J. Morgan Micheletti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
J. Morgan Micheletti has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Brad Hall
Sengi, Penniac, NB, Canada
4 shared publications Inder Paul Singh
The Eye Centers of Racine & Kenosha, Kenosha, WI, USA
2 shared publications- Liliana Werner
John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
2 shared publications - Andrea Ortiz1 shared publication
Audrey C Mok
Eye Treatment Center, Long Beach, CA, USA
1 shared publicationAustin Bell
BoozmanHof Eye Center, Rogers, AR, USA
1 shared publication
Latest Publications
- Open Access
- 5 November 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Joint Assessment of Materials Exposure in Space: laboratory analyses of intraocular lenses after low-Earth-orbit exposure on the exterior of the International Space Station
Purpose: To evaluate effects of low Earth orbit (LEO) space conditions on intraocular lenses (IOLs) manufactured from different materials. Setting: International Space Station (ISS); Intermountain Ocular Research Center (John A. Moran Eye Center, University of Utah, Salt Lake City, Utah). Design: Experimental study. Methods: 135 IOLs made of hydrophobic acrylic, hydrophilic acrylic, and silicone materials were launched to the ISS as pressurized cargo. Of these, 61 were analyzed. On the ISS, the IOLs were placed in 3 external locations, differentiated by their exposure conditions: Ram (high atomic oxygen flux), Zenith (filtered UV-channel exposure), and Underdeck (external ISS environment with partial shielding). 45 corresponding controls remained on Earth. Of these, 20 were analyzed. After 6 months, the flight IOLs returned to Earth; 61 flight IOLs and 20 controls underwent gross and light microscopy. Changes were further assessed through scanning electron microscopy coupled with elemental analyses or spectrophotometry. Results: Postmission analysis of space-exposed IOLs demonstrated changes consistent with polymer erosion in 5 hydrophobic and 3 hydrophilic acrylic IOLs. 2 hydrophobic acrylic and 3 silicone lenses demonstrated yellow optic discoloration with changes in light transmission. These IOLs were all in the tray closest to exposure to Ram or Zenith conditions. All 6 space-exposed light-adjustable lenses in the 3 locations, with or without ActivShield, exhibited similar “cobblestone” changes on the anterior and posterior optic surfaces, as well as the optic edge. Conclusions: This exploratory study showed that IOL materials may differ in susceptibility to environmental hazards in LEO. These findings may inform packaging, shipping, and storage of IOLs in space because ophthalmic care will be required for future long-duration space missions and eventual extraterrestrial habitation.
- 5 November 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Open AccessJoint Assessment of Materials Exposure in Space: laboratory analyses of intraocular lenses after low-Earth-orbit exposure on the exterior of the International Space Station
Purpose: To evaluate effects of low Earth orbit (LEO) space conditions on intraocular lenses (IOLs) manufactured from different materials. Setting: International Space Station (ISS); Intermountain Ocular Research Center (John A. Moran Eye Center, University of Utah, Salt Lake City, Utah). Design: Experimental study. Methods: 135 IOLs made of hydrophobic acrylic, hydrophilic acrylic, and silicone materials were launched to the ISS as pressurized cargo. Of these, 61 were analyzed. On the ISS, the IOLs were placed in 3 external locations, differentiated by their exposure conditions: Ram (high atomic oxygen flux), Zenith (filtered UV-channel exposure), and Underdeck (external ISS environment with partial shielding). 45 corresponding controls remained on Earth. Of these, 20 were analyzed. After 6 months, the flight IOLs returned to Earth; 61 flight IOLs and 20 controls underwent gross and light microscopy. Changes were further assessed through scanning electron microscopy coupled with elemental analyses or spectrophotometry. Results: Postmission analysis of space-exposed IOLs demonstrated changes consistent with polymer erosion in 5 hydrophobic and 3 hydrophilic acrylic IOLs. 2 hydrophobic acrylic and 3 silicone lenses demonstrated yellow optic discoloration with changes in light transmission. These IOLs were all in the tray closest to exposure to Ram or Zenith conditions. All 6 space-exposed light-adjustable lenses in the 3 locations, with or without ActivShield, exhibited similar “cobblestone” changes on the anterior and posterior optic surfaces, as well as the optic edge. Conclusions: This exploratory study showed that IOL materials may differ in susceptibility to environmental hazards in LEO. These findings may inform packaging, shipping, and storage of IOLs in space because ophthalmic care will be required for future long-duration space missions and eventual extraterrestrial habitation.
- Open Access
- 1 October 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-12
Real-World Multicenter Evaluation of Ab-Interno Canaloplasty Using a New Canaloplasty Device with and without Concomitant Phacoemulsification in Uncontrolled Open-Angle Glaucoma: 12-Month Outcomes
Purpose: To report real-world outcomes of ab-interno canaloplasty using the second-generation iTrack Advance in patients with open-angle glaucoma (OAG). Patients and Methods: This retrospective, observational, multicenter study reviewed consecutive ab-interno canaloplasty procedures performed using the iTrack Advance (Nova Eye Medical, US) across 11 US sites between 2022 and 2024. Eligible eyes had mild-to-moderate OAG, uncontrolled baseline intraocular pressure (IOP) ≥ 18 mmHg and < 36 mmHg and at least 12 months of follow-up. Outcome measures included IOP and topical medication burden at 1, 6 and 12 months postop. Secondary outcomes included surgical success according to American Academy of Ophthalmology (AAO) criteria. Safety outcomes included complications, visual field mean deviation (VF MD), and additional glaucoma procedures. Results: Eighty-two eyes of 82 patients (mean age 72.0± 7.5 years) were included; 78 (95%) underwent canaloplasty combined with phacoemulsification and 4 (5%) underwent standalone canaloplasty. IOP in combined eyes decreased significantly from 20.7± 2.9 mmHg preoperatively to 15.0± 3.8 mmHg at 12 months (− 27%; p< 0.001), and medication burden reduced from 1.45± 1.2 to 1.06± 1.2 (− 26.5%; p=0.013). Success by AAO criteria was achieved in 64% of combined eyes. Among all 82 eyes, 85% achieved IOP ≤ 18 mmHg and 40% were medication-free. Postoperative complications were mild and transient, with no sight-threatening complications related to canaloplasty. VF MD remained stable at 12 months. One eye (1.2%) required an additional glaucoma procedure. Conclusion: In real-world practice, ab-interno canaloplasty performed using iTrack Advance in mild-to-moderate uncontrolled OAG achieved significant and sustained reductions in IOP and medication burden over 12 months with a favorable safety profile.
- 1 October 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-12
Open AccessReal-World Multicenter Evaluation of Ab-Interno Canaloplasty Using a New Canaloplasty Device with and without Concomitant Phacoemulsification in Uncontrolled Open-Angle Glaucoma: 12-Month Outcomes
Purpose: To report real-world outcomes of ab-interno canaloplasty using the second-generation iTrack Advance in patients with open-angle glaucoma (OAG). Patients and Methods: This retrospective, observational, multicenter study reviewed consecutive ab-interno canaloplasty procedures performed using the iTrack Advance (Nova Eye Medical, US) across 11 US sites between 2022 and 2024. Eligible eyes had mild-to-moderate OAG, uncontrolled baseline intraocular pressure (IOP) ≥ 18 mmHg and < 36 mmHg and at least 12 months of follow-up. Outcome measures included IOP and topical medication burden at 1, 6 and 12 months postop. Secondary outcomes included surgical success according to American Academy of Ophthalmology (AAO) criteria. Safety outcomes included complications, visual field mean deviation (VF MD), and additional glaucoma procedures. Results: Eighty-two eyes of 82 patients (mean age 72.0± 7.5 years) were included; 78 (95%) underwent canaloplasty combined with phacoemulsification and 4 (5%) underwent standalone canaloplasty. IOP in combined eyes decreased significantly from 20.7± 2.9 mmHg preoperatively to 15.0± 3.8 mmHg at 12 months (− 27%; p< 0.001), and medication burden reduced from 1.45± 1.2 to 1.06± 1.2 (− 26.5%; p=0.013). Success by AAO criteria was achieved in 64% of combined eyes. Among all 82 eyes, 85% achieved IOP ≤ 18 mmHg and 40% were medication-free. Postoperative complications were mild and transient, with no sight-threatening complications related to canaloplasty. VF MD remained stable at 12 months. One eye (1.2%) required an additional glaucoma procedure. Conclusion: In real-world practice, ab-interno canaloplasty performed using iTrack Advance in mild-to-moderate uncontrolled OAG achieved significant and sustained reductions in IOP and medication burden over 12 months with a favorable safety profile.
- Open Access
- 1 September 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-12
Visual, Refractive, and Patient-Reported Outcomes Following Bilateral Implantation of an Enhanced Monofocal IOL: An Exploratory Comparison of Achieved Mini-Monovision and Bilateral Emmetropia
Purpose: To compare the clinical and patient-reported outcomes following bilateral implantation of partial-depth-of-field enhanced monofocal IOL in subjects achieving bilateral emmetropia vs mini-monovision. Patients and Methods: This prospective, non-interventional, multicenter, cross-sectional study included subjects who had undergone cataract surgery and implantation of enVista Aspire IOL. For the post hoc analysis, patients were classified into bilateral emmetropia (BE) or mini-monovision (MM) based on achieved postoperative manifest refraction. Postoperative assessments included visual outcomes, manifest refraction, defocus curve, contrast sensitivity function, and patient-reported outcomes of questionnaires (AIOLIS and NAVQ). Results: In the BE group (N = 49), the mean MRSE in the first and the second operated eye was − 0.18 ± 0.26 D and − 0.11 ± 0.26 D, respectively, and the mean UDVA was 0.07 ± 0.11 logMAR and 0.05 ± 0.12 logMAR, respectively. Mean UIVA in the first- and second-operated eyes of the BE group was ~0.23 logMAR, and mean UNVA was ~0.46 logMAR. In the MM group (N = 21), with the mean MRSE of − 0.33 ± 0.17 D, the mean UDVA in the distance eye was 0.11 ± 0.12 logMAR. With a mean MRSE of − 0.96 ± 0.34 D, mean UIVA and UNVA of the intermediate eye were 0.13 ± 0.09 logMAR and 0.29 ± 0.16 logMAR, respectively. The defocus curve showed 0.2 logMAR or better visual acuity up to a myopic defocus of ~-1.25 D. A higher proportion (~14 to 31%) of subjects in the MM group reported "no or little difficulty” with various intermediate- to near-vision-related tasks. The frequency and bothersomeness of visual symptoms were similar between the two groups. A total of 85.7% of subjects in the MM group were "completely to very satisfied” with their overall postoperative vision compared to the BE group (77.6%). Conclusion: The MM group demonstrated improved intermediate and near visual performance and favorable patient-reported outcomes.
- 1 September 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-12
Open AccessVisual, Refractive, and Patient-Reported Outcomes Following Bilateral Implantation of an Enhanced Monofocal IOL: An Exploratory Comparison of Achieved Mini-Monovision and Bilateral Emmetropia
Purpose: To compare the clinical and patient-reported outcomes following bilateral implantation of partial-depth-of-field enhanced monofocal IOL in subjects achieving bilateral emmetropia vs mini-monovision. Patients and Methods: This prospective, non-interventional, multicenter, cross-sectional study included subjects who had undergone cataract surgery and implantation of enVista Aspire IOL. For the post hoc analysis, patients were classified into bilateral emmetropia (BE) or mini-monovision (MM) based on achieved postoperative manifest refraction. Postoperative assessments included visual outcomes, manifest refraction, defocus curve, contrast sensitivity function, and patient-reported outcomes of questionnaires (AIOLIS and NAVQ). Results: In the BE group (N = 49), the mean MRSE in the first and the second operated eye was − 0.18 ± 0.26 D and − 0.11 ± 0.26 D, respectively, and the mean UDVA was 0.07 ± 0.11 logMAR and 0.05 ± 0.12 logMAR, respectively. Mean UIVA in the first- and second-operated eyes of the BE group was ~0.23 logMAR, and mean UNVA was ~0.46 logMAR. In the MM group (N = 21), with the mean MRSE of − 0.33 ± 0.17 D, the mean UDVA in the distance eye was 0.11 ± 0.12 logMAR. With a mean MRSE of − 0.96 ± 0.34 D, mean UIVA and UNVA of the intermediate eye were 0.13 ± 0.09 logMAR and 0.29 ± 0.16 logMAR, respectively. The defocus curve showed 0.2 logMAR or better visual acuity up to a myopic defocus of ~-1.25 D. A higher proportion (~14 to 31%) of subjects in the MM group reported "no or little difficulty” with various intermediate- to near-vision-related tasks. The frequency and bothersomeness of visual symptoms were similar between the two groups. A total of 85.7% of subjects in the MM group were "completely to very satisfied” with their overall postoperative vision compared to the BE group (77.6%). Conclusion: The MM group demonstrated improved intermediate and near visual performance and favorable patient-reported outcomes.
- Open Access
- 1 January 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-9
Satisfaction and Visual Outcomes with a Non-Diffractive EDOF IOL in Post-Myopic LASIK and PRK Patients with High Corneal Spherical Aberration
Purpose: To evaluate patient satisfaction and visual outcomes with extended depth of focus (EDOF) intraocular lens (IOL) implantation in post myopic refractive surgery patients with high corneal spherical aberrations. Methods: This was a non-interventional, observational, ambispective, bilateral, single center multi-surgeon study. Patients had history of myopic LASIK or PRK, and relatively high corneal spherical aberrations, and were bilaterally implanted with Vivity or Vivity toric EDOF IOLs targeting emmetropia. Endpoints included monocular and binocular uncorrected and distance corrected visual acuities at distance (UDVA, CDVA), intermediate (UIVA, DCIVA; 66cm), and near (UNVA, DCNVA; 40cm), binocular defocus curve, and patient satisfaction (IOLSAT) and visual disturbance (QUVID) questionnaires. Results: A total of 20 subjects (40 eyes) completed the study. Mean binocular UDVA, UIVA, and UNVA were 0.02 ± 0.16 logMAR, 0.14 ± 0.13 logMAR, and 0.24 ± 0.14 logMAR, respectively. The percentages of eyes with mean residual spherical equivalent and residual astigmatism ≤ 0.50 D were 95% (38/40) and 98% (39/40), respectively. On the QUVID questionnaire, 0% (0/20), 5% (1/20), and 0% (0/20) of patients reported being “Bothered quite a bit” or “Bothered very much” by halo, starbursts, or glare, respectively. On the IOLSAT, patient reported spectacle use was “Never” or “Rarely” in 90% (18/20), 75% (15/20), and 30% (6/20) of patients at distance, intermediate, and near, respectively. Conclusion: Results suggest good visual outcomes at distance, intermediate and functional near vision and high patient satisfaction with Vivity and Vivity toric IOL implantation in post myopic refractive surgery patients with high corneal spherical aberrations.
- 1 January 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-9
Open AccessSatisfaction and Visual Outcomes with a Non-Diffractive EDOF IOL in Post-Myopic LASIK and PRK Patients with High Corneal Spherical Aberration
Purpose: To evaluate patient satisfaction and visual outcomes with extended depth of focus (EDOF) intraocular lens (IOL) implantation in post myopic refractive surgery patients with high corneal spherical aberrations. Methods: This was a non-interventional, observational, ambispective, bilateral, single center multi-surgeon study. Patients had history of myopic LASIK or PRK, and relatively high corneal spherical aberrations, and were bilaterally implanted with Vivity or Vivity toric EDOF IOLs targeting emmetropia. Endpoints included monocular and binocular uncorrected and distance corrected visual acuities at distance (UDVA, CDVA), intermediate (UIVA, DCIVA; 66cm), and near (UNVA, DCNVA; 40cm), binocular defocus curve, and patient satisfaction (IOLSAT) and visual disturbance (QUVID) questionnaires. Results: A total of 20 subjects (40 eyes) completed the study. Mean binocular UDVA, UIVA, and UNVA were 0.02 ± 0.16 logMAR, 0.14 ± 0.13 logMAR, and 0.24 ± 0.14 logMAR, respectively. The percentages of eyes with mean residual spherical equivalent and residual astigmatism ≤ 0.50 D were 95% (38/40) and 98% (39/40), respectively. On the QUVID questionnaire, 0% (0/20), 5% (1/20), and 0% (0/20) of patients reported being “Bothered quite a bit” or “Bothered very much” by halo, starbursts, or glare, respectively. On the IOLSAT, patient reported spectacle use was “Never” or “Rarely” in 90% (18/20), 75% (15/20), and 30% (6/20) of patients at distance, intermediate, and near, respectively. Conclusion: Results suggest good visual outcomes at distance, intermediate and functional near vision and high patient satisfaction with Vivity and Vivity toric IOL implantation in post myopic refractive surgery patients with high corneal spherical aberrations.
- Open Access
- 1 February 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (2) , 156-160
Assessment of measurement variability across automated biometry devices
Purpose: To evaluate measurement variability between different readily available automated biometric devices for the purposes of improving surgeon decision-making for phakic intraocular lens (IOL) sizing. Setting: Private practice (Houston, Texas). Design: Prospective, single-center, bilateral, nonrandomized, open-label, observational study. Methods: This study included healthy eyes, with no prior eye surgery, and with a spherical equivalent of at least −1.00 diopter. Orbscan II was compared with Argos, Atlas 9000, caliper, IOLMaster 500, IOLMaster 700, iTrace, Lenstar LS900, Pentacam HR, and Pentacam AXL Wave. Preoperative measurements included white-to-white (WTW), anterior chamber depth (ACD), and central corneal thickness (CCT). Linear mixed-effect models were created to determine adjustment factor between the Orbscan II and other devices for WTW, ACD, and CCT measurements. Results: 204 participants (408 eyes) completed the study. All mean WTW measurements were significantly different compared with the Orbscan II (P < .01), except for Pentacam AXL Wave. All mean ACD and CCT measurements were significantly different compared with the Orbscan II (P < .01). Adjustment factors for WTW ranged from −0.65 to 0.24 mm. Adjustment factors for ACD ranged from −0.21 to −0.16 mm. Adjustment factors for CCT ranged from 19.9 to −36.0 μm. Conclusions: The biometers tested were not interchangeable with the Orbscan II. Adjustment factors for WTW and ACD may compensate for differences between devices and adapt ICL sizing recommendations.
- 1 February 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (2) , 156-160
Open AccessAssessment of measurement variability across automated biometry devices
Purpose: To evaluate measurement variability between different readily available automated biometric devices for the purposes of improving surgeon decision-making for phakic intraocular lens (IOL) sizing. Setting: Private practice (Houston, Texas). Design: Prospective, single-center, bilateral, nonrandomized, open-label, observational study. Methods: This study included healthy eyes, with no prior eye surgery, and with a spherical equivalent of at least −1.00 diopter. Orbscan II was compared with Argos, Atlas 9000, caliper, IOLMaster 500, IOLMaster 700, iTrace, Lenstar LS900, Pentacam HR, and Pentacam AXL Wave. Preoperative measurements included white-to-white (WTW), anterior chamber depth (ACD), and central corneal thickness (CCT). Linear mixed-effect models were created to determine adjustment factor between the Orbscan II and other devices for WTW, ACD, and CCT measurements. Results: 204 participants (408 eyes) completed the study. All mean WTW measurements were significantly different compared with the Orbscan II (P < .01), except for Pentacam AXL Wave. All mean ACD and CCT measurements were significantly different compared with the Orbscan II (P < .01). Adjustment factors for WTW ranged from −0.65 to 0.24 mm. Adjustment factors for ACD ranged from −0.21 to −0.16 mm. Adjustment factors for CCT ranged from 19.9 to −36.0 μm. Conclusions: The biometers tested were not interchangeable with the Orbscan II. Adjustment factors for WTW and ACD may compensate for differences between devices and adapt ICL sizing recommendations.
- Open Access
- 1 January 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 309-316
Visual Outcomes and Patient Satisfaction of Two Continuous Range of Vision Intraocular Lenses
Purpose: To determine if visual outcomes with PanOptix are non-inferior to visual outcomes with Synergy. Methods: This was an ambispective, single center, comparative, bilateral, observational study. Patients received bilateral implantation with either PanOptix or Synergy intraocular lenses (IOLs) and were enrolled at least 5 months after surgeries. Patients with postoperative spherical equivalent ± 0.50D and astigmatism ≤ 0.75D in both eyes were enrolled. Postoperatively, patients were tested for binocular uncorrected and distance corrected visual acuities at distance, intermediate (60cm), and near (40cm and 33cm), binocular defocus curve, and were administered questionnaires about quality of vision (QUVID) and spectacle independence (IOLSAT). Results: A total of 230 subjects completed the study, 153 in the PanOptix group and 77 in the Synergy group. Non-inferiority of visual acuities were confirmed for all testing distances, with and without distance correction in place. No significant differences were observed for the binocular defocus curves (p > 0.05). Severity of starburst, halo, and glare were rated as “None” in 65% (98/150), 38% (58/152), and 48% (72/151) of subjects with the PanOptix Group, compared to 49% (37/76), 38% (29/77), and 55% (42/77) for the Synergy Group, respectively. The percentage of patients “Satisfied” or “Very Satisfied” with their vision was 89% (136/153) in the PanOptix group and 94% (72/77) in the Synergy group. Conclusion: The results of this study suggest excellent visual acuities at distance, intermediate, and near, high spectacle independence, and high patient satisfaction with both the PanOptix and Synergy IOLs. The incidence of starbursts and blurred vision, as well as visual acuities at extreme near (33 cm), may be higher with the Synergy IOL.
- 1 January 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 309-316
Open AccessVisual Outcomes and Patient Satisfaction of Two Continuous Range of Vision Intraocular Lenses
Purpose: To determine if visual outcomes with PanOptix are non-inferior to visual outcomes with Synergy. Methods: This was an ambispective, single center, comparative, bilateral, observational study. Patients received bilateral implantation with either PanOptix or Synergy intraocular lenses (IOLs) and were enrolled at least 5 months after surgeries. Patients with postoperative spherical equivalent ± 0.50D and astigmatism ≤ 0.75D in both eyes were enrolled. Postoperatively, patients were tested for binocular uncorrected and distance corrected visual acuities at distance, intermediate (60cm), and near (40cm and 33cm), binocular defocus curve, and were administered questionnaires about quality of vision (QUVID) and spectacle independence (IOLSAT). Results: A total of 230 subjects completed the study, 153 in the PanOptix group and 77 in the Synergy group. Non-inferiority of visual acuities were confirmed for all testing distances, with and without distance correction in place. No significant differences were observed for the binocular defocus curves (p > 0.05). Severity of starburst, halo, and glare were rated as “None” in 65% (98/150), 38% (58/152), and 48% (72/151) of subjects with the PanOptix Group, compared to 49% (37/76), 38% (29/77), and 55% (42/77) for the Synergy Group, respectively. The percentage of patients “Satisfied” or “Very Satisfied” with their vision was 89% (136/153) in the PanOptix group and 94% (72/77) in the Synergy group. Conclusion: The results of this study suggest excellent visual acuities at distance, intermediate, and near, high spectacle independence, and high patient satisfaction with both the PanOptix and Synergy IOLs. The incidence of starbursts and blurred vision, as well as visual acuities at extreme near (33 cm), may be higher with the Synergy IOL.
- Open Access
- 1 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (12) , 1284-1290
Standalone interventional glaucoma: evolution from the combination-cataract paradigm
One of the most impactful recent developments in the glaucoma community has been the concept of interventional glaucoma. In brief, this paradigm shift involves proactive rather than reactive intervention to address glaucoma earlier in the disease process, including in both standalone and combination-cataract settings. By intervening earlier with minimally invasive surgical, laser, or drug-delivery treatments instead of prolonged topical medications, interventional glaucoma aims to take the burden of medication compliance off the patient. It also allows for standalone surgical interventions rather than letting cataract surgery dictate the glaucoma treatment plan. This interventional mindset has been made possible by the increasing diversity and availability of effective minimally invasive treatment options. With these options as a springboard, it is time to reevaluate and advance the traditional glaucoma treatment paradigm.
- 1 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (12) , 1284-1290
Open AccessStandalone interventional glaucoma: evolution from the combination-cataract paradigm
One of the most impactful recent developments in the glaucoma community has been the concept of interventional glaucoma. In brief, this paradigm shift involves proactive rather than reactive intervention to address glaucoma earlier in the disease process, including in both standalone and combination-cataract settings. By intervening earlier with minimally invasive surgical, laser, or drug-delivery treatments instead of prolonged topical medications, interventional glaucoma aims to take the burden of medication compliance off the patient. It also allows for standalone surgical interventions rather than letting cataract surgery dictate the glaucoma treatment plan. This interventional mindset has been made possible by the increasing diversity and availability of effective minimally invasive treatment options. With these options as a springboard, it is time to reevaluate and advance the traditional glaucoma treatment paradigm.
- Open Access
- 30 November 2024
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 14 (1) , 13-22
An Emerging Multi-mechanism and Multi-modal Approach in Interventional Glaucoma Therapy
The glaucoma treatment paradigm is in evolution. The topical medications-first approach is limited by significant barriers such as high rates of nonadherence and side effects including ocular surface disease. The era of interventional glaucoma has seen the development of selective laser trabeculoplasty (SLT), procedural pharmaceuticals, and minimally invasive glaucoma surgeries (MIGS). New and emerging data support the use of these interventional treatment modalities early in the course of glaucoma rather than reserving them for advanced or treatment-recalcitrant cases. The various treatments available represent multiple mechanisms (e.g., trabecular outflow, uveoscleral outflow, aqueous suppression) and modalities (medications, laser, incisional surgery) by which intraocular pressure (IOP) is reduced. Many patients require more than one treatment to achieve adequate IOP reduction and glaucoma control. Comprehensive IOP control—reduction of both mean IOP and IOP fluctuation—can best be achieved by targeting multiple mechanisms of IOP reduction and taking advantage of the attributes of multiple treatment modalities.
- 30 November 2024
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 14 (1) , 13-22
Open AccessAn Emerging Multi-mechanism and Multi-modal Approach in Interventional Glaucoma Therapy
The glaucoma treatment paradigm is in evolution. The topical medications-first approach is limited by significant barriers such as high rates of nonadherence and side effects including ocular surface disease. The era of interventional glaucoma has seen the development of selective laser trabeculoplasty (SLT), procedural pharmaceuticals, and minimally invasive glaucoma surgeries (MIGS). New and emerging data support the use of these interventional treatment modalities early in the course of glaucoma rather than reserving them for advanced or treatment-recalcitrant cases. The various treatments available represent multiple mechanisms (e.g., trabecular outflow, uveoscleral outflow, aqueous suppression) and modalities (medications, laser, incisional surgery) by which intraocular pressure (IOP) is reduced. Many patients require more than one treatment to achieve adequate IOP reduction and glaucoma control. Comprehensive IOP control—reduction of both mean IOP and IOP fluctuation—can best be achieved by targeting multiple mechanisms of IOP reduction and taking advantage of the attributes of multiple treatment modalities.
- Open Access
- 1 September 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 2461-2466
Capsular Waves: A Warning Indicator for Potentially Malpositioned Intraocular Lenses
Purpose: To share examination findings of the lens capsule which may act as an indicator for malpositioned intraocular lenses (IOL). Setting: Single large multi-specialty private practice, Houston, Texas, USA. Design: Focused, observational case series. Methods: A review of pre-operative images of malpositioned single-piece IOLs with at least one haptic in the ciliary sulcus was conducted. The review included five cases who were referred to a single large multi-specialty private practice from June 2023 to December 2024 for an evaluation of posterior capsular opacification (PCO) and potential Nd:YAG capsulotomy. Findings: A total of five eyes which previously had undergone cataract surgery and were referred for Nd:YAG capsulotomy for PCO were identified on slit lamp examination to have capsular waves, defined as a centripetal and circumferential striated pattern of PCO that results from a fused anterior and posterior capsule with at least part of the IOL anterior to the capsule. While one eye exhibited transillumination defects and pigment dispersion, the remainder of eyes did not. In some cases, the capsular wave was the only clue to IOL malpositioning due to a small pupil. These eyes had single-piece IOLs with at least one haptic in the sulcus and required subsequent IOL repositioning or exchange. Conclusion: If capsular waves are seen on slit lamp exam, a thorough inspection of IOL placement should be conducted, especially before treatment with Nd:YAG capsulotomy. Capsular waves result from anterior and posterior capsule contact with an anteriorly situated IOL. This finding is a potential indicator of at least part of an IOL positioned anterior to the anterior capsule.
- 1 September 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 2461-2466
Open AccessCapsular Waves: A Warning Indicator for Potentially Malpositioned Intraocular Lenses
Purpose: To share examination findings of the lens capsule which may act as an indicator for malpositioned intraocular lenses (IOL). Setting: Single large multi-specialty private practice, Houston, Texas, USA. Design: Focused, observational case series. Methods: A review of pre-operative images of malpositioned single-piece IOLs with at least one haptic in the ciliary sulcus was conducted. The review included five cases who were referred to a single large multi-specialty private practice from June 2023 to December 2024 for an evaluation of posterior capsular opacification (PCO) and potential Nd:YAG capsulotomy. Findings: A total of five eyes which previously had undergone cataract surgery and were referred for Nd:YAG capsulotomy for PCO were identified on slit lamp examination to have capsular waves, defined as a centripetal and circumferential striated pattern of PCO that results from a fused anterior and posterior capsule with at least part of the IOL anterior to the capsule. While one eye exhibited transillumination defects and pigment dispersion, the remainder of eyes did not. In some cases, the capsular wave was the only clue to IOL malpositioning due to a small pupil. These eyes had single-piece IOLs with at least one haptic in the sulcus and required subsequent IOL repositioning or exchange. Conclusion: If capsular waves are seen on slit lamp exam, a thorough inspection of IOL placement should be conducted, especially before treatment with Nd:YAG capsulotomy. Capsular waves result from anterior and posterior capsule contact with an anteriorly situated IOL. This finding is a potential indicator of at least part of an IOL positioned anterior to the anterior capsule.
- Open Access
- 3 December 2023
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (6) , 665-672
Impact of presbyopia treatment pilocarpine hydrochloride 1.25% on night-driving performance
Patients prescribed pilocarpine ophthalmic solution are advised to be cautious when driving at night, but studies evaluating the effects of pilocarpine hydrochloride ophthalmic solution 1.25% (pilo), approved to treat presbyopia, on driving at night are lacking. This double-masked, crossover, phase 3b study evaluated night-driving performance with pilo or the placebo once daily. Forty-three adults (40-55 years) with presbyopia impacting daily activities and mesopic, high-contrast, binocular distance-corrected near vision 6/12-6/30 were randomised to bilateral treatment with pilo followed by placebo or placebo followed by pilo (with a ≥7-day washout between interventions). Night-driving performance was evaluated at twilight at a closed-circuit course. Primary efficacy endpoint: overall composite night-driving performance Z score at the end of the 7-14-day intervention period, 1 hour post-instillation. Pilo was considered non-inferior if the lower limit of the 95% confidence interval (CI) for the least squares mean difference (LSMD, pilo minus placebo) was >-0.25. Other efficacy endpoints: individual components of the night-driving performance test (hazard avoidance rate; road sign recognition rate and distance; pedestrians recognition distance; overall driving and lane-keeping times) and night-driving experience questionnaire. Safety included treatment-emergent adverse events (TEAEs). The mean overall composite Z scores were -0.121 (pilo) and 0.118 (placebo). The LSMD (pilo minus placebo) was -0.224 (95% CI, -0.346, -0.103), with 3 of the 7 individual tasks being significantly better with the placebo. The questionnaire did not reveal significant differences between pilo and the placebo. There were no serious or severe TEAEs and no TEAE-related discontinuations. The most common ocular TEAEs were headache and visual impairment with pilo (both 27.9%), and dry eye (7.0%) with the placebo. The overall performance of night driving was inferior with pilo, compared with placebo. The study findings are consistent with the current class labelling and provide evidence to inform regulators and assist clinicians considering prescribing pilo to adults who seek treatment of presbyopia symptoms and drive at night.ClinicalTrials.gov identifier: NCT04837482.
- 3 December 2023
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (6) , 665-672
Open AccessImpact of presbyopia treatment pilocarpine hydrochloride 1.25% on night-driving performance
Patients prescribed pilocarpine ophthalmic solution are advised to be cautious when driving at night, but studies evaluating the effects of pilocarpine hydrochloride ophthalmic solution 1.25% (pilo), approved to treat presbyopia, on driving at night are lacking. This double-masked, crossover, phase 3b study evaluated night-driving performance with pilo or the placebo once daily. Forty-three adults (40-55 years) with presbyopia impacting daily activities and mesopic, high-contrast, binocular distance-corrected near vision 6/12-6/30 were randomised to bilateral treatment with pilo followed by placebo or placebo followed by pilo (with a ≥7-day washout between interventions). Night-driving performance was evaluated at twilight at a closed-circuit course. Primary efficacy endpoint: overall composite night-driving performance Z score at the end of the 7-14-day intervention period, 1 hour post-instillation. Pilo was considered non-inferior if the lower limit of the 95% confidence interval (CI) for the least squares mean difference (LSMD, pilo minus placebo) was >-0.25. Other efficacy endpoints: individual components of the night-driving performance test (hazard avoidance rate; road sign recognition rate and distance; pedestrians recognition distance; overall driving and lane-keeping times) and night-driving experience questionnaire. Safety included treatment-emergent adverse events (TEAEs). The mean overall composite Z scores were -0.121 (pilo) and 0.118 (placebo). The LSMD (pilo minus placebo) was -0.224 (95% CI, -0.346, -0.103), with 3 of the 7 individual tasks being significantly better with the placebo. The questionnaire did not reveal significant differences between pilo and the placebo. There were no serious or severe TEAEs and no TEAE-related discontinuations. The most common ocular TEAEs were headache and visual impairment with pilo (both 27.9%), and dry eye (7.0%) with the placebo. The overall performance of night driving was inferior with pilo, compared with placebo. The study findings are consistent with the current class labelling and provide evidence to inform regulators and assist clinicians considering prescribing pilo to adults who seek treatment of presbyopia symptoms and drive at night.ClinicalTrials.gov identifier: NCT04837482.