Chenshuang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chenshuang Zhang has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Junle Qu
Shenzhen University
4 shared publications - Liwei Liu
Shenzhen University
3 shared publications - Bin Yu
Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
2 shared publications - Danying Lin
Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering
2 shared publications Fangrui Lin
State Key Laboratory of Radio Frequency Heterogeneous Integration (Shenzhen University) and Key Laboratory of Optoelectronic Devices and Systems, College of Physics and Optoelectronic Engineering, Shenzhen University 1 , Shenzhen 518060
2 shared publications- Jia Li
Key Laboratory of Optoelectronic Devices and Systems College of Physics and Optoelectronic Engineering State Key Laboratory of Radio Frequency Heterogeneous Integration (Shenzhen University) Shenzhen University Shenzhen China
2 shared publications
Latest Publications
- 8 October 2026
- Published by American Association for Cancer Research (AACR) in Cancer Research
ANXA1 Promotes Endoplasmic Reticulum–Mitochondria Calcium Coupling to Sustain Lenvatinib Resistance in Hepatocellular Carcinoma
Lenvatinib is the most widely used first-line treatment for advanced hepatocellular carcinoma (HCC). Nevertheless, drug resistance remains a major clinical challenge, highlighting the need to identify the underlying mechanistic drivers. Here, we identified a role for annexin A1 (ANXA1) in promoting lenvatinib resistance by supporting endoplasmic reticulum (ER)–mitochondria communication. Live-cell structured illumination microscopy revealed that ANXA1 deficiency induced the dissociation of ER–mitochondria contact sites (ERMCS), and Ca2+ kinetic analysis revealed that ANXA1 enhanced mitochondrial Ca2+ coupling. ANXA1 promoted ERMCS by directly binding the ER–mitochondria Ca2+ transfer tethers GRP75 and ITPR1 and promoting their interaction. Functionally, ANXA1 sustained oxidative phosphorylation following lenvatinib treatment and promoted cell survival. We further found that ANXA1 RNA stability was governed by an 8-oxoguanine modification–mediated ROS feedback loop. Therapeutically, photoacoustic imaging–guided in vivo analyses demonstrated that targeting this epigenetic–organelle communication feedback loop resensitized HCC to lenvatinib treatment, inhibiting peritumoral angiogenesis and improving the intratumoral hypoxic microenvironment. These findings uncover ERMCS formation as a driver of lenvatinib resistance in HCC, establishing a potential therapeutic strategy for targeting organelle communication to reverse drug resistance.
- 8 October 2026
- Published by American Association for Cancer Research (AACR) in Cancer Research
ANXA1 Promotes Endoplasmic Reticulum–Mitochondria Calcium Coupling to Sustain Lenvatinib Resistance in Hepatocellular Carcinoma
Lenvatinib is the most widely used first-line treatment for advanced hepatocellular carcinoma (HCC). Nevertheless, drug resistance remains a major clinical challenge, highlighting the need to identify the underlying mechanistic drivers. Here, we identified a role for annexin A1 (ANXA1) in promoting lenvatinib resistance by supporting endoplasmic reticulum (ER)–mitochondria communication. Live-cell structured illumination microscopy revealed that ANXA1 deficiency induced the dissociation of ER–mitochondria contact sites (ERMCS), and Ca2+ kinetic analysis revealed that ANXA1 enhanced mitochondrial Ca2+ coupling. ANXA1 promoted ERMCS by directly binding the ER–mitochondria Ca2+ transfer tethers GRP75 and ITPR1 and promoting their interaction. Functionally, ANXA1 sustained oxidative phosphorylation following lenvatinib treatment and promoted cell survival. We further found that ANXA1 RNA stability was governed by an 8-oxoguanine modification–mediated ROS feedback loop. Therapeutically, photoacoustic imaging–guided in vivo analyses demonstrated that targeting this epigenetic–organelle communication feedback loop resensitized HCC to lenvatinib treatment, inhibiting peritumoral angiogenesis and improving the intratumoral hypoxic microenvironment. These findings uncover ERMCS formation as a driver of lenvatinib resistance in HCC, establishing a potential therapeutic strategy for targeting organelle communication to reverse drug resistance.
- 7 August 2026
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 13  (3)
Applications of fluorescence lifetime imaging microscopy in brain disease research: A comprehensive review
Neurodegenerative diseases (NDs) and brain tumors constitute two of the most devastating classes of brain disorders, imposing severe and growing burdens on global public health. Fluorescence lifetime imaging microscopy (FLIM) represents a powerful, environment-sensitive analytical tool that enables quantitative interrogation of molecular excited-state decay dynamics, independent of fluorophore concentration. This technique offers unprecedented insights into diverse biological processes, including metabolic reprogramming, protein–protein interactions, and intracellular microenvironmental dynamics, thereby providing a unique mechanistic window into the pathogenesis and early diagnosis of brain diseases. This review provides a comprehensive synthesis of state-of-the-art applications of FLIM in neuropathological research. We first introduce the fundamental principles and major detection modalities of FLIM. We then highlight key advances in applying FLIM to the study of representative brain diseases, with a focus on probing pathological protein aggregation in NDs and delineating tumor margins in brain malignancies. Finally, we critically evaluate current limitations and outline promising future directions to advance FLIM-based technologies toward clinical translation in brain health care.
- 7 August 2026
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 13  (3)
Applications of fluorescence lifetime imaging microscopy in brain disease research: A comprehensive review
Neurodegenerative diseases (NDs) and brain tumors constitute two of the most devastating classes of brain disorders, imposing severe and growing burdens on global public health. Fluorescence lifetime imaging microscopy (FLIM) represents a powerful, environment-sensitive analytical tool that enables quantitative interrogation of molecular excited-state decay dynamics, independent of fluorophore concentration. This technique offers unprecedented insights into diverse biological processes, including metabolic reprogramming, protein–protein interactions, and intracellular microenvironmental dynamics, thereby providing a unique mechanistic window into the pathogenesis and early diagnosis of brain diseases. This review provides a comprehensive synthesis of state-of-the-art applications of FLIM in neuropathological research. We first introduce the fundamental principles and major detection modalities of FLIM. We then highlight key advances in applying FLIM to the study of representative brain diseases, with a focus on probing pathological protein aggregation in NDs and delineating tumor margins in brain malignancies. Finally, we critically evaluate current limitations and outline promising future directions to advance FLIM-based technologies toward clinical translation in brain health care.
- 2 January 2026
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 13  (1)
Advances in fluorescence lifetime imaging microscopy: Techniques and biomedical applications
Fluorescence lifetime imaging microscopy (FLIM) has emerged as a powerful biomedical imaging technique for the quantitative visualization of intricate molecular and cellular processes. Significant advancements in photonics, sensor technology, data acquisition systems, and computational algorithms have substantially improved the spatiotemporal resolution, imaging depth, and analytical throughput of FLIM. These developments have diversified FLIM methodologies, including time-domain techniques such as time-correlated single-photon counting (TCSPC), time-gated detection, streak cameras, and direct pulse-recording systems, as well as frequency-domain approaches. Concurrently, FLIM has been successfully integrated with advanced imaging modalities, such as multiphoton microscopy, light-sheet imaging, and endoscopy. This review provides a comprehensive synthesis of advanced FLIM technologies. We present in-depth discussions on the principles of lifetime quantification, recent innovations in hardware and algorithms for lifetime recovery, and state-of-the-art strategies to accelerate imaging speed while maintaining resolution and sensitivity. Moreover, we explore FLIM's unique capability to investigate dynamic metabolic states through endogenous autofluorescent cofactors, quantify physicochemical parameters of the cellular microenvironment (e.g., pH, polarity, viscosity, and ion concentrations), and facilitate the diagnosis of diseases such as cancer and neurodegeneration. Finally, we discuss future directions for FLIM development, including integration with deep learning, miniaturized hardware for point-of-care applications, and real-time clinical translation. Collectively, this review aims to provide researchers, clinicians, and engineers with both fundamental knowledge and forward-looking perspectives to further unlock the potential of FLIM in advancing biomedical science.
- 2 January 2026
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 13  (1)
Advances in fluorescence lifetime imaging microscopy: Techniques and biomedical applications
Fluorescence lifetime imaging microscopy (FLIM) has emerged as a powerful biomedical imaging technique for the quantitative visualization of intricate molecular and cellular processes. Significant advancements in photonics, sensor technology, data acquisition systems, and computational algorithms have substantially improved the spatiotemporal resolution, imaging depth, and analytical throughput of FLIM. These developments have diversified FLIM methodologies, including time-domain techniques such as time-correlated single-photon counting (TCSPC), time-gated detection, streak cameras, and direct pulse-recording systems, as well as frequency-domain approaches. Concurrently, FLIM has been successfully integrated with advanced imaging modalities, such as multiphoton microscopy, light-sheet imaging, and endoscopy. This review provides a comprehensive synthesis of advanced FLIM technologies. We present in-depth discussions on the principles of lifetime quantification, recent innovations in hardware and algorithms for lifetime recovery, and state-of-the-art strategies to accelerate imaging speed while maintaining resolution and sensitivity. Moreover, we explore FLIM's unique capability to investigate dynamic metabolic states through endogenous autofluorescent cofactors, quantify physicochemical parameters of the cellular microenvironment (e.g., pH, polarity, viscosity, and ion concentrations), and facilitate the diagnosis of diseases such as cancer and neurodegeneration. Finally, we discuss future directions for FLIM development, including integration with deep learning, miniaturized hardware for point-of-care applications, and real-time clinical translation. Collectively, this review aims to provide researchers, clinicians, and engineers with both fundamental knowledge and forward-looking perspectives to further unlock the potential of FLIM in advancing biomedical science.
- 16 July 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96  (30) , 12286-12295
Research of Pulmonary Fibrosis Lesions Based on FLIM and SHG Imaging Microscopy
Two-photon fluorescence lifetime microscopy (TP-FLIM) is a powerful quantitative imaging technique that characterizes and analyzes the structure and function of biological samples through a combination of intensity and lifetime imaging. Because TP-FLIM is independent of the fluorescence signal intensity and the fluorophore concentration, it is widely used in high-throughput, high-content drug screening and clinical diagnostics. Second harmonic generation (SHG) imaging technology has the advantages of high spatial resolution and imaging depth inherent to nonlinear optical imaging. Second harmonics often appear in noncentrosymmetric structures. Collagen tissue in biological organisms is a good example of these structures, showing strong harmonic effects. Therefore, SHG has been widely used for imaging of specific tissue structure imaging. TP-FLIM technology is highly sensitive for quantitatively detecting changes in microenvironments. The objective of this study is to examine pathological pulmonary fibrosis slices using a combined approach of TP-FLIM and SHG technology. The fluorescence lifetime data of pulmonary collagen fibers are analyzed by using phasor plot analysis methods, and normal collagen fibers and fibrotic collagen fibers are distinguished by calculating the aspect ratio from the SHG images formed by the collagen fibers. Our study provides a new method for a deeper understanding of the pathological mechanisms and clinical diagnosis of pulmonary fibrosis and other collagen fiber-related disorders.
- 16 July 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96  (30) , 12286-12295
Research of Pulmonary Fibrosis Lesions Based on FLIM and SHG Imaging Microscopy
Two-photon fluorescence lifetime microscopy (TP-FLIM) is a powerful quantitative imaging technique that characterizes and analyzes the structure and function of biological samples through a combination of intensity and lifetime imaging. Because TP-FLIM is independent of the fluorescence signal intensity and the fluorophore concentration, it is widely used in high-throughput, high-content drug screening and clinical diagnostics. Second harmonic generation (SHG) imaging technology has the advantages of high spatial resolution and imaging depth inherent to nonlinear optical imaging. Second harmonics often appear in noncentrosymmetric structures. Collagen tissue in biological organisms is a good example of these structures, showing strong harmonic effects. Therefore, SHG has been widely used for imaging of specific tissue structure imaging. TP-FLIM technology is highly sensitive for quantitatively detecting changes in microenvironments. The objective of this study is to examine pathological pulmonary fibrosis slices using a combined approach of TP-FLIM and SHG technology. The fluorescence lifetime data of pulmonary collagen fibers are analyzed by using phasor plot analysis methods, and normal collagen fibers and fibrotic collagen fibers are distinguished by calculating the aspect ratio from the SHG images formed by the collagen fibers. Our study provides a new method for a deeper understanding of the pathological mechanisms and clinical diagnosis of pulmonary fibrosis and other collagen fiber-related disorders.
- 29 August 2023
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 23  (17) , 7975-7982
Super-Resolution Second-Harmonic Generation Imaging with Multifocal Structured Illumination Microscopy
Second-harmonic generation (SHG) is a noninvasive imaging technique that enables the exploration of physiological structures without the use of an exogenous label. However, traditional SHG imaging is limited by optical diffraction, which restricts the spatial resolution. To break this limitation, we developed a novel approach called multifocal structured illumination microscopy-SHG (MSIM-SHG). By combination of SHG with MSIM, SHG-based super-resolution imaging of material molecules can be achieved, and this SHG super-resolution imaging has a wide range of applications for biological tissues and cells. MSIM-SHG achieved a lateral full width at half-maximum (fwhm) of 147 ± 13 nm and an axial fwhm of 493 ± 47 nm by imaging zinc oxide (ZnO) particles. Furthermore, MSIM-SHG was utilized to quantify collagen fiber alignment in various tissues such as the ovary, muscle, heart, kidney, and cartilage, demonstrating its feasibility for identifying collagen characteristics. MSIM-SHG has potential as a powerful tool for clinical diagnosis and biological research.
- 29 August 2023
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 23  (17) , 7975-7982
Super-Resolution Second-Harmonic Generation Imaging with Multifocal Structured Illumination Microscopy
Second-harmonic generation (SHG) is a noninvasive imaging technique that enables the exploration of physiological structures without the use of an exogenous label. However, traditional SHG imaging is limited by optical diffraction, which restricts the spatial resolution. To break this limitation, we developed a novel approach called multifocal structured illumination microscopy-SHG (MSIM-SHG). By combination of SHG with MSIM, SHG-based super-resolution imaging of material molecules can be achieved, and this SHG super-resolution imaging has a wide range of applications for biological tissues and cells. MSIM-SHG achieved a lateral full width at half-maximum (fwhm) of 147 ± 13 nm and an axial fwhm of 493 ± 47 nm by imaging zinc oxide (ZnO) particles. Furthermore, MSIM-SHG was utilized to quantify collagen fiber alignment in various tissues such as the ovary, muscle, heart, kidney, and cartilage, demonstrating its feasibility for identifying collagen characteristics. MSIM-SHG has potential as a powerful tool for clinical diagnosis and biological research.
- 21 February 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 28  (2) , 330-337
Automated ExEm-spFRET Microscope
Excitation–emission-spectral unmixing-based fluorescence resonance energy transfer (ExEm-spFRET) microscopy exhibits excellent robustness in living cells. We here develop an automatic ExEm-spFRET microscope with 3.04 s of time resolution for a quantitative FRET imaging. The user-friendly interface software has been designed to operate in two modes: administrator and user. Automatic background recognition, subtraction, and cell segmentation were integrated into the software, which enables FRET calibration or measurement in a one-click operation manner. In administrator mode, both correction factors and spectral fingerprints are only calibrated periodically for a stable system. In user mode, quantitative ExEm-spFRET imaging is directly implemented for FRET samples. We implemented quantitative ExEm-spFRET imaging for living cells expressing different tandem constructs (C80Y, C40Y, C10Y, and C4Y, respectively) and obtained consistent results for at least 3 months, demonstrating the stability of our microscope. Next, we investigated Bcl-xL-Bad interaction by using ExEm-spFRET imaging and FRET two-hybrid assay and found that the Bcl-xL-Bad complexes exist mainly in Bad-Bcl-xL trimers in healthy cells and Bad-Bcl-xL2 trimers in apoptotic cells. We also performed time-lapse FRET imaging on our system for living cells expressing Yellow Cameleon 3.6 (YC3.6) to monitor ionomycin-induced rapid extracellular Ca2+ influx with a time interval of 5 s for total 250 s.
- 21 February 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 28  (2) , 330-337
Automated ExEm-spFRET Microscope
Excitation–emission-spectral unmixing-based fluorescence resonance energy transfer (ExEm-spFRET) microscopy exhibits excellent robustness in living cells. We here develop an automatic ExEm-spFRET microscope with 3.04 s of time resolution for a quantitative FRET imaging. The user-friendly interface software has been designed to operate in two modes: administrator and user. Automatic background recognition, subtraction, and cell segmentation were integrated into the software, which enables FRET calibration or measurement in a one-click operation manner. In administrator mode, both correction factors and spectral fingerprints are only calibrated periodically for a stable system. In user mode, quantitative ExEm-spFRET imaging is directly implemented for FRET samples. We implemented quantitative ExEm-spFRET imaging for living cells expressing different tandem constructs (C80Y, C40Y, C10Y, and C4Y, respectively) and obtained consistent results for at least 3 months, demonstrating the stability of our microscope. Next, we investigated Bcl-xL-Bad interaction by using ExEm-spFRET imaging and FRET two-hybrid assay and found that the Bcl-xL-Bad complexes exist mainly in Bad-Bcl-xL trimers in healthy cells and Bad-Bcl-xL2 trimers in apoptotic cells. We also performed time-lapse FRET imaging on our system for living cells expressing Yellow Cameleon 3.6 (YC3.6) to monitor ionomycin-induced rapid extracellular Ca2+ influx with a time interval of 5 s for total 250 s.
- Open Access
- 22 November 2021
- Published by Frontiers Media SA in Frontiers in Chemistry
- Vol. 9, 795767
Corrigendum: Super-Resolution Microscopy: Shedding New Light on In Vivo Imaging
Corrigendum: Super-Resolution Microscopy: Shedding New Light on In Vivo Imaging
- 22 November 2021
- Published by Frontiers Media SA in Frontiers in Chemistry
- Vol. 9, 795767
Open AccessCorrigendum: Super-Resolution Microscopy: Shedding New Light on In Vivo Imaging
Corrigendum: Super-Resolution Microscopy: Shedding New Light on In Vivo Imaging
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2018, 2555-2558
Bidirectional Recurrent Neural Network And Convolutional Neural Network (BiRCNN) For ECG Beat Classification
We propose a novel electrocardiogram (ECG) beat classification algorithm using a combination of Bidirectional Recurrent Neural Network (BiRNN) and Convolutional Neural Network (CNN) named as BiRCNN. Our model is an end-to-end model. The morphological features of each ECG beat is extracted by CNN. Then the features of each beat are considered in the context via BiRNN. The assessment on MIT-BIH Arrhythmia Database (MITDB) resulted in a sensitivity of 98.7% and a positive predictivity of 96.4% on average for the VEB class. For the SVEB class, the sensitivity was 92.8%, which was an over 6% promotion compared with the state-of-the-art method, and the positive predictivity was 81.9% on average. The results demonstrate the superior classification performance of our method.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2018, 2555-2558
Bidirectional Recurrent Neural Network And Convolutional Neural Network (BiRCNN) For ECG Beat Classification
We propose a novel electrocardiogram (ECG) beat classification algorithm using a combination of Bidirectional Recurrent Neural Network (BiRNN) and Convolutional Neural Network (CNN) named as BiRCNN. Our model is an end-to-end model. The morphological features of each ECG beat is extracted by CNN. Then the features of each beat are considered in the context via BiRNN. The assessment on MIT-BIH Arrhythmia Database (MITDB) resulted in a sensitivity of 98.7% and a positive predictivity of 96.4% on average for the VEB class. For the SVEB class, the sensitivity was 92.8%, which was an over 6% promotion compared with the state-of-the-art method, and the positive predictivity was 81.9% on average. The results demonstrate the superior classification performance of our method.