Yuan Tang
Yuan Tang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Ying Xue
School of Electric Power Engineering, South China University of Technology, Guangzhou, China
3 shared publications - Conghuan Yang
Guangzhou Maritime University, Guangzhou, China
2 shared publications - Zhixuan Li
School of Electric Power Engineering, South China University of Technology, Guangzhou, China
2 shared publications Jinjia Zhang
1 shared publicationMeng Chen
1 shared publication- Nan Chen
Department of Electronic, Electrical and Systems Engineering, School of Engineering, University of Birmingham, Birmingham, U.K.
1 shared publication
Latest Publications
- 9 November 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 239
Equivalent system frequency response model with energy storage
- 9 November 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 239
Equivalent system frequency response model with energy storage
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (4) , 2457-2469
Sharing of Primary Frequency Response Using LCC-HVDC
Power systems worldwide are transforming into renewable-dominated ones that require significant grid flexibility. While extensive research has been done on flexibility from the generation or demand side, there is a significant lack of research on studying flexibility from the grid side. Therefore, this paper proposes a primary frequency response sharing strategy using LCC-HVDC for inverter frequency control. Under an inverter frequency event, the proposed method imposes a controlled load change that is proportional to the inverter AC frequency deviation on the rectifier AC network. This in impact activates the primary frequency response from the rectifier side to support the inverter AC frequency (i.e., sharing of primary frequency response). The level of support and the coupled dynamics of rectifier and inverter frequencies are quantified by the developed mathematical model. The model reveals that the inverter load change is affecting the rectifier AC frequency through two cascaded 2 nd order transfer functions. With the developed model and the desired frequency nadirs at both AC systems, the controller parameters of the proposed method are calculated. This ensures that appropriate level of primary frequency response is shared without jeopardizing the frequency performance of rectifier AC system. The effectiveness of the proposed method is demonstrated using a modified four-generator two-area system. Estimation errors of network inertia and droop constants are discussed.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (4) , 2457-2469
Sharing of Primary Frequency Response Using LCC-HVDC
Power systems worldwide are transforming into renewable-dominated ones that require significant grid flexibility. While extensive research has been done on flexibility from the generation or demand side, there is a significant lack of research on studying flexibility from the grid side. Therefore, this paper proposes a primary frequency response sharing strategy using LCC-HVDC for inverter frequency control. Under an inverter frequency event, the proposed method imposes a controlled load change that is proportional to the inverter AC frequency deviation on the rectifier AC network. This in impact activates the primary frequency response from the rectifier side to support the inverter AC frequency (i.e., sharing of primary frequency response). The level of support and the coupled dynamics of rectifier and inverter frequencies are quantified by the developed mathematical model. The model reveals that the inverter load change is affecting the rectifier AC frequency through two cascaded 2 nd order transfer functions. With the developed model and the desired frequency nadirs at both AC systems, the controller parameters of the proposed method are calculated. This ensures that appropriate level of primary frequency response is shared without jeopardizing the frequency performance of rectifier AC system. The effectiveness of the proposed method is demonstrated using a modified four-generator two-area system. Estimation errors of network inertia and droop constants are discussed.
- 29 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (6) , 4287-4301
Adaptive Advancement Angle Compensation for Suppressing Commutation Failures During Rectifier- and Inverter-Fault Recovery
Line-Commutated Converter (LCC) based High-Voltage Direct Current (HVDC) systems are susceptible to commutation failure (CF) during fault recovery not only for faults at inverter, but also for faults at rectifier side. Although the mechanism of CF under each scenario (fault at inverter and fault at rectifier) have been widely discussed, no existing methods can mitigate CFs under both scenarios. This is because the lack of detailed comparative analysis for the root cause of CFs under both scenarios. In this study, it is shown that the essence of CF during fault recovery for faults at both ends are in fact the same – long duration of CC control at both end converters and inability of CEA control to maintain commutation margin after control mode switching during fault recovery. As a result, the inverter cannot maintain a stable operating point during fault recovery. Based on this, an adaptive advancement (beta) angle (ABA) control is proposed that can mitigate CFs during fault recovery for faults at both ends. The proposed control features a direct control of inverter advancement angle that ensures a sufficient commutation margin during recovery. At the same time, the negative impacts of the increase of reactive power consumption are minimized by avoiding the ‘over advancement’ of inverter firing angle. From the V-I trajectory point of view, the trajectory of the system is constrained at the stable operating point during recovery process. PSCAD simulation demonstrates the effectiveness of the proposed method.
- 29 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (6) , 4287-4301
Adaptive Advancement Angle Compensation for Suppressing Commutation Failures During Rectifier- and Inverter-Fault Recovery
Line-Commutated Converter (LCC) based High-Voltage Direct Current (HVDC) systems are susceptible to commutation failure (CF) during fault recovery not only for faults at inverter, but also for faults at rectifier side. Although the mechanism of CF under each scenario (fault at inverter and fault at rectifier) have been widely discussed, no existing methods can mitigate CFs under both scenarios. This is because the lack of detailed comparative analysis for the root cause of CFs under both scenarios. In this study, it is shown that the essence of CF during fault recovery for faults at both ends are in fact the same – long duration of CC control at both end converters and inability of CEA control to maintain commutation margin after control mode switching during fault recovery. As a result, the inverter cannot maintain a stable operating point during fault recovery. Based on this, an adaptive advancement (beta) angle (ABA) control is proposed that can mitigate CFs during fault recovery for faults at both ends. The proposed control features a direct control of inverter advancement angle that ensures a sufficient commutation margin during recovery. At the same time, the negative impacts of the increase of reactive power consumption are minimized by avoiding the ‘over advancement’ of inverter firing angle. From the V-I trajectory point of view, the trajectory of the system is constrained at the stable operating point during recovery process. PSCAD simulation demonstrates the effectiveness of the proposed method.