Shiyu Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shiyu Jin has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Hui Zhang
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
4 shared publications - Xiaoxi Huang
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
4 shared publications - Junle Yan
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
3 shared publications - Haibo Yu
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
2 shared publications - Xueying Jia
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
2 shared publications - Zhengwei Wang
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
2 shared publications
Latest Publications
- Open Access
An Estimation of the Available Spatial Intensity of Solar Energy in Urban Blocks in Wuhan, China
Urban form is an important factor affecting urban energy. However, the design of urban form and energy mostly belong to two separate disciplines and fields, and urban energy planning research rarely considers their mutual relationship. The available space intensity (ASI) of solar energy is formed on the basis of energy planning and urban design; the objective of this research is to evaluate the impact of urban form on the ASI of solar energy and to propose strategies for planning of the space that is available for solar energy so as to improve the efficiency of urban energy utilization and achieve sustainable urban development. Methodologically, this study firstly proposes a model to quantify the ASI of solar energy using three indicators: solar radiation intensity (SRI), solar installation intensity (SII), and solar generation intensity (SEGI). Then, we quantitatively calculate the solar ASI of nine types of typical urban blocks in a sub-center of Wuhan City, Nanhu. Correlation analysis and multiple linear regression analysis are then used to analyze the correlation between the form indicators and solar ASI, as well as the degree of influence. The results show that the differences in SRI, SII, and SEGI amongst the nine types of city blocks were as high as 114.61%, 162.50%, and 61.01%. The solar ASI was mainly affected by three form indicators: the building coverage ratio, the average building height, and the volume-to-area ratio. Reducing the building coverage ratio and increasing vertical development at the same time can effectively improve the ASI of solar energy. The results of this study and the established method provide an important reference and rapid calculation tool for urban energy planning and design, reducing the data and time usually required for solar analysis at the block scale.
Open AccessAn Estimation of the Available Spatial Intensity of Solar Energy in Urban Blocks in Wuhan, China
Urban form is an important factor affecting urban energy. However, the design of urban form and energy mostly belong to two separate disciplines and fields, and urban energy planning research rarely considers their mutual relationship. The available space intensity (ASI) of solar energy is formed on the basis of energy planning and urban design; the objective of this research is to evaluate the impact of urban form on the ASI of solar energy and to propose strategies for planning of the space that is available for solar energy so as to improve the efficiency of urban energy utilization and achieve sustainable urban development. Methodologically, this study firstly proposes a model to quantify the ASI of solar energy using three indicators: solar radiation intensity (SRI), solar installation intensity (SII), and solar generation intensity (SEGI). Then, we quantitatively calculate the solar ASI of nine types of typical urban blocks in a sub-center of Wuhan City, Nanhu. Correlation analysis and multiple linear regression analysis are then used to analyze the correlation between the form indicators and solar ASI, as well as the degree of influence. The results show that the differences in SRI, SII, and SEGI amongst the nine types of city blocks were as high as 114.61%, 162.50%, and 61.01%. The solar ASI was mainly affected by three form indicators: the building coverage ratio, the average building height, and the volume-to-area ratio. Reducing the building coverage ratio and increasing vertical development at the same time can effectively improve the ASI of solar energy. The results of this study and the established method provide an important reference and rapid calculation tool for urban energy planning and design, reducing the data and time usually required for solar analysis at the block scale.
- Open Access
- 15 November 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (22) , 15988
Solar Energy Utilization Potential in Urban Residential Blocks: A Case Study of Wuhan, China
In dense, energy-demanding urban areas, the effective utilization of solar energy resources, encompassing building-integrated photovoltaic (BIPV) systems and solar water heating (SWH) systems inside buildings, holds paramount importance for addressing concerns related to carbon emission reduction and the balance of energy supply and demand. This study aimed to examine the interplay between urban residential blocks and their solar energy potential, with the objective of promoting environmentally sustainable development within urban residential areas. The primary focus of this study was the hot summer and cold winter zone of China, which serves as a representative case study. Methodologically, we employed Rhinoceros and Grasshopper (GH) software version GH6.0 tools to simulate the solar radiation potential within residential blocks and translated this information into the potential utilization of BIPV and SWH systems. Subsequently, our focus was directed towards identifying optimal locations for mounting BIPV modules and water heaters on roofs and building façades. The study results revealed the following: (1) The floor area ratio (FAR), building density (BD), average building height (ABH), and space layout (SL) exerted substantial influences on the solar potential of a residential block, with correlations of up to 75%, 71%, 78%, and 50%, respectively, concerning the overall solar potential of the entire plot. (2) It is essential to emphasize that, with regard to the BIPV installation potential, façades account for 80% of the overall residential block potential, whereas rooftops contribute only 20%. Both south- and west-facing façades exhibited a BIPV installation ratio of approximately 34%. (3) In the realm of solar water heating, the potential for installations on building façades accounted for 77% of the total living area of the residential blocks, 23% on the rooftops, and 35% on the south-facing façades. This study furnishes practical guidelines for harnessing the potential of BIPV and SWH systems within residential blocks, thereby contributing to the advancement of sustainable urban development practices.
- 15 November 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (22) , 15988
Open AccessSolar Energy Utilization Potential in Urban Residential Blocks: A Case Study of Wuhan, China
In dense, energy-demanding urban areas, the effective utilization of solar energy resources, encompassing building-integrated photovoltaic (BIPV) systems and solar water heating (SWH) systems inside buildings, holds paramount importance for addressing concerns related to carbon emission reduction and the balance of energy supply and demand. This study aimed to examine the interplay between urban residential blocks and their solar energy potential, with the objective of promoting environmentally sustainable development within urban residential areas. The primary focus of this study was the hot summer and cold winter zone of China, which serves as a representative case study. Methodologically, we employed Rhinoceros and Grasshopper (GH) software version GH6.0 tools to simulate the solar radiation potential within residential blocks and translated this information into the potential utilization of BIPV and SWH systems. Subsequently, our focus was directed towards identifying optimal locations for mounting BIPV modules and water heaters on roofs and building façades. The study results revealed the following: (1) The floor area ratio (FAR), building density (BD), average building height (ABH), and space layout (SL) exerted substantial influences on the solar potential of a residential block, with correlations of up to 75%, 71%, 78%, and 50%, respectively, concerning the overall solar potential of the entire plot. (2) It is essential to emphasize that, with regard to the BIPV installation potential, façades account for 80% of the overall residential block potential, whereas rooftops contribute only 20%. Both south- and west-facing façades exhibited a BIPV installation ratio of approximately 34%. (3) In the realm of solar water heating, the potential for installations on building façades accounted for 77% of the total living area of the residential blocks, 23% on the rooftops, and 35% on the south-facing façades. This study furnishes practical guidelines for harnessing the potential of BIPV and SWH systems within residential blocks, thereby contributing to the advancement of sustainable urban development practices.
- Open Access
- 26 October 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (21) , 15307
Study on the Influence of the Energy Intensity of Residential District Layout on Neighborhood Buildings
Numerous prior studies have substantiated the influence of residential layout on building energy consumption; however, their principal emphasis has predominantly been on urban and neighborhood contexts. Nevertheless, research conducted at the cluster scale has the potential to augment the well-being of neighboring communities and render the objective of a reduction in energy consumption more pertinent to residents’ daily lives. Furthermore, there is a shortage of more robust metrics capable of quantifying the degree of mutual shading among individual buildings within residential neighborhoods. This shading factor constitutes a pivotal element impacting the energy consumption of individual structures. This study utilizes the VirVil-HTB2 tool to calculate solar radiation intensity for individual buildings, serving as a shading metric. Correlation and linear regression analyses are employed to quantify the causal relationship, allowing us to investigate the impact of residential complex layouts on the energy efficiency of individual buildings. The findings of this study indicate that solar radiation serves as a precise metric for gauging shading intensity among buildings, and building energy consumption exhibits a distinct block-like distribution pattern within the residential complex. Furthermore, through an analysis of the level of inter-building shading and a judicious optimization of the layout, it is feasible to achieve a reduction of up to 4.03% in heating energy consumption and a maximum reduction of 4.39% in cooling energy consumption.
- 26 October 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (21) , 15307
Open AccessStudy on the Influence of the Energy Intensity of Residential District Layout on Neighborhood Buildings
Numerous prior studies have substantiated the influence of residential layout on building energy consumption; however, their principal emphasis has predominantly been on urban and neighborhood contexts. Nevertheless, research conducted at the cluster scale has the potential to augment the well-being of neighboring communities and render the objective of a reduction in energy consumption more pertinent to residents’ daily lives. Furthermore, there is a shortage of more robust metrics capable of quantifying the degree of mutual shading among individual buildings within residential neighborhoods. This shading factor constitutes a pivotal element impacting the energy consumption of individual structures. This study utilizes the VirVil-HTB2 tool to calculate solar radiation intensity for individual buildings, serving as a shading metric. Correlation and linear regression analyses are employed to quantify the causal relationship, allowing us to investigate the impact of residential complex layouts on the energy efficiency of individual buildings. The findings of this study indicate that solar radiation serves as a precise metric for gauging shading intensity among buildings, and building energy consumption exhibits a distinct block-like distribution pattern within the residential complex. Furthermore, through an analysis of the level of inter-building shading and a judicious optimization of the layout, it is feasible to achieve a reduction of up to 4.03% in heating energy consumption and a maximum reduction of 4.39% in cooling energy consumption.
- Open Access
- 30 August 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (17) , 13061
Research on Technology System Adaptability of Nearly Zero-Energy Office Buildings in the Hot Summer and Cold Winter Zone of China
In the current context of huge global energy consumption and harsh climatic conditions, the energy efficiency and sustainability of buildings have received much attention. The nearly zero-energy building (nZEB) is a feasible solution for solving the energy crisis in the building sector in recent years, and it is important to study the adaptability of its technology system. However, existing studies have not addressed well the issue of the impact of complex and diverse climates on the technology systems of nZEBs. Secondly, in contrast to residential buildings, nearly zero-energy technology systems for office buildings need to be further developed. This study takes the hot summer and cold winter (HSCW) zone of China as an example and uses numerical simulations and orthogonal experiments to investigate the adaptability of nearly zero-energy office building technology systems under complex and diverse climate conditions. The results show the following: (1) Passive technologies are greatly affected by the complexity and diversity of climates. Optimal envelope thermal parameters tailored to specific zones are identified. Specifically, the optimal level of KWALL in the CT and HSCWC zones is 0.2 W/(m2·K), and the optimal level of KWALL in the HSWWT zone is 0.3 W/(m2·K); the optimal level of KROOF in the CT zone is 0.15 W/(m2·K), and the optimal level of KROOF in the HSCWC and HSWWT zones is 0.25 W/(m2·K); (2) Active technologies do not mainly receive the influence of the complexity and diversity of climates, and ED, HR, and TS measures should be adopted for office buildings; (3) The rational utilization of renewable energy is influenced by local resource conditions. This study evaluates the adaptability of GSHP, ASHP, and BIPV technologies. To better meet the requirements of nearly zero-energy office buildings, it is recommended to adopt GSHP for the CT zone and ASHP for the HCWWT zone. This study will be helpful for the development of nearly zero-energy office building technology systems in other complex and diverse climatic zones.
- 30 August 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (17) , 13061
Open AccessResearch on Technology System Adaptability of Nearly Zero-Energy Office Buildings in the Hot Summer and Cold Winter Zone of China
In the current context of huge global energy consumption and harsh climatic conditions, the energy efficiency and sustainability of buildings have received much attention. The nearly zero-energy building (nZEB) is a feasible solution for solving the energy crisis in the building sector in recent years, and it is important to study the adaptability of its technology system. However, existing studies have not addressed well the issue of the impact of complex and diverse climates on the technology systems of nZEBs. Secondly, in contrast to residential buildings, nearly zero-energy technology systems for office buildings need to be further developed. This study takes the hot summer and cold winter (HSCW) zone of China as an example and uses numerical simulations and orthogonal experiments to investigate the adaptability of nearly zero-energy office building technology systems under complex and diverse climate conditions. The results show the following: (1) Passive technologies are greatly affected by the complexity and diversity of climates. Optimal envelope thermal parameters tailored to specific zones are identified. Specifically, the optimal level of KWALL in the CT and HSCWC zones is 0.2 W/(m2·K), and the optimal level of KWALL in the HSWWT zone is 0.3 W/(m2·K); the optimal level of KROOF in the CT zone is 0.15 W/(m2·K), and the optimal level of KROOF in the HSCWC and HSWWT zones is 0.25 W/(m2·K); (2) Active technologies do not mainly receive the influence of the complexity and diversity of climates, and ED, HR, and TS measures should be adopted for office buildings; (3) The rational utilization of renewable energy is influenced by local resource conditions. This study evaluates the adaptability of GSHP, ASHP, and BIPV technologies. To better meet the requirements of nearly zero-energy office buildings, it is recommended to adopt GSHP for the CT zone and ASHP for the HCWWT zone. This study will be helpful for the development of nearly zero-energy office building technology systems in other complex and diverse climatic zones.