35131 Padova, Italy
1 shared publication Gilberto Ricci
Terna S.p.A., Padova, Italy
1 shared publicationLuciano Minto
Terna S.p.A., Padova, Italy
1 shared publication
Latest Publications
- 10 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 5140-5148
Experimental Validation of Multiconductor Cell Analysis by Overhead Line Field Measurements
Multiconductor Cell Analysis (MCA) is a matrix algorithm computing the electrical steady-state regime of any asymmetrical multiconductor system. This paper presents two experimental validations of MCA, which are carried out by two measurement campaigns performed in two different areas of Italy: on the Extra High Voltage (EHV) double-circuit OverHead Line (OHL) Dolo-Venezia Nord (18 km long) and on Suvereto-Montalto di Castro (120 km long) EHV OHL. By considering the double-circuit configuration of these lines, it has been assessed the impact of one inducing circuit, kept in service, on the other circuit, kept out of service, for the evaluation of induced voltages and currents. The induced circuit experiences induced voltage magnitudes ranging from about 4 kV to 30 kV when it is open at both ends, whereas the induced voltages are negligible but the current magnitudes ranging from 10 A to 28 A when it is grounded at both ends. The maximum mismatch between measurements and MCA results is 8,6% of the induced voltage magnitude of the phase closest to the earth. This mismatch is theoretically explainable by considering that this phase is the more subjected to the presence of unknown proximity objects along the route which could alter the electric field. One more time, comparisons between computations and measurements confirm the very good agreement between MCA and the physical behavior of asymmetric multiconductor systems.
- 10 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 5140-5148
Experimental Validation of Multiconductor Cell Analysis by Overhead Line Field Measurements
Multiconductor Cell Analysis (MCA) is a matrix algorithm computing the electrical steady-state regime of any asymmetrical multiconductor system. This paper presents two experimental validations of MCA, which are carried out by two measurement campaigns performed in two different areas of Italy: on the Extra High Voltage (EHV) double-circuit OverHead Line (OHL) Dolo-Venezia Nord (18 km long) and on Suvereto-Montalto di Castro (120 km long) EHV OHL. By considering the double-circuit configuration of these lines, it has been assessed the impact of one inducing circuit, kept in service, on the other circuit, kept out of service, for the evaluation of induced voltages and currents. The induced circuit experiences induced voltage magnitudes ranging from about 4 kV to 30 kV when it is open at both ends, whereas the induced voltages are negligible but the current magnitudes ranging from 10 A to 28 A when it is grounded at both ends. The maximum mismatch between measurements and MCA results is 8,6% of the induced voltage magnitude of the phase closest to the earth. This mismatch is theoretically explainable by considering that this phase is the more subjected to the presence of unknown proximity objects along the route which could alter the electric field. One more time, comparisons between computations and measurements confirm the very good agreement between MCA and the physical behavior of asymmetric multiconductor systems.
- Open Access
Assessing the Static Security of the Italian Grid by Means of the N-1 Three-Phase Contingency Analysis
The ongoing replacement of synchronous machine generators (SMs) with converter-interface generators (CIGs) is raising the voltage unbalance of power systems, affecting power quality and grid stability. This paper focuses on a key power quality index for power systems, i.e., the voltage unbalance factor. The purpose of this work is twofold. First, it presents the generalization of a three-phase power flow algorithm developed by University of Padova, named PFPD_3P, to assess the voltage unbalance factors of power systems supplied by CIGs. In particular, it is demonstrated that CIGs can be modelled as three-phase PV/PQ constraints embedding their positive-, negative- and zero-sequence admittances. Then, the concept of three-phase contingency analysis is introduced. Indeed, for static security evaluation, the classical single-phase contingency analysis may no longer be sufficient, as it lacks power quality computations, e.g., voltage/current unbalance factors. Numerical simulations evaluating the unbalance factors due to different generation mix scenarios and contingencies are tested on the Italian extra-high-voltage/high-voltage (EHV/HV) grid. The choice of this network relies on its representativeness, as CIGs are the majority of new installations in the Italian generation mix.
Open AccessAssessing the Static Security of the Italian Grid by Means of the N-1 Three-Phase Contingency Analysis
The ongoing replacement of synchronous machine generators (SMs) with converter-interface generators (CIGs) is raising the voltage unbalance of power systems, affecting power quality and grid stability. This paper focuses on a key power quality index for power systems, i.e., the voltage unbalance factor. The purpose of this work is twofold. First, it presents the generalization of a three-phase power flow algorithm developed by University of Padova, named PFPD_3P, to assess the voltage unbalance factors of power systems supplied by CIGs. In particular, it is demonstrated that CIGs can be modelled as three-phase PV/PQ constraints embedding their positive-, negative- and zero-sequence admittances. Then, the concept of three-phase contingency analysis is introduced. Indeed, for static security evaluation, the classical single-phase contingency analysis may no longer be sufficient, as it lacks power quality computations, e.g., voltage/current unbalance factors. Numerical simulations evaluating the unbalance factors due to different generation mix scenarios and contingencies are tested on the Italian extra-high-voltage/high-voltage (EHV/HV) grid. The choice of this network relies on its representativeness, as CIGs are the majority of new installations in the Italian generation mix.
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (6) , 8067-8076
Application to the Italian AC/DC EHV Network of the Paduan Three-phase Power Flow (PFPD_3P)
The HVDC tie lines represent a growing solution for the transmission system operators in order to dispatch the renewable source plant production on long distances. In the Italian transmission network, there are currently five HVDC links and other two are planned ( i.e. , Tyrrhenian Link and Adriatic Link). In this paper the matrix algorithm PFPD_3P is generalized in order to assess the power quality of real and large AC/DC transmission networks. The method is applied to study the voltage unbalance in two case studies: a 76-busbar network, and the Italian AC/DC HV/EHV network. In order to validate the method, solution comparisons with the commercial software DIgSILENT PowerFactoy are performed for both case studies showing a good agreement. The HVDC-VSC/LCC links are modelled as PV/PQ constraints at the positive sequence, which represent both the AC and DC behavior of the HVDC links. Since three-phase power flow is fundamental to compute network power quality, converter zero/negative sequence circuit is considered for both VSC and LCC.
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (6) , 8067-8076
Application to the Italian AC/DC EHV Network of the Paduan Three-phase Power Flow (PFPD_3P)
The HVDC tie lines represent a growing solution for the transmission system operators in order to dispatch the renewable source plant production on long distances. In the Italian transmission network, there are currently five HVDC links and other two are planned ( i.e. , Tyrrhenian Link and Adriatic Link). In this paper the matrix algorithm PFPD_3P is generalized in order to assess the power quality of real and large AC/DC transmission networks. The method is applied to study the voltage unbalance in two case studies: a 76-busbar network, and the Italian AC/DC HV/EHV network. In order to validate the method, solution comparisons with the commercial software DIgSILENT PowerFactoy are performed for both case studies showing a good agreement. The HVDC-VSC/LCC links are modelled as PV/PQ constraints at the positive sequence, which represent both the AC and DC behavior of the HVDC links. Since three-phase power flow is fundamental to compute network power quality, converter zero/negative sequence circuit is considered for both VSC and LCC.
- Open Access
- 4 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 36415-36431
PFPD_MCA: A Multiconductor Power Flow
In this paper, the multiconductor extension of the previously developed three-phase power flow algorithm (named PFPD_3P) is presented. This multiconductor formulation has a general validity for both distribution and transmission networks. An iterative matrix formulation for the solution is throughout expounded. The present method allows computing the electrical quantities of all the network conductors: the active conductors and the passive ones (i.e., OHL ground wires, IC metallic screens/armours, and GIL enclosures). These electrical quantities can be evaluated both at the network busbars and also along the lines. The knowledge of these quantities can be useful to perform: safety issues, power quality and electromagnetic compatibility studies. The electrical substations are carefully modelled, by considering the links between the passive conductors of different busbars and the earthing resistance of the meshed earth electrode. The algorithm is implemented in Matlab environment and tested by several fictitious networks. Eventually, in order to confirm the approach accuracy, the multiconductor results are compared with the equivalent single-phase ones and the three-phase power flow commercial software DIgSILENT PowerFactory.
- 4 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 36415-36431
Open AccessPFPD_MCA: A Multiconductor Power Flow
In this paper, the multiconductor extension of the previously developed three-phase power flow algorithm (named PFPD_3P) is presented. This multiconductor formulation has a general validity for both distribution and transmission networks. An iterative matrix formulation for the solution is throughout expounded. The present method allows computing the electrical quantities of all the network conductors: the active conductors and the passive ones (i.e., OHL ground wires, IC metallic screens/armours, and GIL enclosures). These electrical quantities can be evaluated both at the network busbars and also along the lines. The knowledge of these quantities can be useful to perform: safety issues, power quality and electromagnetic compatibility studies. The electrical substations are carefully modelled, by considering the links between the passive conductors of different busbars and the earthing resistance of the meshed earth electrode. The algorithm is implemented in Matlab environment and tested by several fictitious networks. Eventually, in order to confirm the approach accuracy, the multiconductor results are compared with the equivalent single-phase ones and the three-phase power flow commercial software DIgSILENT PowerFactory.