SZShenghang Zhai

Shenghang Zhai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shenghang Zhai has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • AFM Vibration Noise Reduction via Squeeze-Film-Damping-Effect Sensing Method

    by Shenghang Zhai, Liang Liang, Jialin Shi, Peng Yu, Tie Yang, Yang Yang, Chanmin Su, Lianqing Liu

    Large industrial atomic force microscopy (AFM) plays a pivotal role in the metrology of large samples. However, significant vibrations between the large AFM and the sample can limit the resolution of the AFM. By detecting and subtracting these vibrations from the image signal, image noise can be effectively reduced. However, measuring these vibrations presents a challenge, particularly because most large samples are dielectric and fragile, which makes conventional electrical vibration sensors unsuitable. Furthermore, the frequency responses of the vibration sensor and the AFM differ. Therefore, directly subtracting the vibration signal from the AFM’s topography signal can lead to considerable errors owing to the magnitude and phase differences between these signals. In our study, we designed a non-contact vibration sensor leveraging the squeeze-film-damping-effect. This sensor can measure dielectric samples and achieve a high resolution (better than 0.1 nm). We processed the measured vibration signal using a magnitude-phase adjuster to compensate for the dynamic differences between the sensor and the AFM. We managed to limit the subtraction error to within 1 nm using this adjuster, achieving a reduction of 63-88% in subtraction errors. Additionally, we validated our vibration reduction method using topography images of standard grating samples.


  • Open Access

    An integrated hinged dual-probe for co-target fast switching imaging

    by Kaixuan Wang, Jialin Shi, Tie Yang, Si Tang, Peng Yu, Huiyao Shi, Shenghang Zhai, Chanmin Su, Lianqing Liu

    The diversity of functional applications of atomic force microscopes is the key to the development of nanotechnology. However, the single probe configuration of the traditional atomic force microscope restricts the realization of different application requirements for the same target area of a single sample, and the replacement of the working probe will lead to the loss of the target area. Here, the design, simulation, fabrication, and application of a unique atomic force microscope dual-probe are presented, which consists of a pair of parallel cantilevers with a narrow gap and a U-shaped hinged probe base. The Integrated Hinged Dual-Probe (IHDP) is developed specifically for fast switching of probes working in limited space and independent and precise manipulation of each probe. The deflection signal sensing of two cantilevers is achieved simultaneously by a single laser beam, and the decoupled independent cantilever deflection signals do not interfere with each other. The switching of the working probe is achieved by a piezoelectric ceramic with a 2 µm stroke and U-shaped hinge structure, which is fast and does not require tedious and repetitive spatial position calibration. By measuring standard grid samples, IHDP exhibits excellent measurement and characterization capabilities. Finally, a working probe switching imaging experiment was conducted on solidified rat cardiomyocytes, and the experimental process and imaging results demonstrated the superiority of IHDP in switching probe scanning imaging of the same target area of a single sample. The two probes of IHDP can undergo arbitrary functionalization modifications, which helps achieve multidimensional information acquisition for a single target.

  • Noncontact Subnanometer Resolution Displacement Sensing With Wide Bandwidth Based on Squeeze Film Damping Effect

    by Shenghang Zhai, Jialin Shi, Peng Yu, Tie Yang, Yang Yang, Chanmin Su, Lianqing Liu

    Displacement sensors with subnanometer resolution and wide bandwidth are essential for micro-nano manufacturing, measurement, and motion control systems. However, the current displacement sensing methods have various limitations, such as requirements for the optical or electrical properties of the target sample, the need to be in contact with the sample surface, and the contradiction between the accuracy and bandwidth. This study proposes a displacement sensing method with wide bandwidth and subnanometer resolution, which is not only insensitive to the material properties of the measured sample but is not in contact with the sample. The squeeze film damping (SFD) force exerted on the resonant micro-cantilever plate is sensitive to the plate-sample displacement (film height), which can be converted into the cantilever vibration amplitude. The resulting amplitude variations can be measured by the optical lever method. Herein, the mathematical model of the resonant cantilever and SFD force is established. The effects of driving amplitude and frequency on displacement sensing are studied. Evidently, increasing the driving amplitude and using a resonant driving frequency can improve sensing sensitivity and resolution. Experiments reveal that the proposed method is insensitive to sample material changes, has a resolution of 0.21 nm (STD), range of 5 μm, bandwidth of about 515 Hz, and can be utilized in gantry vibration measurement.


  • High-Speed Near-Surface Tracking for Fast Atomic Force Microscope Scan Switching Based on the Squeeze Film Damping Effect

    by Shenghang Zhai, Jialin Shi, Peng Yu, Huiyao Shi, Kaixuan Wang, Chanmin Su, Lianqing Liu

    Atomic force microscope (AFM) is a crucial metrology tool in the semiconductor industry. However, the bottleneck of the AFM technique is its low efficiency, primarily owing to the time-consuming scanning point switching. The traditional method takes approximately one minute for a single switching. To shield the probe and sample, the switching should first lift the probe a considerable distance, move it to the next point, and finally engage the probe slowly to the sample surface. We propose a near-surface tracking method for use in fast scanning point switching. The probe-sample distance was sensed by the squeeze air film damping effect, and the probe was kept at a small constant height during the switching via feedback control. The method can decrease the lift and engage distance from approximately 1 mm to 5 μm, which was two order of reduction; thereby shortening the single switching time from 45 s to 6.1 s, which is an 87% reduction. Generally, the fast switching method can improve the measurement efficiency of the existing AFM working in the air, but it can not be used in liquid and vacuum. Furthermore, the proposed squeeze film damping effect based distance sensing method can be applied in various fields, such as vibration sensing and temperature drift measurement.