Stephen Bawden
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stephen Bawden has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Guruprasad Padur Aithal
Department of Hepatology Nottingham University Hospitals NHS Trust Nottingham UK
4 shared publications - Ian Andrew Macdonald
MRC Versus Arthritis Centre for Musculoskeletal Ageing Research, David Greenfield Human Physiology Unit, School of Life Sciences, University of Nottingham, Queen's Medical Centre, Nottingham, UK; National Institute for Health Research (NIHR) Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and University of Nottingham, Nottingham, UK
2 shared publications K. Hunter
Unilever Discover, Unilever, Colworth, UK
2 shared publications- Luca Marciani
NIHR Nottingham Biomedical Research Centre at the Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, UK
2 shared publications - Mary Charlotte Stephenson
Sir Peter Mansfield Magnetic Resonance Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
2 shared publications - Penny A. Gowland
Sir Peter Mansfield Imaging Centre School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, UK
2 shared publications
Latest Publications
- Open Access
- 30 October 2026
- Published by Springer Nature in Nature Communications
Real-time quantification of skeletal muscle metabolism in healthy men using hyperpolarised [1-¹³C]pyruvate reveals training-dependent adaptation
Skeletal muscle undergoes rapid and dynamic changes in energy demand during exercise, limiting the physiological relevance of resting-state measurements. Here, we demonstrate the feasibility of combining hyperpolarised ¹³C magnetic resonance spectroscopy (¹³C-MRS) with ³¹P-MRS to non-invasively measure real-time metabolic responses in exercising human skeletal muscle. Sedentary and endurance-trained men perform plantar-flexion exercise inside a magnetic resonance scanner. Dynamic hyperpolarised [1-¹³C]pyruvate spectra from the medial gastrocnemius show that increasing exercise intensity escalates pyruvate-to-lactate conversion relative to mitochondrial pyruvate utilisation. Endurance training is associated with greater bicarbonate labelling, consistent with increased mitochondrial pyruvate utilisation, and reduced lactate production. These metabolic signatures are accompanied by intensity- and training-dependent differences in phosphocreatine degradation and intracellular pH decline measured by ³¹P-MRS. Together, these findings demonstrate the feasibility of combining hyperpolarised ¹³C- and ³¹P-MRS to phenotype skeletal muscle metabolism during exercise, providing a platform for investigating metabolic adaptations in ageing, disease and therapeutic intervention.
- 30 October 2026
- Published by Springer Nature in Nature Communications
Open AccessReal-time quantification of skeletal muscle metabolism in healthy men using hyperpolarised [1-¹³C]pyruvate reveals training-dependent adaptation
Skeletal muscle undergoes rapid and dynamic changes in energy demand during exercise, limiting the physiological relevance of resting-state measurements. Here, we demonstrate the feasibility of combining hyperpolarised ¹³C magnetic resonance spectroscopy (¹³C-MRS) with ³¹P-MRS to non-invasively measure real-time metabolic responses in exercising human skeletal muscle. Sedentary and endurance-trained men perform plantar-flexion exercise inside a magnetic resonance scanner. Dynamic hyperpolarised [1-¹³C]pyruvate spectra from the medial gastrocnemius show that increasing exercise intensity escalates pyruvate-to-lactate conversion relative to mitochondrial pyruvate utilisation. Endurance training is associated with greater bicarbonate labelling, consistent with increased mitochondrial pyruvate utilisation, and reduced lactate production. These metabolic signatures are accompanied by intensity- and training-dependent differences in phosphocreatine degradation and intracellular pH decline measured by ³¹P-MRS. Together, these findings demonstrate the feasibility of combining hyperpolarised ¹³C- and ³¹P-MRS to phenotype skeletal muscle metabolism during exercise, providing a platform for investigating metabolic adaptations in ageing, disease and therapeutic intervention.
- Open Access
- 9 July 2025
- Published by Wiley in The Journal of Physiology
Co‐ingesting whey protein with dual‐source carbohydrate enhances amino acid availability without compromising post‐exercise liver glycogen resynthesis
We examined the effects of ingesting maltodextrin and/or fructose with protein co‐ingestion on post‐exercise liver and muscle glycogen resynthesis. Following glycogen‐depleting exercise, 10 well‐trained male cyclists ingested 60 g h−1 carbohydrate from either maltodextrin (MAL), fructose (FRU), 1:1 ratio of maltodextrin + fructose (MF) or 1:1 ratio of maltodextrin + fructose plus 30 g whey protein at 0 and 180 min (PRO) during a 5 h recovery period. 13C magnetic resonance spectroscopy and imaging were performed at 0, 120 and 300 min following exercise to determine liver and muscle glycogen concentrations and liver volume. Protein co‐ingestion resulted in elevated serum insulin and plasma glucagon compared with FRU and MF (P < 0.001 for all). Similarly, serum insulin and plasma glucagon concentrations were markedly higher with MAL when compared with both FRU and MF (P < 0.05 for all), although plasma glucagon was also higher when compared with PRO (P < 0.001). Liver glycogen concentrations were significantly higher with FRU (275 ± 49 mmol L−1), MF (255 ± 50 mmol L−1) and PRO (283 ± 50 mmol L−1) compared with MAL (204 ± 51 mmol L−1) (P < 0.05 for all) following 5 h of recovery. However, muscle glycogen concentrations (mmol L−1: MAL, 168 ± 33; FRU, 145 ± 32; MF, 151 ± 33; PRO 153 ± 33) were not different between trials (P > 0.05). We conclude that, despite enhancing glucagonaemia, co‐ingestion of whey protein (to a 1:1 combination of maltodextrin and fructose) does not compromise post‐exercise liver glycogen resynthesis, allowing for increased aminoacidaemia alongside rapid glycogen resynthesis. image Key points: Endurance athletes commonly co‐ingest carbohydrate and protein within the post‐exercise recovery period to facilitate rapid glycogen repletion and muscle remodelling. Here we report that the ingestion of dual‐source carbohydrate (a 1:1 ratio of maltodextrin and fructose) enhances liver glycogen repletion when compared with maltodextrin alone. Co‐ingesting whey protein alongside this dual‐source carbohydrate enhanced amino acid availability without compromising liver glycogen resynthesis, despite enhanced glucagonaemia. These data demonstrate that the co‐ingestion of whey protein with dual‐source carbohydrate provides a practical strategy to enhance amino acid availability (which provides an important substrate for post‐exercise muscle remodelling) and rapid glycogen resynthesis.
- 9 July 2025
- Published by Wiley in The Journal of Physiology
Open AccessCo‐ingesting whey protein with dual‐source carbohydrate enhances amino acid availability without compromising post‐exercise liver glycogen resynthesis
We examined the effects of ingesting maltodextrin and/or fructose with protein co‐ingestion on post‐exercise liver and muscle glycogen resynthesis. Following glycogen‐depleting exercise, 10 well‐trained male cyclists ingested 60 g h−1 carbohydrate from either maltodextrin (MAL), fructose (FRU), 1:1 ratio of maltodextrin + fructose (MF) or 1:1 ratio of maltodextrin + fructose plus 30 g whey protein at 0 and 180 min (PRO) during a 5 h recovery period. 13C magnetic resonance spectroscopy and imaging were performed at 0, 120 and 300 min following exercise to determine liver and muscle glycogen concentrations and liver volume. Protein co‐ingestion resulted in elevated serum insulin and plasma glucagon compared with FRU and MF (P < 0.001 for all). Similarly, serum insulin and plasma glucagon concentrations were markedly higher with MAL when compared with both FRU and MF (P < 0.05 for all), although plasma glucagon was also higher when compared with PRO (P < 0.001). Liver glycogen concentrations were significantly higher with FRU (275 ± 49 mmol L−1), MF (255 ± 50 mmol L−1) and PRO (283 ± 50 mmol L−1) compared with MAL (204 ± 51 mmol L−1) (P < 0.05 for all) following 5 h of recovery. However, muscle glycogen concentrations (mmol L−1: MAL, 168 ± 33; FRU, 145 ± 32; MF, 151 ± 33; PRO 153 ± 33) were not different between trials (P > 0.05). We conclude that, despite enhancing glucagonaemia, co‐ingestion of whey protein (to a 1:1 combination of maltodextrin and fructose) does not compromise post‐exercise liver glycogen resynthesis, allowing for increased aminoacidaemia alongside rapid glycogen resynthesis. image Key points: Endurance athletes commonly co‐ingest carbohydrate and protein within the post‐exercise recovery period to facilitate rapid glycogen repletion and muscle remodelling. Here we report that the ingestion of dual‐source carbohydrate (a 1:1 ratio of maltodextrin and fructose) enhances liver glycogen repletion when compared with maltodextrin alone. Co‐ingesting whey protein alongside this dual‐source carbohydrate enhanced amino acid availability without compromising liver glycogen resynthesis, despite enhanced glucagonaemia. These data demonstrate that the co‐ingestion of whey protein with dual‐source carbohydrate provides a practical strategy to enhance amino acid availability (which provides an important substrate for post‐exercise muscle remodelling) and rapid glycogen resynthesis.
- Open Access
- 11 June 2025
- Published by Springer Nature
How the menstrual cycle affects energy use during exercise
- 11 June 2025
- Published by Springer Nature
Open AccessHow the menstrual cycle affects energy use during exercise
- Open Access
- 31 August 2023
- Published by Wiley in NMR in Biomedicine
- Vol. 37 (1) , e5032
The impact of variations in subject geometry, respiration and coil repositioning on the specific absorption rate in parallel transmit abdominal imaging at 7 T
Parallel transmit MRI at 7 T has increasingly been adopted in research projects and provides increased signal‐to‐noise ratios and novel contrasts. However, the interactions of fields in the body need to be carefully considered to ensure safe scanning. Recent advances in physically flexible body coils have allowed for high‐field abdominal imaging, but the effects of increased variability on energy deposition need further exploration. The aim of this study was to assess the impact of subject geometry, respiration phase and coil positioning on the specific absorption rate (SAR). Ten healthy subjects (body mass index [BMI] = 25 ± 5 kg m−2) were scanned (at 3 T) during exhale breath‐hold and images used to generate body models. Seven of these subjects were also scanned during inhale. Simplifications of the coil and body models were first explored, and then finite‐difference time‐domain simulations were run with a typical eight‐channel parallel transmit coil positioned over the abdomen. Simulations were used to generate 10 g averaged SAR (SAR10g) maps across 100,000 phase settings, and the worst‐case scenario 10 g averaged SAR (wocSAR10g) was identified using trigonometric maximisation. The average maximum SAR10g across the 10 subjects with 1 W input power per channel was 1.77 W kg−1. Hotspots were always close to the body surface near the muscle wall boundary. The wocSAR10g across the 10 subjects ranged from 2.3 to 3.2 W kg−1 and was inversely correlated to fat volume percentage (R = 8) and BMI (R = 0.6). The coefficient of variation values in SAR10g due to variations in subject geometry, respiration phase and realistic coil repositioning were 12%, 4% and 12%, respectively. This study found that the variability due to realistic coil repositioning was similar to the variability due to differing healthy subject geometries for abdominal imaging. This is important as it suggests that population‐based modelling is likely to be more useful than individual modelling in setting safe thresholds for abdominal imaging.
- 31 August 2023
- Published by Wiley in NMR in Biomedicine
- Vol. 37 (1) , e5032
Open AccessThe impact of variations in subject geometry, respiration and coil repositioning on the specific absorption rate in parallel transmit abdominal imaging at 7 T
Parallel transmit MRI at 7 T has increasingly been adopted in research projects and provides increased signal‐to‐noise ratios and novel contrasts. However, the interactions of fields in the body need to be carefully considered to ensure safe scanning. Recent advances in physically flexible body coils have allowed for high‐field abdominal imaging, but the effects of increased variability on energy deposition need further exploration. The aim of this study was to assess the impact of subject geometry, respiration phase and coil positioning on the specific absorption rate (SAR). Ten healthy subjects (body mass index [BMI] = 25 ± 5 kg m−2) were scanned (at 3 T) during exhale breath‐hold and images used to generate body models. Seven of these subjects were also scanned during inhale. Simplifications of the coil and body models were first explored, and then finite‐difference time‐domain simulations were run with a typical eight‐channel parallel transmit coil positioned over the abdomen. Simulations were used to generate 10 g averaged SAR (SAR10g) maps across 100,000 phase settings, and the worst‐case scenario 10 g averaged SAR (wocSAR10g) was identified using trigonometric maximisation. The average maximum SAR10g across the 10 subjects with 1 W input power per channel was 1.77 W kg−1. Hotspots were always close to the body surface near the muscle wall boundary. The wocSAR10g across the 10 subjects ranged from 2.3 to 3.2 W kg−1 and was inversely correlated to fat volume percentage (R = 8) and BMI (R = 0.6). The coefficient of variation values in SAR10g due to variations in subject geometry, respiration phase and realistic coil repositioning were 12%, 4% and 12%, respectively. This study found that the variability due to realistic coil repositioning was similar to the variability due to differing healthy subject geometries for abdominal imaging. This is important as it suggests that population‐based modelling is likely to be more useful than individual modelling in setting safe thresholds for abdominal imaging.
- Open Access
- 20 December 2022
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 36 (4) , 553-563
Comparing magnetic resonance liver fat fraction measurements with histology in fibrosis: the difference between proton density fat fraction and tissue mass fat fraction
Objective Magnetic resonance spectroscopy (MRS) provides a powerful method of measuring fat fraction. However, previous studies have shown that MRS results give lower values compared with visual estimates from biopsies in fibrotic livers. This study investigated these discrepancies and considered whether a tissue water content correction, as assessed by MRI relaxometry, could provide better agreement. Materials and methods 110 patients were scanned in a 1.5 T Philips scanner and biopsies were obtained. Multiple echo MRS (30 × 30 × 30 mm volume) was used to determine Proton Density Fat Fraction (PDFF). Biopsies were assessed by visual assessment for fibrosis and steatosis grading. Digital image analysis (DIA) was also used to quantify fat fraction within tissue samples. T1 relaxation times were then used to estimate tissue water content to correct PDFF for confounding factors. Results PDFF values across the four visually assessed steatosis grades were significantly less in the higher fibrosis group (F3–F4) compared to the lower fibrosis group (F0–F2). The slope of the linear regression of PDFF vs DIA fat fraction was ~ 1 in the low fibrosis group and 0.77 in the high fibrosis group. Correcting for water content based on T1 increased the gradient but it did not reach unity. Discussion In fibrotic livers, PDFF underestimated fat fraction compared to DIA methods. Values were improved by applying a water content correction, but fat fractions were still underestimated.
- 20 December 2022
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 36 (4) , 553-563
Open AccessComparing magnetic resonance liver fat fraction measurements with histology in fibrosis: the difference between proton density fat fraction and tissue mass fat fraction
Objective Magnetic resonance spectroscopy (MRS) provides a powerful method of measuring fat fraction. However, previous studies have shown that MRS results give lower values compared with visual estimates from biopsies in fibrotic livers. This study investigated these discrepancies and considered whether a tissue water content correction, as assessed by MRI relaxometry, could provide better agreement. Materials and methods 110 patients were scanned in a 1.5 T Philips scanner and biopsies were obtained. Multiple echo MRS (30 × 30 × 30 mm volume) was used to determine Proton Density Fat Fraction (PDFF). Biopsies were assessed by visual assessment for fibrosis and steatosis grading. Digital image analysis (DIA) was also used to quantify fat fraction within tissue samples. T1 relaxation times were then used to estimate tissue water content to correct PDFF for confounding factors. Results PDFF values across the four visually assessed steatosis grades were significantly less in the higher fibrosis group (F3–F4) compared to the lower fibrosis group (F0–F2). The slope of the linear regression of PDFF vs DIA fat fraction was ~ 1 in the low fibrosis group and 0.77 in the high fibrosis group. Correcting for water content based on T1 increased the gradient but it did not reach unity. Discussion In fibrotic livers, PDFF underestimated fat fraction compared to DIA methods. Values were improved by applying a water content correction, but fat fractions were still underestimated.
- Open Access
- 7 February 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (4) , 632
Metabolic Imaging in Non-Alcoholic Fatty Liver Disease: Applications of Magnetic Resonance Spectroscopy
Non-alcoholic fatty liver disease (NAFLD) is poised to dominate the landscape of clinical hepatology in the 21st century. Its complex, interdependent aetiologies, non-linear disease progression and uncertain natural history have presented great challenges to the development of effective therapies. Progress will require an integrated approach to uncover molecular mediators, key pathogenic milestones and response to intervention at the metabolic level. The advent of precision imaging has yielded unprecedented insights into these processes. Quantitative imaging biomarkers such as magnetic resonance imaging (MRI), spectroscopy (MRS) and elastography (MRE) present robust, powerful tools with which to probe NAFLD metabolism and fibrogenesis non-invasively, in real time. Specific advantages of MRS include the ability to quantify static metabolite concentrations as well as dynamic substrate flux in vivo. Thus, a vast range of key metabolic events in the natural history of NAFLD can be explored using MRS. Here, we provide an overview of MRS for the clinician, as well as key pathways exploitable by MRS in vivo. Development, optimisation and validation of multinuclear MRS, in combination with other quantitative imaging techniques, may ultimately provide a robust, non-invasive alternative to liver biopsy for observational and longitudinal studies. Through enabling deeper insight into inflammatory and fibrogenic cascades, MRS may facilitate identification of novel therapeutic targets and clinically meaningful endpoints in NAFLD. Its widespread use in future could conceivably accelerate study design, data acquisition and availability of disease-modifying therapies at a population level.
- 7 February 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (4) , 632
Open AccessMetabolic Imaging in Non-Alcoholic Fatty Liver Disease: Applications of Magnetic Resonance Spectroscopy
Non-alcoholic fatty liver disease (NAFLD) is poised to dominate the landscape of clinical hepatology in the 21st century. Its complex, interdependent aetiologies, non-linear disease progression and uncertain natural history have presented great challenges to the development of effective therapies. Progress will require an integrated approach to uncover molecular mediators, key pathogenic milestones and response to intervention at the metabolic level. The advent of precision imaging has yielded unprecedented insights into these processes. Quantitative imaging biomarkers such as magnetic resonance imaging (MRI), spectroscopy (MRS) and elastography (MRE) present robust, powerful tools with which to probe NAFLD metabolism and fibrogenesis non-invasively, in real time. Specific advantages of MRS include the ability to quantify static metabolite concentrations as well as dynamic substrate flux in vivo. Thus, a vast range of key metabolic events in the natural history of NAFLD can be explored using MRS. Here, we provide an overview of MRS for the clinician, as well as key pathways exploitable by MRS in vivo. Development, optimisation and validation of multinuclear MRS, in combination with other quantitative imaging techniques, may ultimately provide a robust, non-invasive alternative to liver biopsy for observational and longitudinal studies. Through enabling deeper insight into inflammatory and fibrogenic cascades, MRS may facilitate identification of novel therapeutic targets and clinically meaningful endpoints in NAFLD. Its widespread use in future could conceivably accelerate study design, data acquisition and availability of disease-modifying therapies at a population level.
- Open Access
Calibration-free regional RF shims for MR spectroscopy
Purpose: Sufficient control of the RF transmit field (B 1 + ) in small regions-of-interest (ROIs) is critical for single voxel MR spectroscopy at ultra-high field. Static RF shimming, using parallel transmit (pTx), can improve B 1 + , but must be calibrated for each participant and ROI, which limits its applicability. Additionally, specific-absorption-rate (SAR) becomes hard to predict. This work aimed to find RF shims, which can be applied to any participant, to produce the desired |B 1 + | within pre-defined target ROIs. Methods: RF shims were found offline by joint-optimisation on a database, comprising B 1 + maps from 11 subjects, considering ROIs in occipital cortex, hippocampus and posterior-cingulate, as well as the whole brain. The B 1 + magnitude achieved using calibration-free RF shims was compared to a tailored shimming approach, and MR spectra were acquired using tailored and calibration-free RF shimming in 4 participants. Global and local 10g SAR deposition were modelled. Results: Calibration-free RF shims resulted in similar |B 1 + | in small ROIs compared to tailored shimming, in addition to producing spectra of excellent quality and equivalent SNR. Only a small database size was required. SAR deposition was reduced compared to operating in quadrature mode for all ROIs. Conclusion: This work demonstrates that static RF shims, optimised offline for small regions in single voxel MRS, avoid the need for lengthy B 1 + mapping and pTx optimisation for each ROI and participant. Furthermore, power settings may be increased when using calibration-free shims to better take advantage of the flexibility provided by RF shimming for regional acquisition at ultra-high field.
Open AccessCalibration-free regional RF shims for MR spectroscopy
Purpose: Sufficient control of the RF transmit field (B 1 + ) in small regions-of-interest (ROIs) is critical for single voxel MR spectroscopy at ultra-high field. Static RF shimming, using parallel transmit (pTx), can improve B 1 + , but must be calibrated for each participant and ROI, which limits its applicability. Additionally, specific-absorption-rate (SAR) becomes hard to predict. This work aimed to find RF shims, which can be applied to any participant, to produce the desired |B 1 + | within pre-defined target ROIs. Methods: RF shims were found offline by joint-optimisation on a database, comprising B 1 + maps from 11 subjects, considering ROIs in occipital cortex, hippocampus and posterior-cingulate, as well as the whole brain. The B 1 + magnitude achieved using calibration-free RF shims was compared to a tailored shimming approach, and MR spectra were acquired using tailored and calibration-free RF shimming in 4 participants. Global and local 10g SAR deposition were modelled. Results: Calibration-free RF shims resulted in similar |B 1 + | in small ROIs compared to tailored shimming, in addition to producing spectra of excellent quality and equivalent SNR. Only a small database size was required. SAR deposition was reduced compared to operating in quadrature mode for all ROIs. Conclusion: This work demonstrates that static RF shims, optimised offline for small regions in single voxel MRS, avoid the need for lengthy B 1 + mapping and pTx optimisation for each ROI and participant. Furthermore, power settings may be increased when using calibration-free shims to better take advantage of the flexibility provided by RF shimming for regional acquisition at ultra-high field.
- 29 September 2016
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 19 (1) , 70-77
Increased liver fat and glycogen stores after consumption of high versus low glycaemic index food: A randomized crossover study
Aim: To investigate the acute and longer‐term effects of low ( LGI ) versus high glycaemic index ( HGI ) diets on hepatic fat and glycogen accumulation and related blood measures in healthy volunteers. Methods: Eight healthy men (age 20.1 ± 0.4 years, body mass index 23.0 ± 0.9 kg/m 2 ) attended a test day before and after a 7‐day macronutrient‐ and energy‐matched HGI or LGI diet, followed by a minimum 4‐week wash‐out period, and then returned to repeat the intervention with the alternative diet. During test days, participants consumed either an HGI or an LGI test meal corresponding to their diet week, and liver fat [ 1 H magnetic resonance spectroscopy ( MRS )], glycogen ( 13 C MRS ) and gastric content volume ( MRI ) were measured. Blood samples were obtained regularly throughout the test day to assess plasma glucose and insulin levels. Results: Plasma glucose and insulin peak values and area under the curve were significantly greater after the HGI test meal compared with the LGI test meal, as expected. Hepatic glycogen concentrations increased more after the HGI test meal ( P < .05) and peak levels were significantly greater after 7 days of HGI dietary intervention compared with those at the beginning of the intervention ( P < .05). Liver fat fractions increased significantly after the HGI dietary intervention compared with the LGI dietary intervention (two‐way repeated‐measures analysis of variance P ≤ .05). Conclusions: Compared with an LGI diet, a 1‐week HGI diet increased hepatic fat and glycogen stores. This may have important clinical relevance for dietary interventions in the prevention and management of non‐alcoholic fatty liver disease.
- 29 September 2016
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 19 (1) , 70-77
Increased liver fat and glycogen stores after consumption of high versus low glycaemic index food: A randomized crossover study
Aim: To investigate the acute and longer‐term effects of low ( LGI ) versus high glycaemic index ( HGI ) diets on hepatic fat and glycogen accumulation and related blood measures in healthy volunteers. Methods: Eight healthy men (age 20.1 ± 0.4 years, body mass index 23.0 ± 0.9 kg/m 2 ) attended a test day before and after a 7‐day macronutrient‐ and energy‐matched HGI or LGI diet, followed by a minimum 4‐week wash‐out period, and then returned to repeat the intervention with the alternative diet. During test days, participants consumed either an HGI or an LGI test meal corresponding to their diet week, and liver fat [ 1 H magnetic resonance spectroscopy ( MRS )], glycogen ( 13 C MRS ) and gastric content volume ( MRI ) were measured. Blood samples were obtained regularly throughout the test day to assess plasma glucose and insulin levels. Results: Plasma glucose and insulin peak values and area under the curve were significantly greater after the HGI test meal compared with the LGI test meal, as expected. Hepatic glycogen concentrations increased more after the HGI test meal ( P < .05) and peak levels were significantly greater after 7 days of HGI dietary intervention compared with those at the beginning of the intervention ( P < .05). Liver fat fractions increased significantly after the HGI dietary intervention compared with the LGI dietary intervention (two‐way repeated‐measures analysis of variance P ≤ .05). Conclusions: Compared with an LGI diet, a 1‐week HGI diet increased hepatic fat and glycogen stores. This may have important clinical relevance for dietary interventions in the prevention and management of non‐alcoholic fatty liver disease.
- 1 June 2016
- Published by Elsevier in Clinical Nutrition
- Vol. 35 (3) , 645-649
Investigating the effects of an oral fructose challenge on hepatic ATP reserves in healthy volunteers: A 31P MRS study
- 1 June 2016
- Published by Elsevier in Clinical Nutrition
- Vol. 35 (3) , 645-649
Investigating the effects of an oral fructose challenge on hepatic ATP reserves in healthy volunteers: A 31P MRS study
- 1 April 2015
- Published by Elsevier in Journal of Hepatology
- Vol. 62, S713
P0978 : A 7 day low vs high glycaemic index diet reduces liver fat content in healthy subjects: A 1H MRS study
- 1 April 2015
- Published by Elsevier in Journal of Hepatology
- Vol. 62, S713
P0978 : A 7 day low vs high glycaemic index diet reduces liver fat content in healthy subjects: A 1H MRS study