Yiming Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Yiming Ding has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Benfu Zhu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University , Shanxi 710049
1 shared publication- Jianhua Wang
School of Electrical Engineering, Xian Jiaotong University, Xian, China
1 shared publication - Jing Yan
Xi’an Jiaotong University
1 shared publication Junhao Niu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University , Shanxi 710049
1 shared publication- Qinyuan Xian
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University , Shanxi 710049
1 shared publication Ruiqi Liu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University , Shanxi 710049
1 shared publication
Latest Publications
- Open Access
- 1 February 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (2)
Study on the reignition phase and magnetic field simulation of drawn vacuum arc in 126 kV axial magnetic field contacts
With the increase in breaking voltage level, studying the evolution characteristics of reignition of high-current vacuum arc plays an important role to improve the breaking capacity of vacuum circuit breakers. In order to analyze the characteristics of the arc in the reignition phase of 126 kV axial magnetic field (AMF) contacts, drawn vacuum arc experiments were conducted in a detachable vacuum chamber and magnetic field simulations were performed under corresponding conditions. By analyzing the arc images and arc-voltage characteristic of high-current interruption experiments with a pair of 140-mm-diameter cup-type six-slot AMF contact, the arcing reignition process in the second half-wave can be divided into four stages, i.e., reignition stage, disordered movement stage, dispersed arc stage, transition stage, and diffused arc stage. Combined with the magnetic field simulation analysis, at the beginning of the second half-wave just after current zero, the axial magnetic field is weak, resulting in poor control over the arc, while the transverse magnetic field is strong, promoting rotational motion of the arc along the contact surface. In this process, the arc voltage presents significant noise. As the current increases and the axial magnetic field strengthens, the control of the arc gradually improves. The arc transitions from dispersed mode to diffused mode after the current peak. At the same time, cathode spots continuously spread on the contact surface, the arc voltage gradually becomes stable, and the arc extinguishes at the second current zero.
- 1 February 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (2)
Open AccessStudy on the reignition phase and magnetic field simulation of drawn vacuum arc in 126 kV axial magnetic field contacts
With the increase in breaking voltage level, studying the evolution characteristics of reignition of high-current vacuum arc plays an important role to improve the breaking capacity of vacuum circuit breakers. In order to analyze the characteristics of the arc in the reignition phase of 126 kV axial magnetic field (AMF) contacts, drawn vacuum arc experiments were conducted in a detachable vacuum chamber and magnetic field simulations were performed under corresponding conditions. By analyzing the arc images and arc-voltage characteristic of high-current interruption experiments with a pair of 140-mm-diameter cup-type six-slot AMF contact, the arcing reignition process in the second half-wave can be divided into four stages, i.e., reignition stage, disordered movement stage, dispersed arc stage, transition stage, and diffused arc stage. Combined with the magnetic field simulation analysis, at the beginning of the second half-wave just after current zero, the axial magnetic field is weak, resulting in poor control over the arc, while the transverse magnetic field is strong, promoting rotational motion of the arc along the contact surface. In this process, the arc voltage presents significant noise. As the current increases and the axial magnetic field strengthens, the control of the arc gradually improves. The arc transitions from dispersed mode to diffused mode after the current peak. At the same time, cathode spots continuously spread on the contact surface, the arc voltage gradually becomes stable, and the arc extinguishes at the second current zero.
- 28 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
Few-Shot Mechanical Fault Diagnosis for a High-Voltage Circuit Breaker via a Transformer–Convolutional Neural Network and Metric Meta-Learning
High-voltage circuit breakers (HVCBs) are responsible for the vital tasks of control and protection in power grids. Strengthening research on the latent fault diagnosis of HVCBs is vital for improving their reliability in operation. However, current fault diagnosis models are all developed on sufficient samples, which is unrealistic for on-site HVCBs. In addition, these current models were developed on specific datasets and are difficult to generalize to other datasets, which restricts the development of HVCB fault diagnosis. To resolve this issue, a transformer and metric meta-learning (TML) model is proposed for few-shot on-site HVCB diagnosis. First, we propose a hybrid module of a transformer-convolutional neural network to extract fault features, which captures local and global features. Then, fault classification of HVCBs is achieved by using a prototypical network. In the prototypical network, a prototype-rectified classification strategy is introduced to address the bias of intra-class prototypes. Moreover, near-neighbor boundary loss is introduced to correct for intra-class and inter-class distributions of fault features, and the boundary of the class prototype is clarified. The experimental results reveal that the diagnostic accuracy of TML when applied to field HVCBs exceeds 95%, realizing high-precision and robust diagnosis of HVCB faults.
- 28 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
Few-Shot Mechanical Fault Diagnosis for a High-Voltage Circuit Breaker via a Transformer–Convolutional Neural Network and Metric Meta-Learning
High-voltage circuit breakers (HVCBs) are responsible for the vital tasks of control and protection in power grids. Strengthening research on the latent fault diagnosis of HVCBs is vital for improving their reliability in operation. However, current fault diagnosis models are all developed on sufficient samples, which is unrealistic for on-site HVCBs. In addition, these current models were developed on specific datasets and are difficult to generalize to other datasets, which restricts the development of HVCB fault diagnosis. To resolve this issue, a transformer and metric meta-learning (TML) model is proposed for few-shot on-site HVCB diagnosis. First, we propose a hybrid module of a transformer-convolutional neural network to extract fault features, which captures local and global features. Then, fault classification of HVCBs is achieved by using a prototypical network. In the prototypical network, a prototype-rectified classification strategy is introduced to address the bias of intra-class prototypes. Moreover, near-neighbor boundary loss is introduced to correct for intra-class and inter-class distributions of fault features, and the boundary of the class prototype is clarified. The experimental results reveal that the diagnostic accuracy of TML when applied to field HVCBs exceeds 95%, realizing high-precision and robust diagnosis of HVCB faults.