Baoliang Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Baoliang Feng has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Changcheng Shi
Zhejiang International Scientific and Technological Cooperative Base of Biomedical Materials and Technology Zhejiang Engineering Research Center for Biomedical Materials Laboratory of Advanced Theranostic Materials and Technology Ningbo Institute of Materials Technology and Engineering Chinese Academy of Sciences Ningbo People's Republic of China
2 shared publications - Guokun Zuo
Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang, China
2 shared publications - Kaikai Wang
Cixi Biomedical Research Institute, Wenzhou Medical University, Ningbo, Zhejiang, China
2 shared publications Binjun Shi
Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, China
1 shared publication- Binjun Shi
Ningbo Cixi Institute of Biomedical Engineering, Ningbo, China
1 shared publication Dazheng Zhao
Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, China
1 shared publication
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (21) , 49357-49374
A Noncontact Capacitive ECG Smart Mattress System Using Sensor Arrays and Adaptive Switching Strategy for Unconstrained In-Bed Sleep
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (21) , 49357-49374
A Noncontact Capacitive ECG Smart Mattress System Using Sensor Arrays and Adaptive Switching Strategy for Unconstrained In-Bed Sleep
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-14
Noncontact in Bed Measurements of Electrocardiogram Using a Capacitively Coupled Electrode Array Based on Flexible Circuit Board
Unconstrained vital sign monitoring technology has been a hot topic of research in recent years as people increasingly focus on their health status and sleep quality. Conventional contact electrocardiogram (ECG) measurement technology has difficulties in meeting the application needs of sleep scenarios due to short validity period and low comfort. To handle this problem, ECG measurement using non-contact capacitively coupled sensing technology, which do not require direct skin contact for ECG signal acquisition, could be an alternative. However, this method requires fixing the ECG measurement electrodes in two specific positions, which makes it difficult to meet the needs for body differences and multiple sleep postures. This study presents a non-contact sleep ECG measurement system based on a flexible electrode array, which can acquire ECG signals through pajamas and bed sheets using the principle of capacitive coupling. The experiment results showed that the average signal-to-noise ratio (SNR) of the data measured in the supine and lateral postures of subjects was above 30 dB, and the respiratory waves (RW) with the same frequency as contact ECG measurement system could be extracted. We also used this system to acquire ECG signals from multiple points on the dorsal of four subjects and analyzed their variation patterns, and the experimental results were in high agreement with the ECG potential employment recorded by 32-lead body surface maps. Meanwhile, the T-wave, R-wave, S-wave peaks and the ratio of T and R waves of the collected ECG signals were extracted as features. Based on this, the action classification model was trained using long short-term memory network (LSTM) to classify the postures of four subjects in supine, left lateral and right lateral positions, and the classification accuracies were 95.83%, 98.94%, 98.80% and 98.30%, respectively. Although our prototype system must be further improvement and development, these results provide a strong basis for future realization of electrode array-based ECG signal selection algorithms. The proposed system has great potential value in detecting abnormalities of ECG, heart rate (HR), respiration and other vital indicators during human sleep and realizing personalized medical treatment.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-14
Noncontact in Bed Measurements of Electrocardiogram Using a Capacitively Coupled Electrode Array Based on Flexible Circuit Board
Unconstrained vital sign monitoring technology has been a hot topic of research in recent years as people increasingly focus on their health status and sleep quality. Conventional contact electrocardiogram (ECG) measurement technology has difficulties in meeting the application needs of sleep scenarios due to short validity period and low comfort. To handle this problem, ECG measurement using non-contact capacitively coupled sensing technology, which do not require direct skin contact for ECG signal acquisition, could be an alternative. However, this method requires fixing the ECG measurement electrodes in two specific positions, which makes it difficult to meet the needs for body differences and multiple sleep postures. This study presents a non-contact sleep ECG measurement system based on a flexible electrode array, which can acquire ECG signals through pajamas and bed sheets using the principle of capacitive coupling. The experiment results showed that the average signal-to-noise ratio (SNR) of the data measured in the supine and lateral postures of subjects was above 30 dB, and the respiratory waves (RW) with the same frequency as contact ECG measurement system could be extracted. We also used this system to acquire ECG signals from multiple points on the dorsal of four subjects and analyzed their variation patterns, and the experimental results were in high agreement with the ECG potential employment recorded by 32-lead body surface maps. Meanwhile, the T-wave, R-wave, S-wave peaks and the ratio of T and R waves of the collected ECG signals were extracted as features. Based on this, the action classification model was trained using long short-term memory network (LSTM) to classify the postures of four subjects in supine, left lateral and right lateral positions, and the classification accuracies were 95.83%, 98.94%, 98.80% and 98.30%, respectively. Although our prototype system must be further improvement and development, these results provide a strong basis for future realization of electrode array-based ECG signal selection algorithms. The proposed system has great potential value in detecting abnormalities of ECG, heart rate (HR), respiration and other vital indicators during human sleep and realizing personalized medical treatment.
- 23 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (19) , 23583-23596
Parallel High Capacitance Capacitors Connected With Flexible Electrodes for Enhancement of cECG Signal Quality
In the application for sleeping cardiac monitoring utilizing capacitive electrocardiogram (cECG), a raw cECG signal with high-fidelity is typically difficult to be obtained due to the low coupling capacitance made up of human skin, low dielectric fabrics and sensing electrodes. In order to overcome this challenge, this study proposed a parallel capacitor-flexible electrode for enhancing the performance of ECG monitoring system and investigated the influence of the parallel capacitors on ECG monitoring. Parallel capacitors at both ends of the coupling capacitance could increase the coupling capacitance and reduce the equivalent impedance, which could improve the signal-to-noise ratio (SNR) (from about 10dB to more than 30dB) of the acquired cECG signals. In this study, firstly, the optimal connection point and parallel capacitor were determined; secondly, the application of proposed system was demonstrated and well-characterized cECG signals (SNR 35.066dB) were obtained. The cECG signals acquired by the proposed and reference system were in good agreement. The calculated intervals of all subjects extracted from the cECG signals were within the standard interval ranges, which was consistent with the health condition of the subjects. The results also showed that the proposed system had an average HR error of 1.4% for 20 minutes compared to the reference system. In conclusion, this study innovatively proposed a method to enhance cECG signal quality, which has a promising potential for long-term sleeping ECG monitoring.
- 23 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (19) , 23583-23596
Parallel High Capacitance Capacitors Connected With Flexible Electrodes for Enhancement of cECG Signal Quality
In the application for sleeping cardiac monitoring utilizing capacitive electrocardiogram (cECG), a raw cECG signal with high-fidelity is typically difficult to be obtained due to the low coupling capacitance made up of human skin, low dielectric fabrics and sensing electrodes. In order to overcome this challenge, this study proposed a parallel capacitor-flexible electrode for enhancing the performance of ECG monitoring system and investigated the influence of the parallel capacitors on ECG monitoring. Parallel capacitors at both ends of the coupling capacitance could increase the coupling capacitance and reduce the equivalent impedance, which could improve the signal-to-noise ratio (SNR) (from about 10dB to more than 30dB) of the acquired cECG signals. In this study, firstly, the optimal connection point and parallel capacitor were determined; secondly, the application of proposed system was demonstrated and well-characterized cECG signals (SNR 35.066dB) were obtained. The cECG signals acquired by the proposed and reference system were in good agreement. The calculated intervals of all subjects extracted from the cECG signals were within the standard interval ranges, which was consistent with the health condition of the subjects. The results also showed that the proposed system had an average HR error of 1.4% for 20 minutes compared to the reference system. In conclusion, this study innovatively proposed a method to enhance cECG signal quality, which has a promising potential for long-term sleeping ECG monitoring.