HLHuijuan Liang

Huijuan Liang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Huijuan Liang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Partial Discharge Signal Pattern Recognition of Composite Insulation Defects in Cross-Linked Polyethylene Cables

    by Chunxu Qin, Xiaokai Zhu, Pengfei Zhu, Wenjie Lin, Liqiang Liu, Chuanqiang Che, Huijuan Liang, Huichun Hua

    To investigate the pattern recognition of complex defect types in XLPE (cross-linked polyethylene) cable partial discharges and analyze the effectiveness of identifying partial discharge signal patterns, this study employs the variational mode decomposition (VMD) algorithm alongside entropy theories such as power spectrum entropy, fuzzy entropy, and permutation entropy for feature extraction from partial discharge signals of composite insulation defects. The mean power spectrum entropy (PS), mean fuzzy entropy (FU), mean permutation entropy (PE), as well as the permutation entropy values of IMF2 and IMF13 (Pe) are selected as the characteristic quantities for four categories of partial discharge signals associated with composite defects. Six hundred samples are selected from the partial discharge signals of each type of compound defect, amounting to a total of 2400 samples for the four types of compound defects combined. Each sample comprises five feature values, which are compiled into a dataset. A Snake Optimization Algorithm-optimized Support Vector Machine (SO-SVM) model is designed and trained, using the extracted features from cable partial discharge datasets as case examples for recognizing cable partial discharge signals. The identification outcomes from the SO-SVM model are then compared with those from conventional learning models. The results demonstrate that for partial discharge signals of XLPE cable composite insulation defects, the SO-SVM model yields better identification results than traditional learning models. In terms of recognition accuracy, for scratch and water ingress defects, SO-SVM improves by 14.00% over BP (Back Propagation) neural networks, by 5.66% over GA-BP (Genetic Algorithm–Back Propagation), and by 12.50% over SVM (support vector machine). For defects involving metal impurities and scratches, SO-SVM improves by 13.39% over BP, 9.34% over GA-BP, and 12.56% over SVM. For defects with metal impurities and water ingress, SO-SVM shows enhancements of 13.80% over BP, 9.47% over GA-BP, and 13.97% over SVM. Lastly, for defects combining metal impurities, water ingress, and scratches, SO-SVM registers increases of 11.90% over BP, 9.59% over GA-BP, and 12.05% over SVM.


  • Open Access

    Study on Power Frequency Breakdown Characteristics of Nano-TiO2 Modified Transformer Oil under Severe Cold Conditions

    by Chunxu Qin, Yongxiang Huang, Liqiang Liu, Huijuan Liang, Jiafeng Shang, Yunpeng Xue

    With 45# transformer oil as the base fluid, different concentrations of TiO2 nanomodified transformer oil were prepared via the thermal oscillation method. Nanomodified transformer oil with a concentration of 0.01 g/L was selected for evaluation via the breakdown test. Then, 0.01 g/L nanomodified transformer oil and ordinary 45# transformer oil were subjected to the variable control of different moisture contents and different temperatures, and breakdown tests under different types of electrodes were performed within the temperature range of −30 °C to 30 °C. The test results showed the following: Under severe cold conditions, the improvement effect of the breakdown voltage in different temperature ranges was different. Within the temperature range of −30 °C to −10 °C, the enhancement effect could reach 13% to 15%. Within the temperature range of −10 °C to 0 °C, the enhancement effect could reach 8% to 9%. Within the temperature range of 0 °C to 30 °C, the enhancement effect could reach 18% to 21%. Compared with the test results at high water contents, the improvement in the breakdown voltage amplitude of transformer oil by nanomaterials was more obvious at low water contents. In addition, nanomaterials could reduce the dispersion of the breakdown voltage to make the breakdown voltage more stable. Lastly, COMSOL was used to simulate the polarization process of nanoparticles under a uniform electric field and the influence of the trajectory of charged particles in the oil to further analyze the mechanism of the influence of nanoparticles in oil on the breakdown voltage of the oil gap. The simulation results showed that, when the particles were accelerated by the electric field, they moved irregularly. After adding nanoparticles, the charged particles were adsorbed by the nanoparticles when passing through the nanoparticles, which reduced the migration rate of charged particles in the oil. The breakdown voltage of the oil gap increased.