Cheng Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cheng Li has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chao Fan
Hunan Key Laboratory of Mechanical Equipment Health Maintenance, Hunan University of Science and Technology, Xiangtan 411201, China
1 shared publication - Gaofeng Zheng
Pen‐Tung Sah Institute of Micro‐Nano Science and Technology Xiamen University Xiamen China
1 shared publication - Guanghui Cao
Zhengzhou BYD Automotive Co., Ltd., Zhengzhou 451162, China
1 shared publication - Ruimin Liu
Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361102, China
1 shared publication - Sai Li
Hunan Provincial Key Laboratory of Health Maintenance for Mechanical Equipment, Hunan University of Science and Technology, Xiangtan 411201, China
1 shared publication - Shumin Guo
Fujian Provincial Key Laboratory of Mathematical Modeling and High Performance Scientific Computing, School of Mathematical Sciences, Xiamen University, Xiamen 361005, China
1 shared publication
Latest Publications
- Open Access
- 29 October 2023
- Published by MDPI AG in Electronics
- Vol. 12 (21) , 4442
Fault Diagnosis of Vibration Sensors Based on Triage Loss Function-Improved XGBoost
Vibration sensors are prone to bias, drift, and other failures. To avoid misjudgments in state monitoring systems and potential safety accidents caused by vibration sensor failures, it is significant to diagnose the faults of vibration sensors. Existing methods for vibration sensor fault diagnosis are primarily based on Deep Learning, but Extreme Gradient Boosting stands out due to its excellent interpretability, and compared to other ensemble learning algorithms, it boasts superior accuracy and efficiency. Therefore, a vibration sensor fault diagnosis method based on Extreme Gradient Boosting is proposed to diagnose seven common types of faults in vibration sensors. To prevent the model from being overwhelmed by simple negative cases during training, a new loss function named Triage Loss is designed to improve the classifier’s performance. The vibration sensor fault diagnosis has confirmed the efficacy and practicality of the suggested approach. The experimental results indicate that the training of the model done using Triage Loss outperforms the training model done using the default loss function, with a maximum improvement of 5.4% accuracy, 5.45% in the F1-score, and 9.87% in the mean Average Precision under different fault rates.
- 29 October 2023
- Published by MDPI AG in Electronics
- Vol. 12 (21) , 4442
Open AccessFault Diagnosis of Vibration Sensors Based on Triage Loss Function-Improved XGBoost
Vibration sensors are prone to bias, drift, and other failures. To avoid misjudgments in state monitoring systems and potential safety accidents caused by vibration sensor failures, it is significant to diagnose the faults of vibration sensors. Existing methods for vibration sensor fault diagnosis are primarily based on Deep Learning, but Extreme Gradient Boosting stands out due to its excellent interpretability, and compared to other ensemble learning algorithms, it boasts superior accuracy and efficiency. Therefore, a vibration sensor fault diagnosis method based on Extreme Gradient Boosting is proposed to diagnose seven common types of faults in vibration sensors. To prevent the model from being overwhelmed by simple negative cases during training, a new loss function named Triage Loss is designed to improve the classifier’s performance. The vibration sensor fault diagnosis has confirmed the efficacy and practicality of the suggested approach. The experimental results indicate that the training of the model done using Triage Loss outperforms the training model done using the default loss function, with a maximum improvement of 5.4% accuracy, 5.45% in the F1-score, and 9.87% in the mean Average Precision under different fault rates.
- Open Access
Adaptive Fuzzy Modal Matching of Capacitive Micromachined Gyro Electrostatic Controlling
A fuzzy PI controller was utilized to realize the modal matching between a driving and detecting model. A simulation model was built to study electrostatic decoupling controlling technology. The simulation results show that the modal matching can be gained by the fuzzy PI controller. The frequency difference between the driving mode and the detection mode is less than 1 Hz, and the offset of the input DC is smaller than 0.6 V. The optimal proportionality factor and integral coefficient are 1.5 and 20, respectively. The fuzzy PI controlling technology provides a good way for the parameter optimization to gain modal matching of micro gyro, via which the detecting accuracy and stability can be improved greatly.
Open AccessAdaptive Fuzzy Modal Matching of Capacitive Micromachined Gyro Electrostatic Controlling
A fuzzy PI controller was utilized to realize the modal matching between a driving and detecting model. A simulation model was built to study electrostatic decoupling controlling technology. The simulation results show that the modal matching can be gained by the fuzzy PI controller. The frequency difference between the driving mode and the detection mode is less than 1 Hz, and the offset of the input DC is smaller than 0.6 V. The optimal proportionality factor and integral coefficient are 1.5 and 20, respectively. The fuzzy PI controlling technology provides a good way for the parameter optimization to gain modal matching of micro gyro, via which the detecting accuracy and stability can be improved greatly.