Xueying Jia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xueying Jia has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Hui Zhang
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
2 shared publications - Junle Yan
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
2 shared publications - Shiyu Jin
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
2 shared publications - Xiaoxi Huang
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
2 shared publications - Haibo Yu
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
1 shared publication - Lei Yang
Central-South Architectural Design Institute Co., Ltd., Wuhan 430061, China
1 shared publication
Latest Publications
- Open Access
- 15 November 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (22) , 15988
Solar Energy Utilization Potential in Urban Residential Blocks: A Case Study of Wuhan, China
In dense, energy-demanding urban areas, the effective utilization of solar energy resources, encompassing building-integrated photovoltaic (BIPV) systems and solar water heating (SWH) systems inside buildings, holds paramount importance for addressing concerns related to carbon emission reduction and the balance of energy supply and demand. This study aimed to examine the interplay between urban residential blocks and their solar energy potential, with the objective of promoting environmentally sustainable development within urban residential areas. The primary focus of this study was the hot summer and cold winter zone of China, which serves as a representative case study. Methodologically, we employed Rhinoceros and Grasshopper (GH) software version GH6.0 tools to simulate the solar radiation potential within residential blocks and translated this information into the potential utilization of BIPV and SWH systems. Subsequently, our focus was directed towards identifying optimal locations for mounting BIPV modules and water heaters on roofs and building façades. The study results revealed the following: (1) The floor area ratio (FAR), building density (BD), average building height (ABH), and space layout (SL) exerted substantial influences on the solar potential of a residential block, with correlations of up to 75%, 71%, 78%, and 50%, respectively, concerning the overall solar potential of the entire plot. (2) It is essential to emphasize that, with regard to the BIPV installation potential, façades account for 80% of the overall residential block potential, whereas rooftops contribute only 20%. Both south- and west-facing façades exhibited a BIPV installation ratio of approximately 34%. (3) In the realm of solar water heating, the potential for installations on building façades accounted for 77% of the total living area of the residential blocks, 23% on the rooftops, and 35% on the south-facing façades. This study furnishes practical guidelines for harnessing the potential of BIPV and SWH systems within residential blocks, thereby contributing to the advancement of sustainable urban development practices.
- 15 November 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (22) , 15988
Open AccessSolar Energy Utilization Potential in Urban Residential Blocks: A Case Study of Wuhan, China
In dense, energy-demanding urban areas, the effective utilization of solar energy resources, encompassing building-integrated photovoltaic (BIPV) systems and solar water heating (SWH) systems inside buildings, holds paramount importance for addressing concerns related to carbon emission reduction and the balance of energy supply and demand. This study aimed to examine the interplay between urban residential blocks and their solar energy potential, with the objective of promoting environmentally sustainable development within urban residential areas. The primary focus of this study was the hot summer and cold winter zone of China, which serves as a representative case study. Methodologically, we employed Rhinoceros and Grasshopper (GH) software version GH6.0 tools to simulate the solar radiation potential within residential blocks and translated this information into the potential utilization of BIPV and SWH systems. Subsequently, our focus was directed towards identifying optimal locations for mounting BIPV modules and water heaters on roofs and building façades. The study results revealed the following: (1) The floor area ratio (FAR), building density (BD), average building height (ABH), and space layout (SL) exerted substantial influences on the solar potential of a residential block, with correlations of up to 75%, 71%, 78%, and 50%, respectively, concerning the overall solar potential of the entire plot. (2) It is essential to emphasize that, with regard to the BIPV installation potential, façades account for 80% of the overall residential block potential, whereas rooftops contribute only 20%. Both south- and west-facing façades exhibited a BIPV installation ratio of approximately 34%. (3) In the realm of solar water heating, the potential for installations on building façades accounted for 77% of the total living area of the residential blocks, 23% on the rooftops, and 35% on the south-facing façades. This study furnishes practical guidelines for harnessing the potential of BIPV and SWH systems within residential blocks, thereby contributing to the advancement of sustainable urban development practices.
- Open Access
- 30 August 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (17) , 13061
Research on Technology System Adaptability of Nearly Zero-Energy Office Buildings in the Hot Summer and Cold Winter Zone of China
In the current context of huge global energy consumption and harsh climatic conditions, the energy efficiency and sustainability of buildings have received much attention. The nearly zero-energy building (nZEB) is a feasible solution for solving the energy crisis in the building sector in recent years, and it is important to study the adaptability of its technology system. However, existing studies have not addressed well the issue of the impact of complex and diverse climates on the technology systems of nZEBs. Secondly, in contrast to residential buildings, nearly zero-energy technology systems for office buildings need to be further developed. This study takes the hot summer and cold winter (HSCW) zone of China as an example and uses numerical simulations and orthogonal experiments to investigate the adaptability of nearly zero-energy office building technology systems under complex and diverse climate conditions. The results show the following: (1) Passive technologies are greatly affected by the complexity and diversity of climates. Optimal envelope thermal parameters tailored to specific zones are identified. Specifically, the optimal level of KWALL in the CT and HSCWC zones is 0.2 W/(m2·K), and the optimal level of KWALL in the HSWWT zone is 0.3 W/(m2·K); the optimal level of KROOF in the CT zone is 0.15 W/(m2·K), and the optimal level of KROOF in the HSCWC and HSWWT zones is 0.25 W/(m2·K); (2) Active technologies do not mainly receive the influence of the complexity and diversity of climates, and ED, HR, and TS measures should be adopted for office buildings; (3) The rational utilization of renewable energy is influenced by local resource conditions. This study evaluates the adaptability of GSHP, ASHP, and BIPV technologies. To better meet the requirements of nearly zero-energy office buildings, it is recommended to adopt GSHP for the CT zone and ASHP for the HCWWT zone. This study will be helpful for the development of nearly zero-energy office building technology systems in other complex and diverse climatic zones.
- 30 August 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (17) , 13061
Open AccessResearch on Technology System Adaptability of Nearly Zero-Energy Office Buildings in the Hot Summer and Cold Winter Zone of China
In the current context of huge global energy consumption and harsh climatic conditions, the energy efficiency and sustainability of buildings have received much attention. The nearly zero-energy building (nZEB) is a feasible solution for solving the energy crisis in the building sector in recent years, and it is important to study the adaptability of its technology system. However, existing studies have not addressed well the issue of the impact of complex and diverse climates on the technology systems of nZEBs. Secondly, in contrast to residential buildings, nearly zero-energy technology systems for office buildings need to be further developed. This study takes the hot summer and cold winter (HSCW) zone of China as an example and uses numerical simulations and orthogonal experiments to investigate the adaptability of nearly zero-energy office building technology systems under complex and diverse climate conditions. The results show the following: (1) Passive technologies are greatly affected by the complexity and diversity of climates. Optimal envelope thermal parameters tailored to specific zones are identified. Specifically, the optimal level of KWALL in the CT and HSCWC zones is 0.2 W/(m2·K), and the optimal level of KWALL in the HSWWT zone is 0.3 W/(m2·K); the optimal level of KROOF in the CT zone is 0.15 W/(m2·K), and the optimal level of KROOF in the HSCWC and HSWWT zones is 0.25 W/(m2·K); (2) Active technologies do not mainly receive the influence of the complexity and diversity of climates, and ED, HR, and TS measures should be adopted for office buildings; (3) The rational utilization of renewable energy is influenced by local resource conditions. This study evaluates the adaptability of GSHP, ASHP, and BIPV technologies. To better meet the requirements of nearly zero-energy office buildings, it is recommended to adopt GSHP for the CT zone and ASHP for the HCWWT zone. This study will be helpful for the development of nearly zero-energy office building technology systems in other complex and diverse climatic zones.